{"product_id":"s10-tga-gc-ms-multi-loop-sampler","title":"S10 TGA-GC\/MS Multi-Loop Sampler","description":"\u003c!-- S10 TGA-GC\/MS Auto-Sampler - GC SAMPLE INTRODUCTION ACCESSORY --\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"breadcrumb\"\u003e\n\u003cspan\u003eGC Systems\u003c\/span\u003e \u0026gt; \u003cspan\u003eSample Introduction\u003c\/span\u003e \u0026gt; \u003cstrong\u003eS10 Auto-Sampler\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003ch1\u003eS10 TGA-GC\/MS Auto-Sampler\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eAutomated Sample Introduction from Thermogravimetry to GC-MS | NWSPEC GC Accessory Series\u003c\/p\u003e\n\u003cdiv class=\"badge\"\u003eAUTO-SAMPLER\u003c\/div\u003e\n\u003cdiv class=\"highlights\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eS10\u003c\/strong\u003e is an automated sample introduction accessory that captures time-resolved gas evolved from thermogravimetric analyzers (TGA) and feeds stored samples sequentially into GC-MS for analysis. It solves the fundamental timing mismatch between rapid TGA weight-loss events and slower GC-MS analysis cycles.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"problem-box\"\u003e\n\u003ch3\u003eProblem Solved by S10\u003c\/h3\u003e\n\u003cp\u003eIn traditional TGA-GC-MS setups, users can only inject one sample per TGA run. By the time GC-MS analysis completes, the TGA thermal event is already over—preventing multiple sampling. The S10 auto-sampler captures up to 16 time-resolved samples automatically and introduces them sequentially into the GC-MS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eGC-MS Applications\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003eRubber and polymer thermal degradation analysis\u003c\/li\u003e\n\u003cli\u003eCO2 emission profiling during material heating\u003c\/li\u003e\n\u003cli\u003eVolatile organic compound evolution tracking\u003c\/li\u003e\n\u003cli\u003ePharmaceutical thermal stability studies\u003c\/li\u003e\n\u003cli\u003eCoal and biomass pyrolysis gas analysis\u003c\/li\u003e\n\u003cli\u003eFTIR medium gas bypass analysis supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eAuto-Sampler Features\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-sample capacity:\u003c\/strong\u003e Up to 16 quantitative sample loops for batch analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic trapping:\u003c\/strong\u003e Sample gas captured in loops per programmed schedule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSequential injection:\u003c\/strong\u003e Stored samples introduced into GC-MS one by one\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware-configurable timing:\u003c\/strong\u003e Sampling intervals set per TGA heating program\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated gas sampling valve:\u003c\/strong\u003e Built-in GSV—no GC-end configuration needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-play inlet:\u003c\/strong\u003e 1\/32\" inert tube inserts into standard GC S\/SL port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero GC modification:\u003c\/strong\u003e No changes required to injection port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal mounting bracket:\u003c\/strong\u003e Compatible with mainstream GC-MS systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated valve box:\u003c\/strong\u003e All valves and loops heated up to 300°C (max 330°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInert treatment:\u003c\/strong\u003e All sample tubes treated to prevent adsorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConcentration curves:\u003c\/strong\u003e Component trend export via chromatograph software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBypass to FTIR:\u003c\/strong\u003e Parallel connection to infrared analyzer supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eAuto-Sampler Specifications\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Valve Box Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Loops:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\/10\/12\/16 (standard: 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Valves:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (sampling, injection, isolation - Vici)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Volume:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250μL (optional 500μL, 1mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Line Max Temp:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Line:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInert treated stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220Vac, 5 amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarrier Gas:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir @ 4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeakage Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 × 10⁻⁸ atm-cc\/sec He\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470H × 230W × 430L mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect via browser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMethod Setting:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGC interface or PC