{"product_id":"ram-m400-ram-m800-confocal-raman-microscope","title":"Research Confocal Raman Microscope","description":"\u003c!-- ============================================================\n     NWSPEC Ram-M400 \/ Ram-M800 — Research Confocal Raman Microscope\n     Application-first product guide (real-world scenarios first)\n     ============================================================ --\u003e\n\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; max-width: 900px; margin: 0 auto; color: #111111; line-height: 1.6; font-size: 16px;\"\u003e\n\u003c!-- Header Block --\u003e\n\u003cdiv style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 14px; margin-bottom: 20px;\"\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin: 0 0 8px 0; color: #111827;\"\u003eRam-M400 \/ Ram-M800 Research Confocal Raman Microscope\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #4b5563; font-size: 16px;\"\u003eFlagship confocal Raman platform for materials research, 2D materials and phonon physics, pharmaceutical polymorphism, operando batteries, label-free bio-imaging, and cultural-heritage analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Quick-Spec Hero Bar --\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 12px; margin-bottom: 28px;\"\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; padding: 14px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 12px; font-weight: 600; color: #64748b; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 4px;\"\u003eSpectral Resolution\u003c\/div\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold; color: #0f172a;\"\u003e\u0026lt; 0.5 cm⁻¹\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #475569; margin-top: 2px;\"\u003e0.02 cm⁻¹ repeatability (M800)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; padding: 14px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 12px; font-weight: 600; color: #64748b; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 4px;\"\u003eExcitation Lasers\u003c\/div\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold; color: #0f172a;\"\u003eUp to 4 Lasers\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #475569; margin-top: 2px;\"\u003e213–1064 nm auto-switching\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; padding: 14px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 12px; font-weight: 600; color: #64748b; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 4px;\"\u003eLow-Wavenumber Cutoff\u003c\/div\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold; color: #0f172a;\"\u003e±5 cm⁻¹\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #475569; margin-top: 2px;\"\u003eSimultaneous Stokes \/ Anti-Stokes\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; padding: 14px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 12px; font-weight: 600; color: #64748b; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 4px;\"\u003eConfocal Optics\u003c\/div\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold; color: #0f172a;\"\u003eTrue Pinhole + Slit\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #475569; margin-top: 2px;\"\u003e15–2000 µm continuous control\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Application Scenarios First --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eReal-World Application Scenarios\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 12px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #e5e7eb;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f8fafc; color: #111827;\"\u003e\n\u003cth style=\"padding: 10px 12px; text-align: left; border: 1px solid #e5e7eb; font-weight: 600; width: 26%;\"\u003eScenario\u003c\/th\u003e\n\u003cth style=\"padding: 10px 12px; text-align: left; border: 1px solid #e5e7eb; font-weight: 600; width: 38%;\"\u003eWhat You Are Trying to Do\u003c\/th\u003e\n\u003cth style=\"padding: 10px 12px; text-align: left; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eHow Ram-M400 \/ M800 Solves It\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003e2D materials \u0026amp; strain engineering\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eResolve adjacent phonon modes in graphene, MoS₂, h-BN; map strain at sub-cm⁻¹ level.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003e0.5 cm⁻¹ class resolution (M800) with 0.02 cm⁻¹ repeatability separates peaks that ordinary microscopes merge.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eLattice \/ low-frequency modes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eMeasure shear and breathing modes close to the laser line.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eUltra-low wavenumber module records Stokes \/ anti-Stokes simultaneously down to a ±5 cm⁻¹ cutoff.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003ePharmaceutical polymorphism\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eDistinguish crystal forms, confirm salt formation, check tablet uniformity.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eTrue confocal pinhole + slit (15–2000 µm) isolates pure material; Raman \/ fluorescence \/ absorption imaging maps the whole surface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eOperando batteries \u0026amp; electrochemistry\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eWatch electrodes and SEI evolve inside a working cell.