{"title":"GC Accessories","description":"","products":[{"product_id":"p6-portable-gc-with-mems-tcd-copy","title":"S6 Automatic Tedlar Bag Sampler","description":"\u003c!-- S6 Automatic Tedlar Bag Sampler - GC SAMPLE INTRODUCTION ACCESSORY --\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"breadcrumb\"\u003e\n\u003cspan\u003eGC Systems\u003c\/span\u003e \u0026gt; \u003cspan\u003eSample Introduction\u003c\/span\u003e \u0026gt; \u003cstrong\u003eS6 Accessory\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003ch1\u003eS6 Automatic Tedlar Bag Sampler\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eAutomated Gas Bag Injection System | NWSPEC GC Accessory Series\u003c\/p\u003e\n\u003cdiv class=\"badge\"\u003eSAMPLE INTRODUCTION\u003c\/div\u003e\n\u003cdiv class=\"highlights\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eS6\u003c\/strong\u003e is an automated sample introduction accessory for NWSPEC Mx series GC systems. It enables fully automatic batch injection of gas bag samples, eliminating manual handling and ensuring high repeatability for ambient air, emissions, and petrochemical gas analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eGC Applications\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003eAmbient air quality monitoring\u003c\/li\u003e\n\u003cli\u003eCooling tower emissions testing\u003c\/li\u003e\n\u003cli\u003eTobacco smoke analysis\u003c\/li\u003e\n\u003cli\u003eSoil water vapor sampling\u003c\/li\u003e\n\u003cli\u003ePetrochemical gas batch analysis\u003c\/li\u003e\n\u003cli\u003eIndustrial hygiene surveys\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eAccessory Features\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully automated operation:\u003c\/strong\u003e Batch and automatic injection of gas bag samples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible configuration:\u003c\/strong\u003e 12\/18\/24\/36 injection positions selectable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVacuum pump equipped:\u003c\/strong\u003e With optional pressure monitoring for automatic purge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtmospheric balancing valve:\u003c\/strong\u003e Ensures ultra-high injection repeatability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniLite plugin embedded:\u003c\/strong\u003e Seamless connection to M6\/M3 GC control systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull GC integration:\u003c\/strong\u003e No PC software installation required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation history tracking:\u003c\/strong\u003e Built-in for full process traceability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInert coating:\u003c\/strong\u003e All internal sample tubing inert-treated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrowser interface:\u003c\/strong\u003e Parameter editing and download via web\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMass flow meter:\u003c\/strong\u003e Real-time sample loop vent flow inspection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard I\/O interface:\u003c\/strong\u003e Synchronization with major GC brands\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eAccessory Specifications\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity (Operating):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Ports:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\/12\/18\/24\/36 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouchscreen:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\" integrated display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBag Interface:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-stage pagoda or ferrule (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Line Heating:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable upon customization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTubing:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\" inert coating stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Interfaces:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485, RS232, TCP\/IP, EVENT, BCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 × 400 × 260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eCompatible GC Systems\u003c\/h2\u003e\n\u003cdiv class=\"compat-grid\"\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC60\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eLab GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC30\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompact GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC20\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEntry GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eThird-party GC\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eVia standard I\/O\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"integration\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e The S6 connects directly to Mx series GC inlets via heated transfer line. All method sequences are edited within the GC's UniLite software interface—no separate PC software needed. Full audit trail maintained.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta\"\u003e\n\u003cspan style=\"color: rgb(255, 255, 255);\"\u003e\u003ca class=\"btn\" href=\"\/en-cn\/pages\/contact\" style=\"color: rgb(255, 255, 255);\"\u003eRequest Accessory Quote\u003c\/a\u003e\u003c\/span\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-container {\n  max-width: 900px;\n  margin: 0 auto;\n  padding: 40px 20px;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n  font-size: 14px;\n  line-height: 1.6;\n  color: #222;\n  background: #fff;\n}\n\n.breadcrumb {\n  font-size: 13px;\n  color: #666;\n  margin-bottom: 20px;\n  padding: 10px 0;\n  border-bottom: 1px solid #eee;\n}\n.breadcrumb span { color: #999; }\n.breadcrumb strong { color: #000; }\n\nh1 {\n  font-size: 36px;\n  font-weight: 700;\n  color: #000;\n  margin: 0 0 10px 0;\n  letter-spacing: -1px;\n}\n\n.subtitle {\n  font-size: 16px;\n  color: #555;\n  margin: 0 0 15px 0;\n  font-weight: 400;\n}\n\n.badge {\n  display: inline-block;\n  background: #000;\n  color: #fff;\n  padding: 6px 20px;\n  font-size: 12px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin-bottom: 30px;\n}\n\n.highlights {\n  background: #f5f5f5;\n  padding: 25px 30px;\n  margin: 30px 0;\n  border-left: 4px solid #000;\n  font-size: 15px;\n  line-height: 1.7;\n}\n.highlights p { margin: 0; }\n\n.section-title {\n  font-size: 22px;\n  font-weight: 700;\n  color: #000;\n  margin: 50px 0 25px 0;\n  padding-bottom: 12px;\n  border-bottom: 3px solid #000;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.feature-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.feature-list li {\n  padding: 12px 0 12px 25px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n  line-height: 1.6;\n  position: relative;\n}\n.feature-list li::before {\n  content: \"—\";\n  position: absolute;\n  left: 0;\n  color: #000;\n  font-weight: bold;\n}\n\n.specs-table {\n  width: 100%;\n  border-collapse: collapse;\n  margin-top: 20px;\n}\n.specs-table td {\n  padding: 12px 15px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n}\n.specs-table td:first-child {\n  width: 40%;\n  color: #000;\n  font-weight: 600;\n}\n\n.compat-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 20px;\n  margin-top: 20px;\n}\n.compat-item {\n  background: #fff;\n  padding: 20px;\n  border: 2px solid #000;\n  text-align: center;\n}\n.compat-item strong {\n  font-size: 16px;\n  display: block;\n  margin-bottom: 5px;\n}\n.compat-item span {\n  font-size: 13px;\n  color: #555;\n}\n\n.integration {\n  background: #000;\n  color: #fff;\n  padding: 25px 30px;\n  margin: 40px 0;\n}\n.integration p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n.integration strong {\n  color: #fff;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.cta {\n  text-align: center;\n  margin-top: 50px;\n  padding-top: 40px;\n  border-top: 3px solid #000;\n}\n.btn {\n  display: inline-block;\n  padding: 16px 45px;\n  background: #000;\n  color: #fff;\n  text-decoration: none;\n  font-size: 14px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin: 0 10px 15px 0;\n  transition: all 0.3s ease;\n  border: 2px solid #000;\n  border-left: 4px solid #000;\n}\n.btn:hover {\n  background: #333;\n  border-color: #333;\n}\n.btn-outline {\n  background: transparent;\n  color: #000;\n}\n.btn-outline:hover {\n  background: #000;\n  color: #fff;\n}\n\n@media (max-width: 768px) {\n  h1 { font-size: 28px; }\n  .section-title { font-size: 18px; }\n  .btn { display: block; margin: 10px 0; }\n  .compat-grid { grid-template-columns: 1fr; }\n  .specs-table td:first-child { width: 50%; }\n}\n\u003c\/style\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48738636464347,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/ad1a1b7183951dc89f508a6b6c422144_f1b2d05d-7677-487d-827d-c1c62ed1d1d4.png?v=1777804015"},{"product_id":"s10-tga-gc-ms-multi-loop-sampler","title":"S10 TGA-GC\/MS Multi-Loop Sampler","description":"\u003c!-- S10 TGA-GC\/MS Auto-Sampler - GC SAMPLE INTRODUCTION ACCESSORY --\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"breadcrumb\"\u003e\n\u003cspan\u003eGC Systems\u003c\/span\u003e \u0026gt; \u003cspan\u003eSample Introduction\u003c\/span\u003e \u0026gt; \u003cstrong\u003eS10 Auto-Sampler\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003ch1\u003eS10 TGA-GC\/MS Auto-Sampler\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eAutomated Sample Introduction from Thermogravimetry to GC-MS | NWSPEC GC Accessory Series\u003c\/p\u003e\n\u003cdiv class=\"badge\"\u003eAUTO-SAMPLER\u003c\/div\u003e\n\u003cdiv class=\"highlights\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eS10\u003c\/strong\u003e is an automated sample introduction accessory that captures time-resolved gas evolved from thermogravimetric analyzers (TGA) and feeds stored samples sequentially into GC-MS for analysis. It solves the fundamental timing mismatch between rapid TGA weight-loss events and slower GC-MS analysis cycles.