{"title":"Raman Spectrometer","description":"\u003cp\u003eResearch-grade and portable Raman spectrometers for materials science, electrochemistry, energy research, and industrial analysis. Includes the world-first integrated EC-Raman microscope for in-situ electrochemical characterization.\u003c\/p\u003e","products":[{"product_id":"ramf-series-field-raman-spectrometer","title":"RamF Series Field Raman Spectrometer | 532 nm \u0026 785 nm","description":"\u003cstyle\u003e\n  .ramf-guide {\n    max-width: 1200px;\n    margin: 0 auto;\n    padding: 40px 20px;\n    font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, 'Helvetica Neue', Arial, sans-serif;\n    color: #1a1a1a;\n    background: #fff;\n    box-sizing: border-box;\n  }\n  .ramf-guide * { box-sizing: border-box; }\n  .ramf-guide h1 { font-size: 34px; font-weight: 700; margin: 0 0 12px 0; color: #000; line-height: 1.2; }\n  .ramf-guide .subtitle { font-size: 17px; color: #555; margin: 0 0 28px 0; line-height: 1.6; }\n\n  \/* HERO *\/\n  .ramf-guide .hero-box { background: #f7f7f7; border: 2px solid #1a1a1a; padding: 28px 32px; margin: 28px 0; }\n  .ramf-guide .hero-box p { font-size: 16px; line-height: 1.7; margin: 0; color: #333; }\n\n  \/* MODEL SELECTOR *\/\n  .ramf-guide .model-grid { display: grid; grid-template-columns: repeat(2, 1fr); gap: 24px; margin: 28px 0; }\n  .ramf-guide .model-card { border: 2px solid #1a1a1a; padding: 28px; background: #fff; }\n  .ramf-guide .model-card .model-badge { display: inline-block; background: #1a1a1a; color: #fff; padding: 4px 14px; font-size: 12px; font-weight: 700; letter-spacing: 0.5px; text-transform: uppercase; margin-bottom: 14px; }\n  .ramf-guide .model-card h3 { font-size: 20px; font-weight: 700; color: #000; margin: 0 0 10px 0; line-height: 1.3; }\n  .ramf-guide .model-card .model-wavelength { font-size: 32px; font-weight: 800; color: #000; font-family: 'Courier New', monospace; margin: 0 0 14px 0; }\n  .ramf-guide .model-card p { font-size: 14px; color: #444; line-height: 1.6; margin: 0 0 16px 0; }\n  .ramf-guide .model-card .best-for { font-size: 13px; font-weight: 700; color: #000; text-transform: uppercase; letter-spacing: 0.3px; }\n  .ramf-guide .model-card .best-for span { font-weight: 400; color: #333; text-transform: none; letter-spacing: 0; }\n\n  \/* SHARED FEATURES *\/\n  .ramf-guide h2 { font-size: 22px; font-weight: 700; color: #000; border-bottom: 3px solid #000; padding-bottom: 10px; margin: 36px 0 20px 0; line-height: 1.3; }\n  .ramf-guide .feature-list { margin: 0; padding: 0; list-style: none; }\n  .ramf-guide .feature-list li { padding: 14px 0 14px 26px; border-bottom: 1px solid #eee; font-size: 15px; line-height: 1.6; position: relative; color: #333; }\n  .ramf-guide .feature-list li:before { content: '→'; position: absolute; left: 0; top: 14px; color: #000; font-weight: 700; }\n  .ramf-guide .feature-list li strong { color: #000; font-weight: 700; }\n\n  \/* SPECS TABLE *\/\n  .ramf-guide .specs-scroll { width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0; }\n  .ramf-guide .specs-table { width: 100%; min-width: 600px; border-collapse: collapse; font-size: 14px; }\n  .ramf-guide .specs-table thead tr { background: #f0f0f0; }\n  .ramf-guide .specs-table thead th { padding: 12px 16px; text-align: left; font-weight: 700; font-size: 13px; border-bottom: 2px solid #000; }\n  .ramf-guide .specs-table thead th.col-532 { background: #e8e8e8; border-left: 3px solid #000; }\n  .ramf-guide .specs-table thead th.col-785 { background: #f0f0f0; }\n  .ramf-guide .specs-table tbody tr { border-bottom: 1px solid #ddd; }\n  .ramf-guide .specs-table tbody tr:nth-child(even) { background: #fafafa; }\n  .ramf-guide .specs-table td { padding: 12px 16px; vertical-align: top; line-height: 1.5; }\n  .ramf-guide .specs-table td:first-child { font-weight: 600; color: #000; font-size: 13px; width: 30%; }\n  .ramf-guide .specs-table td.col-532 { border-left: 3px solid #e0e0e0; }\n\n  \/* APPLICATIONS *\/\n  .ramf-guide .app-grid { display: grid; grid-template-columns: repeat(3, 1fr); gap: 16px; margin: 20px 0; }\n  .ramf-guide .app-card { border: 1px solid #ddd; border-left: 4px solid #1a1a1a; padding: 16px 18px; background: #fff; }\n  .ramf-guide .app-card h4 { font-size: 14px; font-weight: 700; color: #000; margin: 0 0 6px 0; text-transform: uppercase; letter-spacing: 0.3px; }\n  .ramf-guide .app-card p { font-size: 13px; color: #444; margin: 0; line-height: 1.5; }\n\n  \/* CTA *\/\n  .ramf-guide .cta-box { background: #f5f5f5; border-left: 4px solid #000; padding: 28px 32px; margin: 36px 0; text-align: center; }\n  .ramf-guide .cta-box h3 { font-size: 20px; font-weight: 700; color: #000; margin: 0 0 10px 0; }\n  .ramf-guide .cta-box p { font-size: 15px; color: #555; margin: 0 0 18px 0; line-height: 1.6; }\n  .ramf-guide .cta-button { display: inline-block; background: #1a1a1a; color: #fff; padding: 13px 30px; font-size: 15px; font-weight: 600; text-decoration: none; border: 2px solid #1a1a1a; transition: all 0.2s; }\n  .ramf-guide .cta-button:hover { background: #fff; color: #1a1a1a; }\n\n  \/* RESPONSIVE *\/\n  @media (max-width: 768px) {\n    .ramf-guide { padding: 24px 16px; }\n    .ramf-guide h1 { font-size: 26px; }\n    .ramf-guide .model-grid { grid-template-columns: 1fr; }\n    .ramf-guide .app-grid { grid-template-columns: 1fr; }\n    .ramf-guide h2 { font-size: 19px; }\n    .ramf-guide .hero-box { padding: 20px; }\n    .ramf-guide .cta-box { padding: 20px; }\n  }\n  @media (max-width: 480px) {\n    .ramf-guide { padding: 16px 12px; }\n    .ramf-guide h1 { font-size: 22px; }\n    .ramf-guide .model-card .model-wavelength { font-size: 26px; }\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"ramf-guide\"\u003e\n\n\u003ch1\u003eRamF Series Field Raman Spectrometer\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eCompact, mobile Raman spectroscopy for on-site chemical identification — no external PC required\u003c\/p\u003e\n\n\u003cdiv class=\"hero-box\"\u003e\n\u003cp\u003eThe RamF Series delivers laboratory-grade Raman performance in a 6 kg, suitcase-sized enclosure. With a built-in computer, fiber-coupled probe, spectral database, and analysis software all integrated into one ruggedized unit, the RamF is ready to deploy at customs checkpoints, jewelry counters, pharmaceutical production lines, or remote field locations. Two wavelength options cover the full range of field identification applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- MODEL COMPARISON --\u003e\n\u003ch2\u003eChoose Your Model\u003c\/h2\u003e\n\u003cdiv class=\"model-grid\"\u003e\n\u003cdiv class=\"model-card\"\u003e\n\u003cspan class=\"model-badge\"\u003eRamF532\u003c\/span\u003e\n\u003cdiv class=\"model-wavelength\"\u003e532 nm\u003c\/div\u003e\n\u003ch3\u003eHigh-Efficiency \u0026amp; Gemstone Analysis\u003c\/h3\u003e\n\u003cp\u003e532 nm excitation delivers the highest Raman scattering efficiency and superior spatial resolution. Optimized for gemstone and diamond analysis where signal strength and spatial precision are critical.\u003c\/p\u003e\n\u003cp class=\"best-for\"\u003eBest for: \u003cspan\u003eGemstone authentication, diamond grading, treatment detection, high-sensitivity material identification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"model-card\"\u003e\n\u003cspan class=\"model-badge\"\u003eRamF785\u003c\/span\u003e\n\u003cdiv class=\"model-wavelength\"\u003e785 nm\u003c\/div\u003e\n\u003ch3\u003eReduced Fluorescence \u0026amp; Routine Screening\u003c\/h3\u003e\n\u003cp\u003e785 nm near-infrared excitation dramatically reduces sample fluorescence, enabling clean spectra from complex matrices. The preferred choice for pharmaceutical, food safety, and security screening applications.\u003c\/p\u003e\n\u003cp class=\"best-for\"\u003eBest for: \u003cspan\u003eDrug screening, pharmaceutical QC, food adulteration, hazardous material identification, security inspection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- SHARED FEATURES --\u003e\n\u003ch2\u003eShared Features — Both Models\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Portability:\u003c\/strong\u003e 6 kg integrated enclosure, 508 × 373 × 147 mm footprint, 12V DC field power — operable from battery or vehicle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-in-One Design:\u003c\/strong\u003e Built-in computer, laser control, detection system, spectral