software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\" Swagelok\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, RS485, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouchscreen:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\" integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eCompatible GC-MS Systems\u003c\/h2\u003e\n\u003cdiv class=\"compat-grid\"\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eAgilent\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eGC-MSD Series\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eThermo Fisher\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eISQ \/ TSQ Series\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eShimadzu\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eGCMS-QP Series\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eNWSPEC GC60\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWith MS Module\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"integration\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e The S10 auto-sampler acts as a time-resolved sampling bridge between TGA and GC-MS. Users program sampling intervals matching their TGA heating ramp. The S10 automatically stores evolved gases and feeds them sequentially to the GC-MS—enabling complete thermal profile analysis that was previously impossible with single-injection setups.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta\"\u003e\n\u003cspan style=\"color: rgb(255, 255, 255);\"\u003e\u003ca class=\"btn\" href=\"\/ar\/pages\/contact\" style=\"color: rgb(255, 255, 255);\"\u003eRequest Auto-Sampler Quote\u003c\/a\u003e\u003c\/span\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-container {\n  max-width: 900px;\n  margin: 0 auto;\n  padding: 40px 20px;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n  font-size: 14px;\n  line-height: 1.6;\n  color: #222;\n  background: #fff;\n}\n\n.breadcrumb {\n  font-size: 13px;\n  color: #666;\n  margin-bottom: 20px;\n  padding: 10px 0;\n  border-bottom: 1px solid #eee;\n}\n.breadcrumb span { color: #999; }\n.breadcrumb strong { color: #000; }\n\nh1 {\n  font-size: 36px;\n  font-weight: 700;\n  color: #000;\n  margin: 0 0 10px 0;\n  letter-spacing: -1px;\n}\n\n.subtitle {\n  font-size: 16px;\n  color: #555;\n  margin: 0 0 15px 0;\n  font-weight: 400;\n}\n\n.badge {\n  display: inline-block;\n  background: #000;\n  color: #fff;\n  padding: 6px 20px;\n  font-size: 12px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin-bottom: 30px;\n}\n\n.highlights {\n  background: #f5f5f5;\n  padding: 25px 30px;\n  margin: 30px 0;\n  border-left: 4px solid #000;\n  font-size: 15px;\n  line-height: 1.7;\n}\n.highlights p { margin: 0; }\n\n.problem-box {\n  background: #fff;\n  padding: 25px 30px;\n  margin: 20px 0;\n  border: 2px solid #000;\n}\n.problem-box h3 {\n  margin: 0 0 15px 0;\n  font-size: 16px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n.problem-box p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n\n.section-title {\n  font-size: 22px;\n  font-weight: 700;\n  color: #000;\n  margin: 50px 0 25px 0;\n  padding-bottom: 12px;\n  border-bottom: 3px solid #000;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.feature-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.feature-list li {\n  padding: 12px 0 12px 25px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n  line-height: 1.6;\n  position: relative;\n}\n.feature-list li::before {\n  content: \"—\";\n  position: absolute;\n  left: 0;\n  color: #000;\n  font-weight: bold;\n}\n\n.specs-table {\n  width: 100%;\n  border-collapse: collapse;\n  margin-top: 20px;\n}\n.specs-table td {\n  padding: 12px 15px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n}\n.specs-table td:first-child {\n  width: 45%;\n  color: #000;\n  font-weight: 600;\n}\n\n.compat-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 20px;\n  margin-top: 20px;\n}\n.compat-item {\n  background: #fff;\n  padding: 20px;\n  border: 2px solid #000;\n  text-align: center;\n}\n.compat-item strong {\n  font-size: 16px;\n  display: block;\n  margin-bottom: 5px;\n}\n.compat-item span {\n  font-size: 13px;\n  color: #555;\n}\n\n.integration {\n  background: #000;\n  color: #fff;\n  padding: 25px 30px;\n  margin: 40px 0;\n}\n.integration p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n.integration strong {\n  color: #fff;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.cta {\n  text-align: center;\n  margin-top: 50px;\n  padding-top: 40px;\n  border-top: 3px solid #000;\n}\n.btn {\n  display: inline-block;\n  padding: 16px 45px;\n  background: #000;\n  color: #fff;\n  text-decoration: none;\n  font-size: 14px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin: 0 10px 15px 0;\n  transition: all 0.3s ease;\n  border: 2px solid #000;\n  border-left: 4px solid #000;\n}\n.btn:hover {\n  background: #333;\n  border-color: #333;\n}\n.btn-outline {\n  background: transparent;\n  color: #000;\n}\n.btn-outline:hover {\n  background: #000;\n  color: #fff;\n}\n\n@media (max-width: 768px) {\n  h1 { font-size: 28px; }\n  .section-title { font-size: 18px; }\n  .btn { display: block; margin: 10px 0; }\n  .compat-grid { grid-template-columns: 1fr; }\n  .specs-table td:first-child { width: 50%; }\n}\n\u003c\/style\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48738677227739,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/10_1.png?v=1777794738","url":"https:\/\/nwspec.com\/ar\/products\/s10-tga-gc-ms-multi-loop-sampler","provider":"NWSPEC","version":"1.0","type":"link"}