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"problem-box\"\u003e\n\u003ch3\u003eProblem Solved by S10\u003c\/h3\u003e\n\u003cp\u003eIn traditional TGA-GC-MS setups, users can only inject one sample per TGA run. By the time GC-MS analysis completes, the TGA thermal event is already over—preventing multiple sampling. The S10 auto-sampler captures up to 16 time-resolved samples automatically and introduces them sequentially into the GC-MS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eGC-MS Applications\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003eRubber and polymer thermal degradation analysis\u003c\/li\u003e\n\u003cli\u003eCO2 emission profiling during material heating\u003c\/li\u003e\n\u003cli\u003eVolatile organic compound evolution tracking\u003c\/li\u003e\n\u003cli\u003ePharmaceutical thermal stability studies\u003c\/li\u003e\n\u003cli\u003eCoal and biomass pyrolysis gas analysis\u003c\/li\u003e\n\u003cli\u003eFTIR medium gas bypass analysis supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eAuto-Sampler Features\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-sample capacity:\u003c\/strong\u003e Up to 16 quantitative sample loops for batch analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic trapping:\u003c\/strong\u003e Sample gas captured in loops per programmed schedule\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSequential injection:\u003c\/strong\u003e Stored samples introduced into GC-MS one by one\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware-configurable timing:\u003c\/strong\u003e Sampling intervals set per TGA heating program\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated gas sampling valve:\u003c\/strong\u003e Built-in GSV—no GC-end configuration needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-play inlet:\u003c\/strong\u003e 1\/32\" inert tube inserts into standard GC S\/SL port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero GC modification:\u003c\/strong\u003e No changes required to injection port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal mounting bracket:\u003c\/strong\u003e Compatible with mainstream GC-MS systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeated valve box:\u003c\/strong\u003e All valves and loops heated up to 300°C (max 330°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInert treatment:\u003c\/strong\u003e All sample tubes treated to prevent adsorption\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConcentration curves:\u003c\/strong\u003e Component trend export via chromatograph software\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBypass to FTIR:\u003c\/strong\u003e Parallel connection to infrared analyzer supported\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eAuto-Sampler Specifications\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Valve Box Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Loops:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\/10\/12\/16 (standard: 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Valves:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (sampling, injection, isolation - Vici)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Volume:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250μL (optional 500μL, 1mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Line Max Temp:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Line:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInert treated stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220Vac, 5 amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarrier Gas:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir @ 4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeakage Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 × 10⁻⁸ atm-cc\/sec He\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470H × 230W × 430L mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect via browser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMethod Setting:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGC interface or PC software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\" Swagelok\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP, RS485, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouchscreen:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\" integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eCompatible GC-MS Systems\u003c\/h2\u003e\n\u003cdiv class=\"compat-grid\"\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eAgilent\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eGC-MSD Series\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eThermo Fisher\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eISQ \/ TSQ Series\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eShimadzu\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eGCMS-QP Series\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eNWSPEC GC60\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWith MS Module\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"integration\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e The S10 auto-sampler acts as a time-resolved sampling bridge between TGA and GC-MS. Users program sampling intervals matching their TGA heating ramp. The S10 automatically stores evolved gases and feeds them sequentially to the GC-MS—enabling complete thermal profile analysis that was previously impossible with single-injection setups.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta\"\u003e\n\u003cspan style=\"color: rgb(255, 255, 255);\"\u003e\u003ca class=\"btn\" href=\"\/en-cn\/pages\/contact\" style=\"color: rgb(255, 255, 255);\"\u003eRequest Auto-Sampler Quote\u003c\/a\u003e\u003c\/span\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-container {\n  max-width: 900px;\n  margin: 0 auto;\n  padding: 40px 20px;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n  font-size: 14px;\n  line-height: 1.6;\n  color: #222;\n  background: #fff;\n}\n\n.breadcrumb {\n  font-size: 13px;\n  color: #666;\n  margin-bottom: 20px;\n  padding: 10px 0;\n  border-bottom: 1px solid #eee;\n}\n.breadcrumb span { color: #999; }\n.breadcrumb strong { color: #000; }\n\nh1 {\n  font-size: 36px;\n  font-weight: 700;\n  color: #000;\n  margin: 0 0 10px 0;\n  letter-spacing: -1px;\n}\n\n.subtitle {\n  font-size: 16px;\n  color: #555;\n  margin: 0 0 15px 0;\n  font-weight: 400;\n}\n\n.badge {\n  display: inline-block;\n  background: #000;\n  color: #fff;\n  padding: 6px 20px;\n  font-size: 12px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin-bottom: 30px;\n}\n\n.highlights {\n  background: #f5f5f5;\n  padding: 25px 30px;\n  margin: 30px 0;\n  border-left: 4px solid #000;\n  font-size: 15px;\n  line-height: 1.7;\n}\n.highlights p { margin: 0; }\n\n.problem-box {\n  background: #fff;\n  padding: 25px 30px;\n  margin: 20px 0;\n  border: 2px solid #000;\n}\n.problem-box h3 {\n  margin: 0 0 15px 0;\n  font-size: 16px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n.problem-box p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n\n.section-title {\n  font-size: 22px;\n  font-weight: 700;\n  color: #000;\n  margin: 50px 0 25px 0;\n  padding-bottom: 12px;\n  border-bottom: 3px solid #000;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.feature-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.feature-list li {\n  padding: 12px 0 12px 25px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n  line-height: 1.6;\n  position: relative;\n}\n.feature-list li::before {\n  content: \"—\";\n  position: absolute;\n  left: 0;\n  color: #000;\n  font-weight: bold;\n}\n\n.specs-table {\n  width: 100%;\n  border-collapse: collapse;\n  margin-top: 20px;\n}\n.specs-table td {\n  padding: 12px 15px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n}\n.specs-table td:first-child {\n  width: 45%;\n  color: #000;\n  font-weight: 600;\n}\n\n.compat-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 20px;\n  margin-top: 20px;\n}\n.compat-item {\n  background: #fff;\n  padding: 20px;\n  border: 2px solid #000;\n  text-align: center;\n}\n.compat-item strong {\n  font-size: 16px;\n  display: block;\n  margin-bottom: 5px;\n}\n.compat-item span {\n  font-size: 13px;\n  color: #555;\n}\n\n.integration {\n  background: #000;\n  color: #fff;\n  padding: 25px 30px;\n  margin: 40px 0;\n}\n.integration p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n.integration strong {\n  color: #fff;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.cta {\n  text-align: center;\n  margin-top: 50px;\n  padding-top: 40px;\n  border-top: 3px solid #000;\n}\n.btn {\n  display: inline-block;\n  padding: 16px 45px;\n  background: #000;\n  color: #fff;\n  text-decoration: none;\n  font-size: 14px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin: 0 10px 15px 0;\n  transition: all 0.3s ease;\n  border: 2px solid #000;\n  border-left: 4px solid #000;\n}\n.btn:hover {\n  background: #333;\n  border-color: #333;\n}\n.btn-outline {\n  background: transparent;\n  color: #000;\n}\n.btn-outline:hover {\n  background: #000;\n  color: #fff;\n}\n\n@media (max-width: 768px) {\n  h1 { font-size: 28px; }\n  .section-title { font-size: 18px; }\n  .btn { display: block; margin: 10px 0; }\n  .compat-grid { grid-template-columns: 1fr; }\n  .specs-table td:first-child { width: 50%; }\n}\n\u003c\/style\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48738677227739,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/10_1.png?v=1777794738"},{"product_id":"s61-automatic-sample-vaporizer","title":"S61 Automatic Sample Vaporizer","description":"\u003c!-- S61 Automatic Sample Vaporizer - GC SAMPLE INTRODUCTION ACCESSORY --\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"breadcrumb\"\u003e\n\u003cspan\u003eGC Systems\u003c\/span\u003e \u0026gt; \u003cspan\u003eSample Introduction\u003c\/span\u003e \u0026gt; \u003cstrong\u003eS61 Vaporizer\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003ch1\u003eS61 Automatic Sample Vaporizer\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eHigh-Pressure Liquid-to-Gas Sample Vaporization for GC | NWSPEC GC Accessory Series\u003c\/p\u003e\n\u003cdiv class=\"badge\"\u003eSAMPLE VAPORIZER\u003c\/div\u003e\n\u003cdiv class=\"highlights\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eS61\u003c\/strong\u003e is an automatic sample vaporizer that transforms high-pressure liquid samples (LPG, LNG, ethylene, propylene) into stable gas samples for GC inlet injection. It eliminates discrimination and repeatability issues common in manual sample introduction through precision heating and pressure control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eGC Applications\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003eLPG (liquefied petroleum gas) component analysis\u003c\/li\u003e\n\u003cli\u003eLNG (liquefied natural gas) quality control\u003c\/li\u003e\n\u003cli\u003eTrace water in ethylene and propylene\u003c\/li\u003e\n\u003cli\u003eTrace water in butadiene\u003c\/li\u003e\n\u003cli\u003eDimethyl ether content in LPG\u003c\/li\u003e\n\u003cli\u003eTrace sulfur in polymerization-grade olefins\u003c\/li\u003e\n\u003cli\u003eTrace oxygen in olefins\u003c\/li\u003e\n\u003cli\u003eRefrigerant purity analysis\u003c\/li\u003e\n\u003cli\u003eVinyl chloride monomer analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eVaporizer Features\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull gasification:\u003c\/strong\u003e Complete liquid-to-vapor conversion with auto-purging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAtmospheric balance valve:\u003c\/strong\u003e Ensures high repeatability in sample loop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuto-set parameters:\u003c\/strong\u003e Injection time and volume programmable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-temperature capability:\u003c\/strong\u003e Max 350°C with ±0.1°C accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-inch touchscreen:\u003c\/strong\u003e Operation display with