database, and analysis software — no external PC required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Sampling:\u003c\/strong\u003e 1 m armored fiber-coupled probe for non-contact, non-destructive measurements in any environment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Performance Detector:\u003c\/strong\u003e Cooled CMOS, 2048 pixels, ~440:1 SNR, 16-bit dynamic range, 1 ms – 15 min integration time\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e 0°C – 45°C operating temperature, −10°C – 55°C storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- SPECS TABLE --\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"specs-scroll\"\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth class=\"col-532\"\u003eRamF532 (532 nm)\u003c\/th\u003e\n\u003cth class=\"col-785\"\u003eRamF785 (785 nm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Wavelength\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e532 nm (±1 nm, ≤0.2 nm linewidth)\u003c\/td\u003e\n\u003ctd\u003e785 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser Output Power\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e0–50 mW adjustable\u003c\/td\u003e\n\u003ctd\u003e0–50 mW adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Range\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e200–4000 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e200–3300 cm⁻¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Resolution\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e~8 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e~8 cm⁻¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Transmission\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e60–70%\u003c\/td\u003e\n\u003ctd\u003e60–70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e~0.29% @ 532 nm\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003eCooled CMOS, 2048 pixels\u003c\/td\u003e\n\u003ctd\u003eCooled CMOS, 2048 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSNR\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e~440:1\u003c\/td\u003e\n\u003ctd\u003e~440:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e16-bit A\/D\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration Time\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e1 ms – 15 min\u003c\/td\u003e\n\u003ctd\u003e1 ms – 15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Probe\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e1 m armored\u003c\/td\u003e\n\u003ctd\u003e1 m armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e12 VDC @ 5 A\u003c\/td\u003e\n\u003ctd\u003e12 VDC @ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e508 × 373 × 147 mm\u003c\/td\u003e\n\u003ctd\u003e508 × 373 × 147 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e~6 kg\u003c\/td\u003e\n\u003ctd\u003e~6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd class=\"col-532\"\u003e0°C – 45°C\u003c\/td\u003e\n\u003ctd\u003e0°C – 45°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2\u003eApplication Areas\u003c\/h2\u003e\n\u003cdiv class=\"app-grid\"\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch4\u003eGemstone \u0026amp; Jewelry\u003c\/h4\u003e\n\u003cp\u003eDiamond grading, treatment detection, mineral identification, authenticity verification. \u003cem\u003eRamF532 recommended.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch4\u003eSecurity \u0026amp; Customs\u003c\/h4\u003e\n\u003cp\u003eDrug screening, hazardous materials, biochemical threats, law enforcement field identification. \u003cem\u003eRamF785 recommended.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch4\u003ePharmaceutical\u003c\/h4\u003e\n\u003cp\u003eRaw material QC, counterfeit detection, illegal additive screening, herbal composition analysis. \u003cem\u003eRamF785 recommended.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch4\u003eFood Safety\u003c\/h4\u003e\n\u003cp\u003eAdulteration detection, herbal verification, food authenticity, ingredient screening. \u003cem\u003eRamF785 recommended.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch4\u003eR\u0026amp;D \u0026amp; Medical\u003c\/h4\u003e\n\u003cp\u003eDNA identification, metabolite analysis, cancer cell detection, spectroscopic research.