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003e3-electrode electrochemical cell (upright \/ vertical) plus heating-cooling stage (−15 to +55 °C) for in-situ Raman.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eTERS \u0026amp; nanoscale Raman\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003ePush below the diffraction limit with an AFM tip.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eDetachable fiber TERS probe with built-in coaxial video couples to mainstream AFMs; platform is TERS-ready by design.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eFluorescent \/ coloured samples\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eGet clean Raman from samples that swamp 532 nm systems.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eUp to 4 lasers chosen from 213–1064 nm with automatic filter switching — pick 633\/785\/1064 nm to defeat fluorescence.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Why it fits --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eWhy It Fits Your Laboratory\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; color: #374151; margin: 0 0 12px 0;\"\u003eThe Ram-M400 and Ram-M800 represent NWSPEC's research-flagship tier: longer focal length, more lasers, deeper detector cooling, and a true pinhole + slit confocal path. Choose \u003cb\u003eRam-M400\u003c\/b\u003e for \u0026lt;0.8 cm⁻¹ resolution on a standard optical bench, or \u003cb\u003eRam-M800\u003c\/b\u003e when only \u0026lt;0.5 cm⁻¹ ultra-high resolution satisfies advanced phonon physics. Both share the same software, stages, and extension modules so accessories transfer across your laboratory.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Build Your Configuration — 3 Decisions --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eBuild Your Configuration — 3 Key Decisions\u003c\/h3\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; background: #f8fafc; padding: 16px; border-radius: 4px; margin-bottom: 14px;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; font-size: 15px; font-weight: bold; color: #111827;\"\u003eDecision 1 — Spectrometer Base: M400 vs. M800\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; background: #ffffff; border: 1px solid #e5e7eb;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f1f5f9; color: #111827;\"\u003e\n\u003cth style=\"padding: 8px 10px; border: 1px solid #e5e7eb; text-align: left;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 8px 10px; border: 1px solid #e5e7eb; text-align: left;\"\u003eFocal Length\u003c\/th\u003e\n\u003cth style=\"padding: 8px 10px; border: 1px solid #e5e7eb; text-align: left;\"\u003eResolution\u003c\/th\u003e\n\u003cth style=\"padding: 8px 10px; border: 1px solid #e5e7eb; text-align: left;\"\u003eRecommended For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eRam-M400\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e400 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e\u0026lt; 0.8 cm⁻¹\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003ePharmaceutical, polymer and standard materials QC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f8fafc;\"\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eRam-M800\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e800 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e\u0026lt; 0.5 cm⁻¹\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e2D materials, phonon physics, closely spaced vibrational peaks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; background: #f8fafc; padding: 16px; border-radius: 4px; margin-bottom: 14px;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; font-size: 15px; font-weight: bold; color: #111827;\"\u003eDecision 2 — Laser Bay (Up to 4 Lasers)\u003c\/h4\u003e\n\u003cp style=\"font-size: 14px; margin: 0 0 8px 0; color: #374151;\"\u003eSelect up to 4 ultra-narrow-linewidth lasers from 213, 244, 257, 355, 405, 488, 532, 633, 785, 830, 850, and 1064 nm. Edge-filter sets switch automatically in software without manual optical alignment.\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px; font-size: 14px; color: #4b5563;\"\u003e\n\u003cli\u003e\n\u003cb\u003eMaterials \u0026amp; 2D:\u003c\/b\u003e 532 nm + 633 nm (add 785 nm for fluorescent substrates)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePharma \u0026amp; Biological:\u003c\/b\u003e 785 nm (fluorescence suppression) + 532 nm reference\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUV Photoluminescence:\u003c\/b\u003e 355 nm or 405 nm UV configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; background: #f8fafc; padding: 16px; border-radius: 4px;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; font-size: 15px; font-weight: bold; color: #111827;\"\u003eDecision 3 — Detector Cooling \u0026amp; Specialized Modules\u003c\/h4\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #374151;\"\u003eChoose deep-cooled TEC CCD at −70 °C (air-cooled) or −100 °C (water-cooled) for ultra-low dark noise. Add optional extensions: ultra-low wavenumber module (±5 cm⁻¹ cutoff), operando 