full history records\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInert coating:\u003c\/strong\u003e All sample tubing inert-treated for reactive compounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard I\/O:\u003c\/strong\u003e Direct synchronization with mainstream GC brands\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrowser control:\u003c\/strong\u003e Status check, parameter edit, and download via web\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlowmeter integrated:\u003c\/strong\u003e Real-time flow monitoring during vaporization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect GC connection:\u003c\/strong\u003e Plugs into Mx series GC inlets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod integration:\u003c\/strong\u003e Edited within GC software—no separate program needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eAvailable Configurations\u003c\/h2\u003e\n\u003cdiv class=\"variant-grid\"\u003e\n\u003cdiv class=\"variant-item\"\u003e\n\u003cstrong\u003eS61 Standard\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eSingle-channel laboratory vaporizer for Mx series GC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"variant-item\"\u003e\n\u003cstrong\u003eS61-X\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eMulti-channel switching (4-6 cylinders) for automated batch analysis\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"variant-item\"\u003e\n\u003cstrong\u003eS61-R\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePortable vaporizer module for P6 portable GC field applications\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eVaporizer Specifications\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Vaporization Temp:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350°C (±0.1°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouchscreen:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\" integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Cylinder Interface:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\" stainless-steel ferrule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-channel Interface:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless-steel quick-connect (customizable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Pipeline:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-length heat tracing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBalance Valve:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTubing Purging:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Tubing:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\" inert coating stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Interfaces:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485, RS232, TCP\/IP, EVENT, BCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 × 400 × 260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eCompatible GC Systems\u003c\/h2\u003e\n\u003cdiv class=\"compat-grid\"\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC60\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eLab GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC30\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompact GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eP6\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePortable GC (with S61-R)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eThird-party GC\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eVia standard I\/O\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"integration\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e The S61 employs a special heating vaporization valve ensuring consistent outlet pressure for reliable GC inlet injection. All tubing is inert-coated and heated for accurate analysis of reactive olefins and sulfides. The S61-X multi-channel variant enables unattended vaporization of up to 6 cylinders in sequence, while the S61-R portable module brings laboratory-grade sample vaporization accuracy to field applications with the P6.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta\"\u003e\n\u003cspan style=\"color: rgb(255, 255, 255);\"\u003e\u003ca class=\"btn\" href=\"\/en-cn\/pages\/contact\" style=\"color: rgb(255, 255, 255);\"\u003eRequest Vaporizer Quote\u003c\/a\u003e\u003c\/span\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-container {\n  max-width: 900px;\n  margin: 0 auto;\n  padding: 40px 20px;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n  font-size: 14px;\n  line-height: 1.6;\n  color: #222;\n  background: #fff;\n}\n\n.breadcrumb {\n  font-size: 13px;\n  color: #666;\n  margin-bottom: 20px;\n  padding: 10px 0;\n  border-bottom: 1px solid #eee;\n}\n.breadcrumb span { color: #999; }\n.breadcrumb strong { color: #000; }\n\nh1 {\n  font-size: 36px;\n  font-weight: 700;\n  color: #000;\n  margin: 0 0 10px 0;\n  letter-spacing: -1px;\n}\n\n.subtitle {\n  font-size: 16px;\n  color: #555;\n  margin: 0 0 15px 0;\n  font-weight: 400;\n}\n\n.badge {\n  display: inline-block;\n  background: #000;\n  color: #fff;\n  padding: 6px 20px;\n  font-size: 12px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin-bottom: 30px;\n}\n\n.highlights {\n  background: #f5f5f5;\n  padding: 25px 30px;\n  margin: 30px 0;\n  border-left: 4px solid #000;\n  font-size: 15px;\n  line-height: 1.7;\n}\n.highlights p { margin: 0; }\n\n.section-title {\n  font-size: 22px;\n  font-weight: 700;\n  color: #000;\n  margin: 50px 0 25px 0;\n  padding-bottom: 12px;\n  border-bottom: 3px solid #000;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.feature-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.feature-list li {\n  padding: 12px 0 12px 25px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n  line-height: 1.6;\n  position: relative;\n}\n.feature-list li::before {\n  content: \"—\";\n  position: absolute;\n  left: 0;\n  color: #000;\n  font-weight: bold;\n}\n\n.variant-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n  gap: 20px;\n  margin-top: 20px;\n}\n.variant-item {\n  background: #fff;\n  padding: 25px;\n  border: 2px solid #000;\n}\n.variant-item strong {\n  font-size: 16px;\n  display: block;\n  margin-bottom: 8px;\n}\n.variant-item span {\n  font-size: 14px;\n  color: #555;\n  line-height: 1.5;\n}\n\n.specs-table {\n  width: 100%;\n  border-collapse: collapse;\n  margin-top: 20px;\n}\n.specs-table td {\n  padding: 12px 15px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n}\n.specs-table td:first-child {\n  width: 45%;\n  color: #000;\n  font-weight: 600;\n}\n\n.compat-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 20px;\n  margin-top: 20px;\n}\n.compat-item {\n  background: #fff;\n  padding: 20px;\n  border: 2px solid #000;\n  text-align: center;\n}\n.compat-item strong {\n  font-size: 16px;\n  display: block;\n  margin-bottom: 5px;\n}\n.compat-item span {\n  font-size: 13px;\n  color: #555;\n}\n\n.integration {\n  background: #000;\n  color: #fff;\n  padding: 25px 30px;\n  margin: 40px 0;\n}\n.integration p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n.integration strong {\n  color: #fff;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.cta {\n  text-align: center;\n  margin-top: 50px;\n  padding-top: 40px;\n  border-top: 3px solid #000;\n}\n.btn {\n  display: inline-block;\n  padding: 16px 45px;\n  background: #000;\n  color: #fff;\n  text-decoration: none;\n  font-size: 14px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin: 0 10px 15px 0;\n  transition: all 0.3s ease;\n  border: 2px solid #000;\n  border-left: 4px solid #000;\n}\n.btn:hover {\n  background: #333;\n  border-color: #333;\n}\n.btn-outline {\n  background: transparent;\n  color: #000;\n}\n.btn-outline:hover {\n  background: #000;\n  color: #fff;\n}\n\n@media (max-width: 768px) {\n  h1 { font-size: 28px; }\n  .section-title { font-size: 18px; }\n  .btn { display: block; margin: 10px 0; }\n  .compat-grid { grid-template-columns: 1fr; }\n  .variant-grid { grid-template-columns: 1fr; }\n  .specs-table td:first-child { width: 50%; }\n}\n\u003c\/style\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48738727624923,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/S61_314bb67a-28a2-4a69-a745-30e3c54130a8.png?v=1777796439"},{"product_id":"t2-intelligent-thermodesorber","title":"T2 Intelligent Thermodesorber","description":"\u003c!-- D2 Dynamic Calibrator - GC CALIBRATION ACCESSORY --\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"breadcrumb\"\u003e\n\u003cspan\u003eGC Systems\u003c\/span\u003e \u0026gt; \u003cspan\u003eCalibration\u003c\/span\u003e \u0026gt; \u003cstrong\u003eD2 Accessory\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003ch1\u003eD2 Dynamic Calibrator\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eAutomated Gas Standard Preparation System | NWSPEC GC Accessory Series\u003c\/p\u003e\n\u003cdiv class=\"badge\"\u003eCALIBRATION\u003c\/div\u003e\n\u003cdiv class=\"highlights\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eD2\u003c\/strong\u003e is a calibration accessory that prepares precise gas standard samples for GC system validation. It supports both mass flow controller (MFC) and differential pressure dilution methods, achieving ratios up to 20,000:1 for trace-level calibration—eliminating manual gas mixing errors and standard gas waste.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eGC Calibration Applications\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003eGC system daily calibration and validation\u003c\/li\u003e\n\u003cli\u003eMulti-compound mixed gas standard preparation\u003c\/li\u003e\n\u003cli\u003eTrace-level compound calibration (ppb range)\u003c\/li\u003e\n\u003cli\u003eCorrosive gas sample dilution (inert path option)\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring standard generation\u003c\/li\u003e\n\u003cli\u003eProcess GC continuous calibration support\u003c\/li\u003e\n\u003cli\u003eSecondary dilution for ultra-trace standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eCalibration Features\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual dilution modes:\u003c\/strong\u003e MFC calculation and differential pressure methods\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtreme dilution ratio:\u003c\/strong\u003e Up to 20,000:1 (differential pressure mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-MFC configuration:\u003c\/strong\u003e Up to 5 MFCs for complex mixing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-cylinder input:\u003c\/strong\u003e Dilute up to 4 standard gas bottles simultaneously\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36 pre-set ratios:\u003c\/strong\u003e Quick selection for common calibration points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in buffer tank:\u003c\/strong\u003e 1200ml coated tank for differential pressure mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero gas waste:\u003c\/strong\u003e Auto-fills only required amount—no venting loss\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated vacuum pump:\u003c\/strong\u003e With optional