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch4\u003eIndustrial \u0026amp; Field\u003c\/h4\u003e\n\u003cp\u003eOn-site material verification, incoming goods inspection, process monitoring, environmental screening.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"cta-box\"\u003e\n\u003ch3\u003eSelect Your Model \u0026amp; Request a Quote\u003c\/h3\u003e\n\u003cp\u003eChoose RamF532 or RamF785 above, then contact our team for pricing, application support, and demo arrangements.\u003c\/p\u003e\n\u003ca class=\"cta-button\" href=\"\/en-cn\/pages\/contact\"\u003eRequest Technical Consultation\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":47490548072667,"sku":"RamF532","price":17500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/NW-RM-785_MobileRamanSpectrometer_image_1.png?v=1771054297"},{"product_id":"integrated-raman-spectrometer-yhu-785","title":"Raman Microscope","description":"\u003cstyle\u003e\n  .product-section {\n    max-width: 1200px;\n    margin: 0 auto;\n    padding: 40px 20px;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n    color: #000;\n    line-height: 1.6;\n  }\n\n  .product-section h1 {\n    font-size: 2.5em;\n    font-weight: 700;\n    margin-bottom: 24px;\n    color: #1a1a1a;\n    letter-spacing: -0.02em;\n  }\n\n  .product-section .intro {\n    font-size: 1.15em;\n    margin-bottom: 16px;\n    color: #1a1a1a;\n    font-weight: 500;\n  }\n\n  .product-section .secondary {\n    font-size: 1em;\n    margin-bottom: 32px;\n    color: #333;\n  }\n\n  .highlights-box {\n    background: #f5f5f5;\n    border-left: 4px solid #000;\n    padding: 24px 28px;\n    margin: 32px 0;\n  }\n\n  .highlights-box h3 {\n    margin: 0 0 16px 0;\n    font-size: 1.1em;\n    font-weight: 700;\n    color: #1a1a1a;\n    text-transform: uppercase;\n    letter-spacing: 0.05em;\n  }\n\n  .highlights-box ul {\n    margin: 0;\n    padding-left: 20px;\n  }\n\n  .highlights-box li {\n    margin-bottom: 8px;\n    color: #333;\n  }\n\n  .product-section h2 {\n    font-size: 1.5em;\n    font-weight: 700;\n    margin: 48px 0 24px 0;\n    padding-bottom: 12px;\n    border-bottom: 3px solid #000;\n    color: #1a1a1a;\n  }\n\n  .guide-section {\n    margin: 32px 0;\n  }\n\n  .guide-section h3 {\n    font-size: 1.2em;\n    font-weight: 700;\n    margin-bottom: 16px;\n    color: #1a1a1a;\n    display: flex;\n    align-items: center;\n    gap: 12px;\n  }\n\n  .guide-section h3::before {\n    content: \"\";\n    display: inline-block;\n    width: 8px;\n    height: 8px;\n    background: #000;\n    flex-shrink: 0;\n  }\n\n  .guide-section p {\n    margin-bottom: 16px;\n    color: #333;\n  }\n\n  .choice-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 24px 0;\n    box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n  }\n\n  .choice-table thead {\n    background: #1a1a1a;\n    color: #fff;\n  }\n\n  .choice-table th {\n    padding: 14px 16px;\n    text-align: left;\n    font-weight: 600;\n    border: 1px solid #1a1a1a;\n  }\n\n  .choice-table td {\n    padding: 12px 16px;\n    border: 1px solid #ddd;\n    color: #333;\n    vertical-align: top;\n  }\n\n  .choice-table tbody tr:nth-child(even) {\n    background: #fafafa;\n  }\n\n  .choice-table td:first-child {\n    font-weight: 600;\n    color: #000;\n    width: 25%;\n  }\n\n  .choice-table td:nth-child(2) {\n    width: 35%;\n  }\n\n  .choice-table td:nth-child(3) {\n    width: 40%;\n  }\n\n  .recommendation-box {\n    background: #f5f5f5;\n    border-left: 4px solid #000;\n    padding: 20px 24px;\n    margin: 20px 0;\n  }\n\n  .recommendation-box strong {\n    color: #1a1a1a;\n    font-weight: 700;\n  }\n\n  .application-grid {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n    gap: 20px;\n    margin: 24px 0;\n  }\n\n  .application-card {\n    border-left: 3px solid #000;\n    padding-left: 16px;\n  }\n\n  .application-card strong {\n    display: block;\n    margin-bottom: 6px;\n    color: #1a1a1a;\n    font-weight: 600;\n  }\n\n  .application-card p {\n    margin: 0;\n    color: #555;\n    font-size: 0.95em;\n  }\n\n  .model-comparison {\n    margin: 24px 0;\n  }\n\n  .model-card {\n    border: 2px solid #1a1a1a;\n    padding: 24px;\n    