3-electrode electrochemical cell, heating\/cooling stage (−15 to +55 °C), or fiber TERS probe for AFM integration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Key Specifications --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 12px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #e5e7eb;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\"\u003eFocal length\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eRam-M400: 400 mm · Ram-M800: 800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eSpectral resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003e\u0026lt; 0.8 cm⁻¹ (M400) · \u0026lt; 0.5 cm⁻¹ (M800); repeatability 0.02 cm⁻¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eGratings\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eUp to 4 mounted, 150–4964 g\/mm options, motorized switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eSpectral range\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eRaman shift 50–9700 cm⁻¹; detector response 200–1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eUltra-low wavenumber\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eStokes \/ anti-Stokes simultaneous, down to ±5 cm⁻¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eExcitation lasers\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eUp to 4 narrow-linewidth lasers (213–1064 nm); stability ≤0.24% RMS \/ 4h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eConfocal optics\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eTrue confocal pinhole + entrance slit, 15–2000 µm continuously adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eTEC deep-cooled CCD (−70 °C air \/ −100 °C water); Si 3rd-order SNR \u0026gt;30:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eSample stage\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eMotorized XYZ, 75 × 50 × 30 mm, 0.5 µm repeatability, 50 nm step, auto-focus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eMicroscope\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eUpright reflected brightfield; 5× \/ 10× \/ 20× \/ 50× LWD \/ 100× plan-achromatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eSoftware\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eRaman\/fluorescence\/absorption imaging, auto-baseline removal, spectral library search\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"margin-bottom: 12px;\"\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 4px 0; font-weight: bold; color: #111827;\"\u003eWhich model do I need — Ram-M400 or Ram-M800?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #4b5563;\"\u003eFor routine high-resolution work (polymorph ID, materials QC), the M400 is ideal. If you analyze 2D materials, strain, or phonon physics where peaks sit less than 1 cm⁻¹ apart, choose the M800 for its 800 mm focal length and \u0026lt;0.5 cm⁻¹ resolution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 12px;\"\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 4px 0; font-weight: bold; color: #111827;\"\u003eHow many lasers can be installed, and can I add more later?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #4b5563;\"\u003eThe optical bay accepts up to 4 lasers selected from 12 wavelengths, with automated software switching. The laser package is pre-configured during manufacturing to ensure perfect optical alignment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 12px;\"\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 4px 0; font-weight: bold; color: #111827;\"\u003eHow low in wavenumber can the system measure?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #4b5563;\"\u003eWith the ultra-low wavenumber filter module, the system records Stokes and anti-Stokes scattering simultaneously down to a ±5 cm⁻¹ cutoff, ideal for lattice, shear, and breathing modes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 4px 0; font-weight: bold; color: #111827;\"\u003eCan it support in-situ electrochemistry or AFM-TERS?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #4b5563;\"\u003eYes. A 3-electrode upright\/vertical electrochemical cell with temperature control (−15 to +55 °C) supports operando battery research, and a detachable fiber TERS probe connects directly to mainstream AFMs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Quote Callout Box --\u003e\n\u003cdiv style=\"border: 1px solid #cbd5e1; padding: 20px; background: #f8fafc; border-radius: 4px; margin-top: 24px;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; font-size: 16px; font-weight: bold; color: #111827;\"\u003eGet a Configuration Recommendation \u0026amp; Quote\u003c\/h4\u003e\n\u003cp style=\"margin: 0; font-size: 14px; color: #334155; line-height: 1.5;\"\u003eTell us your research application, laser wavelengths (from 213–1064 nm) and extension modules. NWSPEC will configure your Ram-M400 or Ram-M800 platform and provide a comprehensive quotation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":51270281658587,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/M400_confocal_Raman_Microscope.png?v=1795683541","url":"https:\/\/nwspec.com\/ar\/products\/ram-m400-ram-m800-confocal-raman-microscope","provider":"NWSPEC","version":"1.0","type":"link"}