pressure monitoring for purging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary dilution:\u003c\/strong\u003e Advanced algorithm for multi-stage dilution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInert path option:\u003c\/strong\u003e Fully inert-treated for corrosive samples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniLite plugin:\u003c\/strong\u003e Connects to M6\/M3 GC software directly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-inch touchscreen:\u003c\/strong\u003e Full programming and status display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrowser control:\u003c\/strong\u003e Parameter edit and download via web\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard I\/O:\u003c\/strong\u003e EVENT and BCD ports for GC synchronization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eDilution Modes\u003c\/h2\u003e\n\u003cdiv class=\"mode-grid\"\u003e\n\u003cdiv class=\"mode-item\"\u003e\n\u003ch3\u003eMFC Dilution Mode\u003c\/h3\u003e\n\u003cul class=\"mode-list\"\u003e\n\u003cli\u003eMax ratio: 2,500:1\u003c\/li\u003e\n\u003cli\u003eMFC count: Up to 5\u003c\/li\u003e\n\u003cli\u003eBest for: Multi-gas mixing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mode-item\"\u003e\n\u003ch3\u003eDifferential Pressure Mode\u003c\/h3\u003e\n\u003cul class=\"mode-list\"\u003e\n\u003cli\u003eMax ratio: 20,000:1\u003c\/li\u003e\n\u003cli\u003eTank volume: 1,200ml (coated)\u003c\/li\u003e\n\u003cli\u003eBest for: Ultra-trace standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eCalibration Specifications\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouchscreen:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\" integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\" ferrule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Line Heating:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 330°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBalance Valve:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTubing Purging:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Line:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\" inert coating stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Interfaces:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485, EVENT, BCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 × 400 × 260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMFC Max Dilution:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,500:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Max Dilution:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eCompatible GC Systems\u003c\/h2\u003e\n\u003cdiv class=\"compat-grid\"\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC60\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eLab GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC30\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompact GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eP5\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eRack GC (continuous monitoring)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eThird-party GC\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eVia EVENT\/BCD\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"integration\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e The D2 connects directly to GC calibration gas inlets via EVENT\/BCD synchronization. When paired with the P5 rack GC for continuous monitoring, it enables fully automated 7×24 calibration cycles. The differential pressure mode's 1,200ml coated buffer tank eliminates standard gas waste by filling only the precise amount needed for each calibration point.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta\"\u003e\n\u003cspan style=\"color: rgb(255, 255, 255);\"\u003e\u003ca class=\"btn\" href=\"\/en-cn\/pages\/contact\" style=\"color: rgb(255, 255, 255);\"\u003eRequest Calibrator Quote\u003c\/a\u003e\u003c\/span\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-container {\n  max-width: 900px;\n  margin: 0 auto;\n  padding: 40px 20px;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n  font-size: 14px;\n  line-height: 1.6;\n  color: #222;\n  background: #fff;\n}\n\n.breadcrumb {\n  font-size: 13px;\n  color: #666;\n  margin-bottom: 20px;\n  padding: 10px 0;\n  border-bottom: 1px solid #eee;\n}\n.breadcrumb span { color: #999; }\n.breadcrumb strong { color: #000; }\n\nh1 {\n  font-size: 36px;\n  font-weight: 700;\n  color: #000;\n  margin: 0 0 10px 0;\n  letter-spacing: -1px;\n}\n\n.subtitle {\n  font-size: 16px;\n  color: #555;\n  margin: 0 0 15px 0;\n  font-weight: 400;\n}\n\n.badge {\n  display: inline-block;\n  background: #000;\n  color: #fff;\n  padding: 6px 20px;\n  font-size: 12px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin-bottom: 30px;\n}\n\n.highlights {\n  background: #f5f5f5;\n  padding: 25px 30px;\n  margin: 30px 0;\n  border-left: 4px solid #000;\n  font-size: 15px;\n  line-height: 1.7;\n}\n.highlights p { margin: 0; }\n\n.section-title {\n  font-size: 22px;\n  font-weight: 700;\n  color: #000;\n  margin: 50px 0 25px 0;\n  padding-bottom: 12px;\n  border-bottom: 3px solid #000;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.feature-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.feature-list li {\n  padding: 12px 0 12px 25px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n  line-height: 1.6;\n  position: relative;\n}\n.feature-list li::before {\n  content: \"—\";\n  position: absolute;\n  left: 0;\n  color: #000;\n  font-weight: bold;\n}\n\n.mode-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n  gap: 25px;\n  margin-top: 20px;\n}\n.mode-item {\n  background: #fff;\n  padding: 25px;\n  border: 2px solid #000;\n}\n.mode-item h3 {\n  margin: 0 0 15px 0;\n  font-size: 16px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n.mode-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.mode-list li {\n  padding: 8px 0;\n  font-size: 14px;\n  border-bottom: 1px solid #eee;\n}\n\n.specs-table {\n  width: 100%;\n  border-collapse: collapse;\n  margin-top: 20px;\n}\n.specs-table td {\n  padding: 12px 15px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n}\n.specs-table td:first-child {\n  width: 45%;\n  color: #000;\n  font-weight: 600;\n}\n\n.compat-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 20px;\n  margin-top: 20px;\n}\n.compat-item {\n  background: #fff;\n  padding: 20px;\n  border: 2px solid #000;\n  text-align: center;\n}\n.compat-item strong {\n  font-size: 16px;\n  display: block;\n  margin-bottom: 5px;\n}\n.compat-item span {\n  font-size: 13px;\n  color: #555;\n}\n\n.integration {\n  background: #000;\n  color: #fff;\n  padding: 25px 30px;\n  margin: 40px 0;\n}\n.integration p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n.integration strong {\n  color: #fff;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.cta {\n  text-align: center;\n  margin-top: 50px;\n  padding-top: 40px;\n  border-top: 3px solid #000;\n}\n.btn {\n  display: inline-block;\n  padding: 16px 45px;\n  background: #000;\n  color: #fff;\n  text-decoration: none;\n  font-size: 14px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin: 0 10px 15px 0;\n  transition: all 0.3s ease;\n  border: 2px solid #000;\n  border-left: 4px solid #000;\n}\n.btn:hover {\n  background: #333;\n  border-color: #333;\n}\n.btn-outline {\n  background: transparent;\n  color: #000;\n}\n.btn-outline:hover {\n  background: #000;\n  color: #fff;\n}\n\n@media (max-width: 768px) {\n  h1 { font-size: 28px; }\n  .section-title { font-size: 18px; }\n  .btn { display: block; margin: 10px 0; }\n  .compat-grid { grid-template-columns: 1fr; }\n  .mode-grid { grid-template-columns: 1fr; }\n  .specs-table td:first-child { width: 50%; }\n}\n\u003c\/style\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48738803679451,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/T2.png?v=1777803872"},{"product_id":"t2-intelligent-thermodesorber-copy","title":"D2 Dynamic Calibrator","description":"\u003cp\u003e\u003cspan style=\"font-size: 13px; background-color: rgb(255, 255, 255); font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif;\"\u003eGC Systems\u003c\/span\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-size: 13px; background-color: rgb(255, 255, 255); font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif;\"\u003e \u0026gt; \u003c\/span\u003e\u003cspan style=\"font-size: 13px; background-color: rgb(255, 255, 255); font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif;\"\u003eCalibration\u003c\/span\u003e\u003cspan style=\"color: rgb(102, 102, 102); font-size: 13px; background-color: rgb(255, 255, 255); font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif;\"\u003e \u0026gt; \u003c\/span\u003e\u003cstrong style=\"font-size: 13px; background-color: rgb(255, 255, 255); font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif;\"\u003eD2 Accessory\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003ch1\u003eD2 Dynamic Calibrator\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eAutomated Gas Standard Preparation System | NWSPEC GC Accessory Series\u003c\/p\u003e\n\u003cdiv class=\"badge\"\u003eCALIBRATION\u003c\/div\u003e\n\u003cdiv class=\"highlights\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eD2\u003c\/strong\u003e is a calibration accessory that prepares precise gas standard samples for GC system validation. It supports both mass flow controller (MFC) and differential pressure dilution methods, achieving ratios up to 20,000:1 for trace-level calibration—eliminating manual gas mixing errors and standard gas waste.