margin-bottom: 20px;\n    background: #fff;\n  }\n\n  .model-card h4 {\n    font-size: 1.3em;\n    font-weight: 700;\n    margin: 0 0 12px 0;\n    color: #1a1a1a;\n    border-bottom: 2px solid #000;\n    padding-bottom: 8px;\n  }\n\n  .model-card .best-for {\n    font-weight: 600;\n    color: #000;\n    margin-bottom: 12px;\n  }\n\n  .model-card ul {\n    margin: 0;\n    padding-left: 20px;\n  }\n\n  .model-card li {\n    margin-bottom: 6px;\n    color: #333;\n  }\n\n  .quick-guide {\n    background: #1a1a1a;\n    color: #fff;\n    padding: 24px 28px;\n    margin: 32px 0;\n  }\n\n  .quick-guide h3 {\n    margin: 0 0 16px 0;\n    font-size: 1.2em;\n    font-weight: 700;\n    color: #fff;\n  }\n\n  .quick-guide ol {\n    margin: 0;\n    padding-left: 20px;\n  }\n\n  .quick-guide li {\n    margin-bottom: 10px;\n    color: #e0e0e0;\n  }\n\n  .quick-guide li strong {\n    color: #fff;\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"product-section\"\u003e\n  \u003ch1\u003eRaman Microscope Selection Guide\u003c\/h1\u003e\n  \n  \u003cp class=\"intro\"\u003e\n    \u003cstrong\u003eChoose the optimal Raman microscopy configuration\u003c\/strong\u003e for your analytical requirements. This guide helps you select the right excitation wavelength and system specifications based on your sample type, application field, and performance needs.\n  \u003c\/p\u003e\n  \n  \u003cp class=\"secondary\"\u003e\n    Raman Microscope integrates high-resolution optical microscopy with precision Raman spectroscopy for non-destructive chemical imaging and microanalysis.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"highlights-box\"\u003e\n    \u003ch3\u003eKey Decision Factors\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eExcitation wavelength\u003c\/strong\u003e — Critical for fluorescence control and sample compatibility\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eSample type\u003c\/strong\u003e — Organic, inorganic, biological, or forensic materials\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eApplication environment\u003c\/strong\u003e — Laboratory precision vs. field portability\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eDetection sensitivity\u003c\/strong\u003e — Signal strength vs. background interference\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eStep 1: Select Your Excitation Wavelength\u003c\/h2\u003e\n  \n  \u003cdiv class=\"guide-section\"\u003e\n    \u003cp\u003eThe excitation wavelength is the most critical choice for Raman microscopy. Select based on your sample's fluorescence properties and Raman scattering efficiency:\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003ctable class=\"choice-table\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth\u003eWavelength\u003c\/th\u003e\n        \u003cth\u003eBest For\u003c\/th\u003e\n        \u003cth\u003eAvoid When\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003e532 nm (Green)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eInorganic materials, minerals, carbon materials, silicon, semiconductors. High Raman scattering efficiency.\u003c\/td\u003e\n        \u003ctd\u003eSamples with strong fluorescence (many organics, dyes, biological tissues). May cause photobleaching in sensitive samples.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003e785 nm (NIR)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eGeneral-purpose applications. Good balance of sensitivity and fluorescence suppression. Organic chemicals, polymers, pharmaceuticals.\u003c\/td\u003e\n        \u003ctd\u003eHighly fluorescent biological samples or deeply colored materials where 785 nm still excites fluorescence.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003e1064 nm (NIR)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eHighly fluorescent samples, biological tissues, forensic samples, dark-colored materials, art\/historical artifacts. Maximum fluorescence suppression.\u003c\/td\u003e\n        \u003ctd\u003eWhen highest sensitivity is required (Raman intensity decreases with λ⁴). Inorganic materials where 532 nm performs better.