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eGC Calibration Applications\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003eGC system daily calibration and validation\u003c\/li\u003e\n\u003cli\u003eMulti-compound mixed gas standard preparation\u003c\/li\u003e\n\u003cli\u003eTrace-level compound calibration (ppb range)\u003c\/li\u003e\n\u003cli\u003eCorrosive gas sample dilution (inert path option)\u003c\/li\u003e\n\u003cli\u003eEnvironmental monitoring standard generation\u003c\/li\u003e\n\u003cli\u003eProcess GC continuous calibration support\u003c\/li\u003e\n\u003cli\u003eSecondary dilution for ultra-trace standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eCalibration Features\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual dilution modes:\u003c\/strong\u003e MFC calculation and differential pressure methods\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtreme dilution ratio:\u003c\/strong\u003e Up to 20,000:1 (differential pressure mode)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-MFC configuration:\u003c\/strong\u003e Up to 5 MFCs for complex mixing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-cylinder input:\u003c\/strong\u003e Dilute up to 4 standard gas bottles simultaneously\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36 pre-set ratios:\u003c\/strong\u003e Quick selection for common calibration points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in buffer tank:\u003c\/strong\u003e 1200ml coated tank for differential pressure mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZero gas waste:\u003c\/strong\u003e Auto-fills only required amount—no venting loss\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomated vacuum pump:\u003c\/strong\u003e With optional pressure monitoring for purging\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary dilution:\u003c\/strong\u003e Advanced algorithm for multi-stage dilution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInert path option:\u003c\/strong\u003e Fully inert-treated for corrosive samples\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniLite plugin:\u003c\/strong\u003e Connects to M6\/M3 GC software directly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-inch touchscreen:\u003c\/strong\u003e Full programming and status display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrowser control:\u003c\/strong\u003e Parameter edit and download via web\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard I\/O:\u003c\/strong\u003e EVENT and BCD ports for GC synchronization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eDilution Modes\u003c\/h2\u003e\n\u003cdiv class=\"mode-grid\"\u003e\n\u003cdiv class=\"mode-item\"\u003e\n\u003ch3\u003eMFC Dilution Mode\u003c\/h3\u003e\n\u003cul class=\"mode-list\"\u003e\n\u003cli\u003eMax ratio: 2,500:1\u003c\/li\u003e\n\u003cli\u003eMFC count: Up to 5\u003c\/li\u003e\n\u003cli\u003eBest for: Multi-gas mixing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mode-item\"\u003e\n\u003ch3\u003eDifferential Pressure Mode\u003c\/h3\u003e\n\u003cul class=\"mode-list\"\u003e\n\u003cli\u003eMax ratio: 20,000:1\u003c\/li\u003e\n\u003cli\u003eTank volume: 1,200ml (coated)\u003c\/li\u003e\n\u003cli\u003eBest for: Ultra-trace standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eCalibration Specifications\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouchscreen:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\" integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\" ferrule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Line Heating:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 330°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBalance Valve:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTubing Purging:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Line:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/16\" inert coating stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Interfaces:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485, EVENT, BCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220V, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350 × 400 × 260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMFC Max Dilution:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,500:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Max Dilution:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eCompatible GC Systems\u003c\/h2\u003e\n\u003cdiv class=\"compat-grid\"\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC60\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eLab GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC30\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompact GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eP5\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eRack GC (continuous monitoring)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eThird-party GC\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eVia EVENT\/BCD\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"integration\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e The D2 connects directly to GC calibration gas inlets via EVENT\/BCD synchronization. When paired with the P5 rack GC for continuous monitoring, it enables fully automated 7×24 calibration cycles. The differential pressure mode's 1,200ml coated buffer tank eliminates standard gas waste by filling only the precise amount needed for each calibration point.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta\"\u003e\n\u003cspan style=\"color: rgb(255, 255, 255);\"\u003e\u003ca style=\"color: rgb(255, 255, 255);\" href=\"\/en-cn\/pages\/contact\" class=\"btn\"\u003eRequest Calibrator Quote\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-container {\n  max-width: 900px;\n  margin: 0 auto;\n  padding: 40px 20px;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n  font-size: 14px;\n  line-height: 1.6;\n  color: #222;\n  background: #fff;\n}\n\n.breadcrumb {\n  font-size: 13px;\n  color: #666;\n  margin-bottom: 20px;\n  padding: 10px 0;\n  border-bottom: 1px solid #eee;\n}\n.breadcrumb span { color: #999; }\n.breadcrumb strong { color: #000; }\n\nh1 {\n  font-size: 36px;\n  font-weight: 700;\n  color: #000;\n  margin: 0 0 10px 0;\n  letter-spacing: -1px;\n}\n\n.subtitle {\n  font-size: 16px;\n  color: #555;\n  margin: 0 0 15px 0;\n  font-weight: 400;\n}\n\n.badge {\n  display: inline-block;\n  background: #000;\n  color: #fff;\n  padding: 6px 20px;\n  font-size: 12px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin-bottom: 30px;\n}\n\n.highlights {\n  background: #f5f5f5;\n  padding: 25px 30px;\n  margin: 30px 0;\n  border-left: 4px solid #000;\n  font-size: 15px;\n  line-height: 1.7;\n}\n.highlights p { margin: 0; }\n\n.section-title {\n  font-size: 22px;\n  font-weight: 700;\n  color: #000;\n  margin: 50px 0 25px 0;\n  padding-bottom: 12px;\n  border-bottom: 3px solid #000;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.feature-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.feature-list li {\n  padding: 12px 0 12px 25px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n  line-height: 1.6;\n  position: relative;\n}\n.feature-list li::before {\n  content: \"—\";\n  position: absolute;\n  left: 0;\n  color: #000;\n  font-weight: bold;\n}\n\n.mode-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n  gap: 25px;\n  margin-top: 20px;\n}\n.mode-item {\n  background: #fff;\n  padding: 25px;\n  border: 2px solid #000;\n}\n.mode-item h3 {\n  margin: 0 0 15px 0;\n  font-size: 16px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n.mode-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.mode-list li {\n  padding: 8px 0;\n  font-size: 14px;\n  border-bottom: 1px solid #eee;\n}\n\n.specs-table {\n  width: 100%;\n  border-collapse: collapse;\n  margin-top: 20px;\n}\n.specs-table td {\n  padding: 12px 15px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n}\n.specs-table td:first-child {\n  width: 45%;\n  color: #000;\n  font-weight: 600;\n}\n\n.compat-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 20px;\n  margin-top: 20px;\n}\n.compat-item {\n  background: #fff;\n  padding: 20px;\n  border: 2px solid #000;\n  text-align: center;\n}\n.compat-item strong {\n  font-size: 16px;\n  display: block;\n  margin-bottom: 5px;\n}\n.compat-item span {\n  font-size: 13px;\n  color: #555;\n}\n\n.integration {\n  background: #000;\n  color: #fff;\n  padding: 25px 30px;\n  margin: 40px 0;\n}\n.integration p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n.integration strong {\n  color: #fff;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.cta {\n  text-align: center;\n  margin-top: 50px;\n  padding-top: 40px;\n  border-top: 3px solid #000;\n}\n.btn {\n  display: inline-block;\n  padding: 16px 45px;\n  background: #000;\n  color: #fff;\n  text-decoration: none;\n  font-size: 14px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin: 0 10px 15px 0;\n  transition: all 0.3s ease;\n  border: 2px solid #000;\n  border-left: 4px solid #000;\n}\n.btn:hover {\n  background: #333;\n  border-color: #333;\n}\n.btn-outline {\n  background: transparent;\n  color: #000;\n}\n.btn-outline:hover {\n  background: #000;\n  color: #fff;\n}\n\n@media (max-width: 768px) {\n  h1 { font-size: 28px; }\n  .section-title { font-size: 18px; }\n  .btn { display: block; margin: 10px 0; }\n  .compat-grid { grid-template-columns: 1fr; }\n  .mode-grid { grid-template-columns: 1fr; }\n  .specs-table td:first-child { width: 50%; }\n}\n\u003c\/style\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48738808889563,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/D2_066684c1-febd-460d-b978-be83a1cc4f79.png?v=1777797973"},{"product_id":"h6-intelligent-headspace","title":"H6 Intelligent Headspace","description":"\u003c!-- H6 Intelligent Headspace - GC SAMPLE PRETREATMENT ACCESSORY --\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"breadcrumb\"\u003e\n\u003cspan\u003eGC Systems\u003c\/span\u003e \u0026gt; \u003cspan\u003eSample Pretreatment\u003c\/span\u003e \u0026gt; \u003cstrong\u003eH6 Accessory\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003ch1\u003eH6 Intelligent Headspace\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eAutomated Purge-and-Trap Headspace for GC\/GC-MS | NWSPEC GC Accessory Series\u003c\/p\u003e\n\u003cdiv class=\"badge\"\u003eSAMPLE PRETREATMENT\u003c\/div\u003e\n\u003cdiv class=\"highlights\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eH6\u003c\/strong\u003e is a sample pretreatment accessory that automates purge-and-trap headspace analysis for GC and GC-MS systems. It uses high-precision syringe sampling with helium\/nitrogen purge gas, trapping volatile compounds from liquid or solid matrices for sensitive chromatographic detection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eGC Applications\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003eDrinking water and wastewater organic pollutant analysis\u003c\/li\u003e\n\u003cli\u003eFood and beverage odor component profiling\u003c\/li\u003e\n\u003cli\u003ePharmaceutical residual solvent testing (USP\/EP)\u003c\/li\u003e\n\u003cli\u003eEnvironmental soil and sediment volatiles\u003c\/li\u003e\n\u003cli\u003ePolymer and resin outgassing characterization\u003c\/li\u003e\n\u003cli\u003eCosmetics and fragrance volatile analysis\u003c\/li\u003e\n\u003cli\u003eForensic toxicology sample screening\u003c\/li\u003e\n\u003cli\u003eIndustrial chemical purity verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003ePretreatment Features\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e54 sample positions:\u003c\/strong\u003e High-capacity batch processing with 10 heating positions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample vibration:\u003c\/strong\u003e Standard oven vibration with stepless speed regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverlap injection:\u003c\/strong\u003e Consistent equilibrium time for every sample\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXYZ robotic arm:\u003c\/strong\u003e Stable and reliable vial handling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGC-integrated control:\u003c\/strong\u003e All parameters edited via chromatograph screen\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod storage:\u003c\/strong\u003e 20 headspace method files, directly retrievable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic flow control:\u003c\/strong\u003e High-precision gas path regulation module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal standard addition:\u003c\/strong\u003e 4-position 40ml automatic addition module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrogate spiking:\u003c\/strong\u003e Automatic surrogate addition for QA\/QC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVial status monitoring:\u003c\/strong\u003e Real-time in-place detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeak detection:\u003c\/strong\u003e Pre-test check for each sample position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBubble detector:\u003c\/strong\u003e Standard sensor with automatic defoaming\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess traceability:\u003c\/strong\u003e Actual parameters recorded per sample\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniLite integration:\u003c\/strong\u003e Method seamlessly embedded in GC workflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003ePretreatment Specifications\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Capacity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Positions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, stepless speed regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInjection Method:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverlap for consistent equilibrium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Handling:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXYZ robotic arm with grips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Interface:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChromatograph touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMethod Storage:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 sequence files\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Standard Module:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-position, 40ml high-precision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurrogate Addition:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, high accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVial Monitoring:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReal-time in-place status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeak Detection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePer-sample pre-test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBubble Detection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard with auto defoaming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniLite plugin (GC-integrated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eCompatible GC\/GC-MS Systems\u003c\/h2\u003e\n\u003cdiv class=\"compat-grid\"\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC60\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eLab GC\/GC-MS\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC30\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompact GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC20\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEntry GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eThird-party GC\/GC-MS\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eVia standard I\/O\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"integration\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e The H6 operates as a fully integrated pretreatment module within the Mx series GC\/GC-MS method structure. All headspace parameters—including oven temperature, equilibration time, purge flow, and trap desorption—are edited in the same method file as column and detector settings. The XYZ robotic arm, bubble detector, and leak check work autonomously while the GC runs previous samples, maximizing throughput.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta\"\u003e\n\u003cspan style=\"color: rgb(255, 255, 255);\"\u003e\u003ca class=\"btn\" href=\"\/en-cn\/pages\/contact\" style=\"color: rgb(255, 255, 255);\"\u003eRequest Headspace Quote\u003c\/a\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-container {\n  max-width: 900px;\n  margin: 0 auto;\n  padding: 40px 20px;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n  font-size: 14px;\n  line-height: 1.6;\n  color: #222;\n  background: #fff;\n}\n\n.breadcrumb {\n  font-size: 13px;\n  color: #666;\n  margin-bottom: 20px;\n  padding: 10px 0;\n  border-bottom: 1px solid #eee;\n}\n.breadcrumb span { color: #999; }\n.breadcrumb strong { color: #000; }\n\nh1 {\n  font-size: 36px;\n  font-weight: 700;\n  color: #000;\n  margin: 0 0 10px 0;\n  letter-spacing: -1px;\n}\n\n.subtitle {\n  font-size: 16px;\n  color: #555;\n  margin: 0 0 15px 0;\n  font-weight: 400;\n}\n\n.badge {\n  display: inline-block;\n  background: #000;\n  color: #fff;\n  padding: 6px 20px;\n  font-size: 12px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin-bottom: 30px;\n}\n\n.highlights {\n  background: #f5f5f5;\n  padding: 25px 30px;\n  margin: 30px 0;\n  border-left: 4px solid #000;\n  font-size: 15px;\n  line-height: 1.7;\n}\n.highlights p { margin: 0; }\n\n.section-title {\n  font-size: 22px;\n  font-weight: 700;\n  color: #000;\n  margin: 50px 0 25px 0;\n  padding-bottom: 12px;\n  border-bottom: 3px solid #000;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.feature-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.feature-list li {\n  padding: 12px 0 12px 25px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n  line-height: 1.6;\n  position: relative;\n}\n.feature-list li::before {\n  content: \"—\";\n  position: absolute;\n  left: 0;\n  color: #000;\n  font-weight: bold;\n}\n\n.specs-table {\n  width: 100%;\n  border-collapse: collapse;\n  margin-top: 20px;\n}\n.specs-table td {\n  padding: 12px 15px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n}\n.specs-table td:first-child {\n  width: 45%;\n  color: #000;\n  font-weight: 600;\n}\n\n.compat-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 20px;\n  margin-top: 20px;\n}\n.compat-item {\n  background: #fff;\n  padding: 20px;\n  border: 2px solid #000;\n  text-align: center;\n}\n.compat-item strong {\n  font-size: 16px;\n  display: block;\n  margin-bottom: 5px;\n}\n.compat-item span {\n  font-size: 13px;\n  color: #555;\n}\n\n.integration {\n  background: #000;\n  color: #fff;\n  padding: 25px 30px;\n  margin: 40px 0;\n}\n.integration p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n.integration strong {\n  color: #fff;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.cta {\n  text-align: center;\n  margin-top: 50px;\n  padding-top: 40px;\n  border-top: 3px solid #000;\n}\n.btn {\n  display: inline-block;\n  padding: 16px 45px;\n  background: #000;\n  color: #fff;\n  text-decoration: none;\n  font-size: 14px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin: 0 10px 15px 0;\n  transition: all 0.3s ease;\n  border: 2px solid #000;\n  border-left: 4px solid #000;\n}\n.btn:hover {\n  background: #333;\n  border-color: #333;\n}\n.btn-outline {\n  background: transparent;\n  color: #000;\n}\n.btn-outline:hover {\n  background: #000;\n  color: #fff;\n}\n\n@media (max-width: 768px) {\n  h1 { font-size: 28px; }\n  .section-title { font-size: 18px; }\n  .btn { display: block; margin: 10px 0; }\n  .compat-grid { grid-template-columns: 1fr; }\n  .specs-table td:first-child { width: 50%; }\n}\n\u003c\/style\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48738814886107,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/H61_b4008caf-a5a6-474a-9ec2-f6fe9abd00e1.png?v=1777805634"},{"product_id":"p5-rack-gc-for-continuous-vocs-monitoring","title":"P5 Rack GC for Continuous VOCs Monitoring","description":"\u003c!-- P5 Rack GC for Continuous VOCs Monitoring - PROCESS GC SYSTEM ACCESSORY --\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"breadcrumb\"\u003e\n\u003cspan\u003eGC Systems\u003c\/span\u003e \u0026gt; \u003cspan\u003eProcess \/ Rack GC\u003c\/span\u003e \u0026gt; \u003cstrong\u003eP5 Accessory\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003ch1\u003eP5 Rack GC for Continuous VOCs Monitoring\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003e19\" Rack-Mounted Continuous Ambient Air Analyzer | NWSPEC GC Accessory Series\u003c\/p\u003e\n\u003cdiv class=\"badge\"\u003ePROCESS GC SYSTEM\u003c\/div\u003e\n\u003cdiv class=\"highlights\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eP5\u003c\/strong\u003e is a process-grade rack-mounted GC system designed for continuous 24\/7 monitoring of C2-C12 organic pollutants in ambient air. With ppt-level sensitivity, dual-stage enrichment, and full regulatory compliance (EU, EPA, China HJ), it serves as both a standalone air monitoring station and an integrated process control accessory for emissions management.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compliance\"\u003e\n\u003ch3\u003eRegulatory Compliance\u003c\/h3\u003e\n\u003cdiv class=\"compliance-grid\"\u003e\n\u003cdiv class=\"compliance-item\"\u003eEU 2002\/3\/EC\u003c\/div\u003e\n\u003cdiv class=\"compliance-item\"\u003eVDI 2100\u003c\/div\u003e\n\u003cdiv class=\"compliance-item\"\u003eEPA\/600-R-98\/161\u003c\/div\u003e\n\u003cdiv class=\"compliance-item\"\u003eChina HJ 1010-2018\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eProcess GC Applications\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003eAmbient air quality monitoring stations\u003c\/li\u003e\n\u003cli\u003eIndustrial emission continuous monitoring\u003c\/li\u003e\n\u003cli\u003ePAMS (Photochemical Assessment Monitoring Stations) C2-C12\u003c\/li\u003e\n\u003cli\u003eNMHC (Non-Methane Hydrocarbon) tracking\u003c\/li\u003e\n\u003cli\u003eBTEX (Benzene, Toluene, Ethylbenzene, Xylene) surveillance\u003c\/li\u003e\n\u003cli\u003eAliphatic hydrocarbon profiling\u003c\/li\u003e\n\u003cli\u003eChlorinated hydrocarbon detection (vinyl chloride, etc.)\u003c\/li\u003e\n\u003cli\u003eTHC (Total Hydrocarbon) measurement\u003c\/li\u003e\n\u003cli\u003eProcess plant perimeter monitoring\u003c\/li\u003e\n\u003cli\u003eUrban air quality network nodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSystem Features\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eppt-level sensitivity:\u003c\/strong\u003e Detection limit \u0026lt;0.1ppb for PAMS C2-C12 compounds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-stage enrichment:\u003c\/strong\u003e Pre-concentration module for ultra-trace VOCs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide carbon range:\u003c\/strong\u003e C2-C12 + custom VOC compounds configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in dilution:\u003c\/strong\u003e D2200 system for 0.1ppb calibration from 1ppm cylinder\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMass flow control:\u003c\/strong\u003e Built-in MFC and sampling pump for enrichment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact column oven:\u003c\/strong\u003e Ambient to 400°C programmable, fast cool-down\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-detector ready:\u003c\/strong\u003e Up to 3 detectors mountable (FID standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPC control:\u003c\/strong\u003e Electronic pressure controllers for all gas paths\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in industrial PC:\u003c\/strong\u003e 12.1\" touchscreen with pre-installed workstation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7×24 automation:\u003c\/strong\u003e Automatic running, calibration, and bake-out\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard protocols:\u003c\/strong\u003e MODBUS, Profibus, 4-20mA, RS485\/232, TCP\/IP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote access:\u003c\/strong\u003e Web browser control with IoT connectivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVPN support:\u003c\/strong\u003e Secure remote diagnostics and updates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData output:\u003c\/strong\u003e Excel, PDF, TXT formats with built-in calculation tools\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRaw data encryption:\u003c\/strong\u003e Secure data integrity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChromatogram overlay:\u003c\/strong\u003e Trend comparison and historical analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGPS integration:\u003c\/strong\u003e Location tagging available upon request\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater removal:\u003c\/strong\u003e Patented cooling + Nafion tube dual system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeans switch:\u003c\/strong\u003e Low-mass system for heart-cutting analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eH2 safety:\u003c\/strong\u003e Automatic shut-off when FID flame extinguishes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eSystem Specifications\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\" rack, 8U height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight \/ Depth:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8U, 670 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-240VAC, 50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Power:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC2-C12 + custom VOCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNMHC \/ THC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePre-concentration:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal desorption dual-stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColumn:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFused silica capillary with Deans switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOven Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40°C to 350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-40°C\/min (0.1°C\/min resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCarrier Gas:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH2\/N2 (default: H2 @ 5 bar, GC grade)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEPC Resolution:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFID (Flame Ionization Detector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLDL (PAMS C2-C12):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLDL (NMHC):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinearity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10⁷ (±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability (Area):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.5% (benzene at 1 ppb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability (RT):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1% (24hr, benzene)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Pump:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in diaphragm pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Flow:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-120 ml\/min (MFC controlled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Time:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-150 min adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnrichment Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-10°C programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesorption Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 380°C programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating-up Rate:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 120°C\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Sample Volume:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-1400 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePeltier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Split:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, programmable (low-mass system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTouch Screen:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.8\" or 12.1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniExpress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7×24 automatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Output:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExcel, PDF, TXT, custom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485, RS232, Ethernet×2, USB×3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4-20mA Output:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 255 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Output:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReady, alarm, error (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTubing Connector:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\" ferrule\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eCompatible GC Accessories\u003c\/h2\u003e\n\u003cdiv class=\"compat-grid\"\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eD2\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eDynamic Calibrator\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eT2\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThermodesorber\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eS6\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eTedlar Bag Sampler\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eS61\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eAutomatic Sample Vaporizer\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"integration\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e The P5 is designed as a complete air monitoring station in a 19\" rack format. The built-in D2200 dilution system enables automated calibration from 1ppm cylinders down to 0.1ppb—essential for ppt-level accuracy validation. When paired with the D2 dynamic calibrator, it achieves fully unattended 7×24 operation with automatic drift correction. All data exports via MODBUS\/Profibus to SCADA or environmental data platforms.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta\"\u003e\n\u003ca class=\"btn\" href=\"\/en-cn\/pages\/contact\"\u003e\u003cspan style=\"color: rgb(255, 255, 255);\"\u003eRequest Process GC Quote\u003c\/span\u003e\u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\n.product-container {\n  max-width: 900px;\n  margin: 0 auto;\n  padding: 40px 20px;\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n  font-size: 14px;\n  line-height: 1.6;\n  color: #222;\n  background: #fff;\n}\n\n.breadcrumb {\n  font-size: 13px;\n  color: #666;\n  margin-bottom: 20px;\n  padding: 10px 0;\n  border-bottom: 1px solid #eee;\n}\n.breadcrumb span { color: #999; }\n.breadcrumb strong { color: #000; }\n\nh1 {\n  font-size: 36px;\n  font-weight: 700;\n  color: #000;\n  margin: 0 0 10px 0;\n  letter-spacing: -1px;\n}\n\n.subtitle {\n  font-size: 16px;\n  color: #555;\n  margin: 0 0 15px 0;\n  font-weight: 400;\n}\n\n.badge {\n  display: inline-block;\n  background: #000;\n  color: #fff;\n  padding: 6px 20px;\n  font-size: 12px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin-bottom: 30px;\n}\n\n.highlights {\n  background: #f5f5f5;\n  padding: 25px 30px;\n  margin: 30px 0;\n  border-left: 4px solid #000;\n  font-size: 15px;\n  line-height: 1.7;\n}\n.highlights p { margin: 0; }\n\n.compliance {\n  background: #000;\n  color: #fff;\n  padding: 25px 30px;\n  margin: 30px 0;\n}\n.compliance h3 {\n  margin: 0 0 20px 0;\n  font-size: 16px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n.compliance-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(180px, 1fr));\n  gap: 15px;\n}\n.compliance-item {\n  background: #fff;\n  color: #000;\n  padding: 15px;\n  text-align: center;\n  font-weight: 700;\n  font-size: 14px;\n}\n\n.section-title {\n  font-size: 22px;\n  font-weight: 700;\n  color: #000;\n  margin: 50px 0 25px 0;\n  padding-bottom: 12px;\n  border-bottom: 3px solid #000;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.feature-list {\n  list-style: none;\n  padding: 0;\n  margin: 0;\n}\n.feature-list li {\n  padding: 12px 0 12px 25px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n  line-height: 1.6;\n  position: relative;\n}\n.feature-list li::before {\n  content: \"—\";\n  position: absolute;\n  left: 0;\n  color: #000;\n  font-weight: bold;\n}\n\n.specs-table {\n  width: 100%;\n  border-collapse: collapse;\n  margin-top: 20px;\n}\n.specs-table td {\n  padding: 12px 15px;\n  border-bottom: 1px solid #eee;\n  font-size: 14px;\n}\n.specs-table td:first-child {\n  width: 45%;\n  color: #000;\n  font-weight: 600;\n}\n\n.compat-grid {\n  display: grid;\n  grid-template-columns: repeat(auto-fit, minmax(200px, 1fr));\n  gap: 20px;\n  margin-top: 20px;\n}\n.compat-item {\n  background: #fff;\n  padding: 20px;\n  border: 2px solid #000;\n  text-align: center;\n}\n.compat-item strong {\n  font-size: 16px;\n  display: block;\n  margin-bottom: 5px;\n}\n.compat-item span {\n  font-size: 13px;\n  color: #555;\n}\n\n.integration {\n  background: #000;\n  color: #fff;\n  padding: 25px 30px;\n  margin: 40px 0;\n}\n.integration p {\n  margin: 0;\n  font-size: 14px;\n  line-height: 1.6;\n}\n.integration strong {\n  color: #fff;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n}\n\n.cta {\n  text-align: center;\n  margin-top: 50px;\n  padding-top: 40px;\n  border-top: 3px solid #000;\n}\n.btn {\n  display: inline-block;\n  padding: 16px 45px;\n  background: #000;\n  color: #fff;\n  text-decoration: none;\n  font-size: 14px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 2px;\n  margin: 0 10px 15px 0;\n  transition: all 0.3s ease;\n  border: 2px solid #000;\n  border-left: 4px solid #000;\n}\n.btn:hover {\n  background: #333;\n  border-color: #333;\n}\n.btn-outline {\n  background: transparent;\n  color: #000;\n}\n.btn-outline:hover {\n  background: #000;\n  color: #fff;\n}\n\n@media (max-width: 768px) {\n  h1 { font-size: 28px; }\n  .section-title { font-size: 18px; }\n  .btn { display: block; margin: 10px 0; }\n  .compat-grid { grid-template-columns: 1fr; }\n  .compliance-grid { grid-template-columns: 1fr; }\n  .specs-table td:first-child { width: 50%; }\n}\n\u003c\/style\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48738835366107,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/P5.png?v=1777803767"},{"product_id":"gas-purifiers-and-traps-for-gc-systems","title":"Gas Purifiers and Traps for GC Systems","description":"\u003cstyle\u003e\n  .product-container { max-width: 900px; margin: 0 auto; padding: 40px 20px; font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif; font-size: 14px; line-height: 1.6; color: #222; background: #fff; }\n  .breadcrumb { font-size: 13px; color: #666; margin-bottom: 20px; padding: 10px 0; border-bottom: 1px solid #eee; }\n  .breadcrumb span { color: #999; }\n  .breadcrumb strong { color: #000; }\n  h1 { font-size: 36px; font-weight: 700; color: #000; margin: 0 0 10px 0; letter-spacing: -1px; }\n  .subtitle { font-size: 16px; color: #555; margin: 0 0 15px 0; font-weight: 400; }\n  .badge { display: inline-block; background: #000; color: #fff; padding: 6px 20px; font-size: 12px; font-weight: 700; text-transform: uppercase; letter-spacing: 2px; margin-bottom: 30px; }\n  .highlights { background: #f5f5f5; padding: 25px 30px; margin: 30px 0; border-left: 4px solid #000; font-size: 15px; line-height: 1.7; }\n  .highlights p { margin: 0; }\n  .section-title { font-size: 22px; font-weight: 700; color: #000; margin: 50px 0 25px 0; padding-bottom: 12px; border-bottom: 3px solid #000; text-transform: uppercase; letter-spacing: 1px; }\n  .feature-list { list-style: none; padding: 0; margin: 0; }\n  .feature-list li { padding: 12px 0 12px 25px; border-bottom: 1px solid #eee; font-size: 14px; line-height: 1.6; position: relative; }\n  .feature-list li::before { content: \"—\"; position: absolute; left: 0; color: #000; font-weight: bold; }\n  .specs-table { width: 100%; border-collapse: collapse; margin-top: 20px; }\n  .specs-table td { padding: 12px 15px; border-bottom: 1px solid #eee; font-size: 14px; }\n  .specs-table td:first-child { width: 45%; color: #000; font-weight: 600; }\n  .compat-grid { display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 20px; margin-top: 20px; }\n  .compat-item { background: #fff; padding: 20px; border: 2px solid #000; text-align: center; }\n  .compat-item strong { font-size: 16px; display: block; margin-bottom: 5px; }\n  .compat-item span { font-size: 13px; color: #555; }\n  .integration { background: #000; color: #fff; padding: 25px 30px; margin: 40px 0; }\n  .integration p { margin: 0; font-size: 14px; line-height: 1.6; }\n  .integration strong { color: #fff; text-transform: uppercase; letter-spacing: 1px; }\n  .cta { text-align: center; margin-top: 50px; padding-top: 40px; border-top: 3px solid #000; }\n  .btn { display: inline-block; padding: 16px 45px; background: #000; color: #fff; text-decoration: none; font-size: 14px; font-weight: 700; text-transform: uppercase; letter-spacing: 2px; margin: 0 10px 15px 0; transition: all 0.3s ease; border: 2px solid #000; border-left: 4px solid #000; }\n  .btn:hover { background: #333; border-color: #333; }\n  .btn-outline { background: transparent; color: #000; }\n  .btn-outline:hover { background: #000; color: #fff; }\n  @media (max-width: 768px) { h1 { font-size: 28px; } .section-title { font-size: 18px; } .btn { display: block; margin: 10px 0; } .compat-grid { grid-template-columns: 1fr; } .specs-table td:first-child { width: 50%; } }\n\u003c\/style\u003e\n\u003cdiv class=\"product-container\"\u003e\n\u003cdiv class=\"breadcrumb\"\u003e\n\u003cspan\u003eGC Systems\u003c\/span\u003e \u0026gt; \u003cspan\u003eGas Management\u003c\/span\u003e \u0026gt; \u003cstrong\u003eGas Purifiers\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003ch1\u003eGas Purifiers and Traps\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eCarrier Gas Purification for GC Systems | NWSPEC GC Accessory Series\u003c\/p\u003e\n\u003cdiv class=\"badge\"\u003eGAS MANAGEMENT\u003c\/div\u003e\n\u003cdiv class=\"highlights\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eGas Purifiers and Traps\u003c\/strong\u003e remove common pollutants such as oxygen, moisture, and hydrocarbon compounds from carrier gas for GC. Purifying the carrier gas with oxygen and moisture traps can extend the lifespan of the chromatographic column and protect your instrument. Meanwhile, removing hydrocarbon compounds helps improve detector baseline stability and sensitivity. The materials filled inside are strictly tested to ensure that even if the gas supply cylinder is of the 99.995% grade, the trap outlet can reach the \u003cstrong\u003e\"chromatographic grade\" of 99.9999%\u003c\/strong\u003e for the carrier gas. All traps are available in 1\/8\" and 1\/4\" fitting sizes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eGC Applications\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003eCarrier gas purification for GC systems\u003c\/li\u003e\n\u003cli\u003eDetector gas purification (FID, TCD, ECD)\u003c\/li\u003e\n\u003cli\u003eGC\/MS carrier gas ultra-purification\u003c\/li\u003e\n\u003cli\u003eLC\/MS nitrogen gas purification\u003c\/li\u003e\n\u003cli\u003eHigh-throughput laboratory gas supply\u003c\/li\u003e\n\u003cli\u003eProcess GC continuous gas purification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eProduct Range\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003e750cc Universal Purifiers (Big Universal Trap):\u003c\/strong\u003e Helium P7000-30007\/34007, Hydrogen P7000-30008\/34008, Nitrogen P7000-30006\/34006, Air P7000-30001\/34001, Nitrogen for LC\/MS P7000-30106\/34106\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200cc Mini Gas Traps:\u003c\/strong\u003e Moisture M6000-62008\/64008, Hydrocarbon M6000-62006\/64006, Oxygen M6000-62007\/64007, Hydrocarbon \u0026amp; Moisture M6000-30002\/34002\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitting sizes:\u003c\/strong\u003e 1\/8\" and 1\/4\" available for all models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003ePurifier Features\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge-capacity universal trap:\u003c\/strong\u003e 750cc super-large adsorbent material in multi-layer column bed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVertical installation:\u003c\/strong\u003e Install in front of gas purification system to further increase trapping capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal for large-volume purification:\u003c\/strong\u003e Suitable for high-throughput laboratories\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCombined gas trap:\u003c\/strong\u003e Remove moisture, oxygen, and\/or organic matter with a single trap\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated traps:\u003c\/strong\u003e Select different types and sizes for your own laboratory needs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutlet purity:\u003c\/strong\u003e Chromatographic grade 99.9999% from 99.995% inlet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollutant removal:\u003c\/strong\u003e O₂, H₂O, hydrocarbons to \u0026lt;1-3 ppb level\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"section-title\"\u003eTrapping Capacity\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUniversal Trap (200cc):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3L O₂ \/ 13g H₂O \/ 6.5g Hydrocarbon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUniversal Trap (750cc):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2L O₂ \/ 50g H₂O \/ 25g Hydrocarbon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture Trap (200cc):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13g Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHydrocarbon Trap (200cc):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5g Hydrocarbon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eOutlet Gas Purity (Inlet \u0026lt;50ppm, better than 99.995%)\u003c\/h2\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHelium purifier:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-methane hydrocarbons \u0026lt;1ppb, CO \u0026lt;1ppb, H₂O \u0026lt;1ppb, CO₂ \u0026lt;1ppb, O₂ \u0026lt;3ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHydrogen purifier:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-methane hydrocarbons \u0026lt;1ppb, CO \u0026lt;1ppb, H₂O \u0026lt;1ppb, CO₂ \u0026lt;1ppb, O₂ \u0026lt;3ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir purifier:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-methane hydrocarbons \u0026lt;1ppb, H₂O \u0026lt;1ppb, CO₂ \u0026lt;3ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrogen purifier:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-methane hydrocarbons \u0026lt;1ppb, CO \u0026lt;1ppb, H₂O \u0026lt;1ppb, CO₂ \u0026lt;1ppb, O₂ \u0026lt;3ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrogen purifier for LC\/MS:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-methane hydrocarbons \u0026lt;25ppb, CO \u0026lt;25ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture trap:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eH₂O \u0026lt;1ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHydrocarbon trap:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-methane hydrocarbons \u0026lt;3ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOxygen trap:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eO₂ \u0026lt;1ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eCompatible GC Systems\u003c\/h2\u003e\n\u003cdiv class=\"compat-grid\"\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC60\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eLab GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC30\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCompact GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eGC20\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEntry GC System\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eP6\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePortable GC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eP5\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eRack GC (continuous)\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"compat-item\"\u003e\n\u003cstrong\u003eThird-party GC\/GC-MS\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eVia standard fitting\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"integration\"\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e NWSPEC Gas Purifiers and Traps connect directly to GC carrier gas lines via 1\/8\" or 1\/4\" fittings. The 750cc Universal Purifier is recommended for continuous monitoring systems (P5 rack GC) and high-throughput laboratories, while the 200cc Mini Gas Trap is ideal for single GC setups and portable systems (P6). All purifiers are maintenance-free until saturation indicators show replacement is needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta\"\u003e\n\u003ca class=\"btn\" href=\"\/en-cn\/pages\/contact\"\u003e\u003cspan style=\"color: rgb(255, 255, 255);\"\u003eRequest Purifier Quote\u003c\/span\u003e\u003c\/a\u003e \u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48738894315739,"sku":null,"price":1.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/gaspurifiers_0f72278b-3ce3-4cff-916e-57a8b10b446f.png?v=1777803811"}],"url":"https:\/\/nwspec.com\/en-cn\/collections\/gc-accessories.oembed","provider":"NWSPEC","version":"1.0","type":"link"}