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv class=\"recommendation-box\"\u003e\n    \u003cstrong\u003eRecommendation:\u003c\/strong\u003e Start with 785 nm for general analytical work. Choose 532 nm for inorganics\/carbon research. Select 1064 nm for forensic, biological, or highly fluorescent samples.\n  \u003c\/div\u003e\n\n  \u003ch2\u003eStep 2: Match System to Your Application\u003c\/h2\u003e\n\n  \u003cdiv class=\"application-grid\"\u003e\n    \u003cdiv class=\"application-card\"\u003e\n      \u003cstrong\u003eSecurity \u0026amp; Forensics\u003c\/strong\u003e\n      \u003cp\u003eExplosives, narcotics, toxic substances identification. \u003cem\u003eRecommend: 785 nm or 1064 nm for unknown samples with variable fluorescence.\u003c\/em\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"application-card\"\u003e\n      \u003cstrong\u003ePharmaceutical \u0026amp; Food\u003c\/strong\u003e\n      \u003cp\u003eAPI identification, counterfeit detection, quality control. \u003cem\u003eRecommend: 785 nm for general QC; 1064 nm for complex formulations.\u003c\/em\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"application-card\"\u003e\n      \u003cstrong\u003eMaterials Science\u003c\/strong\u003e\n      \u003cp\u003eCarbon nanotubes, graphene, semiconductors, thin films. \u003cem\u003eRecommend: 532 nm for maximum signal; 785 nm for general characterization.\u003c\/em\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"application-card\"\u003e\n      \u003cstrong\u003eGeology \u0026amp; Mineralogy\u003c\/strong\u003e\n      \u003cp\u003eMineral identification, inclusion analysis, field prospecting. \u003cem\u003eRecommend: 532 nm for mineral fingerprinting; portable configuration for field use.\u003c\/em\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"application-card\"\u003e\n      \u003cstrong\u003eLife Science \u0026amp; Medical\u003c\/strong\u003e\n      \u003cp\u003eCell analysis, tissue imaging, metabolite detection. \u003cem\u003eRecommend: 1064 nm essential for biological fluorescence suppression.\u003c\/em\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"application-card\"\u003e\n      \u003cstrong\u003eArt \u0026amp; Cultural Heritage\u003c\/strong\u003e\n      \u003cp\u003ePigment identification, authentication, aging analysis. \u003cem\u003eRecommend: 1064 nm for historical pigments and binders without damage.\u003c\/em\u003e\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eStep 3: Choose Your Configuration\u003c\/h2\u003e\n\n  \u003cdiv class=\"model-comparison\"\u003e\n    \u003cdiv class=\"model-card\"\u003e\n      \u003ch4\u003eRam-Micro-532\u003c\/h4\u003e\n      \u003cp class=\"best-for\"\u003eBest for: Research laboratories, materials science, geology\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003e532 nm excitation for maximum Raman signal strength\u003c\/li\u003e\n        \u003cli\u003eIdeal for inorganics, minerals, carbon materials, semiconductors\u003c\/li\u003e\n        \u003cli\u003eHigh sensitivity for weak Raman scatterers\u003c\/li\u003e\n        \u003cli\u003eFull spectral range: 200–4000 cm⁻¹\u003c\/li\u003e\n        \u003cli\u003eResearch-grade spectral resolution: 8–15 cm⁻¹\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"model-card\"\u003e\n      \u003ch4\u003eRam-Micro-785\u003c\/h4\u003e\n      \u003cp class=\"best-for\"\u003eBest for: General analytical labs, QC\/QA, chemical identification\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003e785 nm excitation for balanced performance\u003c\/li\u003e\n        \u003cli\u003eReduced fluorescence vs. 532 nm for organic samples\u003c\/li\u003e\n        \u003cli\u003eGood for polymers, chemicals, pharmaceuticals\u003c\/li\u003e\n        \u003cli\u003eVersatile for mixed sample types\u003c\/li\u003e\n        \u003cli\u003eStandard laboratory workhorse configuration\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"model-card\"\u003e\n      \u003ch4\u003eRam-Micro-1064\u003c\/h4\u003e\n      \u003cp class=\"best-for\"\u003eBest for: Forensics, biological samples, dark\/fluorescent materials\u003c\/p\u003e\n      \u003cul\u003e\n        \u003cli\u003e1064 nm excitation for ultimate fluorescence suppression\u003c\/li\u003e\n        \u003cli\u003eEssential for biological tissues, forensic samples\u003c\/li\u003e\n        \u003cli\u003eSafe for heat-sensitive and dark-colored materials\u003c\/li\u003e\n        \u003cli\u003eLower signal compensated by cooled detector\u003c\/li\u003e\n        \u003cli\u003eNon-destructive analysis of precious samples\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003ch2\u003eTechnical Considerations\u003c\/h2\u003e\n\n  \u003cdiv class=\"guide-section\"\u003e\n    \u003ch3\u003eSpectral Resolution vs. Sensitivity\u003c\/h3\u003e\n    \u003cp\u003eThe system provides 8–15 cm⁻¹ resolution, optimized for chemical identification and fingerprinting. For research requiring higher resolution (\u0026lt; 4 cm⁻¹), consider specialized research-grade systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"guide-section\"\u003e\n    \u003ch3\u003eSample Handling\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMicroscope integration:\u003c\/strong\u003e Working distance matched to objective focal length for precise focusing\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePower adjustment:\u003c\/strong\u003e 0–50 mW adjustable to prevent sample damage\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eArmored fiber probe:\u003c\/strong\u003e 1 m length for flexible sample positioning\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eNon-destructive:\u003c\/strong\u003e Preserves sample integrity for further analysis\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"guide-section\"\u003e\n    \u003ch3\u003eEnvironmental Requirements\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eLaboratory use:\u003c\/strong\u003e Standard 0–40°C operating range\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eField applications:\u003c\/strong\u003e Portable DC 12V\/5A power compatible\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eStorage:\u003c\/strong\u003e -10–55°C tolerance for transport\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"quick-guide\"\u003e\n    \u003ch3\u003eQuick Selection Guide\u003c\/h3\u003e\n    \u003col\u003e\n      \u003cli\u003e\n\u003cstrong\u003eAnalyzing minerals, carbon, semiconductors?\u003c\/strong\u003e → Choose Ram-Micro-532\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eGeneral chemical ID, polymers, pharmaceuticals?\u003c\/strong\u003e → Choose Ram-Micro-785\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eForensics, biological samples, dark materials?\u003c\/strong\u003e → Choose Ram-Micro-1064\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eUnknown sample types?\u003c\/strong\u003e → Start with 785 nm or contact us for method development\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eNeed field portability?\u003c\/strong\u003e → All configurations support 12V DC operation\u003c\/li\u003e\n    \u003c\/ol\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"recommendation-box\"\u003e\n    \u003cstrong\u003eNeed Help Deciding?\u003c\/strong\u003e Contact our applications team with your sample types and analysis requirements. We provide method development support and demonstration testing to ensure you select the optimal configuration.\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":47526840008923,"sku":"RamSitu","price":50000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/Raman_microscope.png?v=1759321343"},{"product_id":"open-path-teaching-raman-spectrometer-for-university-chemistry-materials-labs","title":"Open-Path Teaching Raman Spectrometer for University Chemistry \u0026 Materials Labs","description":"\u003cstyle\u003e\n  .raman-section {\n    max-width: 1200px;\n    margin: 0 auto;\n    padding: 40px 20px;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n    color: #1a1a1a;\n    background: #fff;\n  }\n  .raman-section h1 {\n    font-size: 42px;\n    font-weight: 700;\n    margin-bottom: 24px;\n    color: #000;\n    line-height: 1.2;\n  }\n  .raman-section .intro {\n    font-size: 18px;\n    line-height: 1.8;\n    margin-bottom: 16px;\n    color: #1a1a1a;\n  }\n  .raman-section .intro strong {\n    color: #000;\n    font-weight: 600;\n  }\n  .raman-section .secondary {\n    font-size: 16px;\n    line-height: 1.7;\n    margin-bottom: 32px;\n    color: #333;\n  }\n  .raman-section .highlights-box {\n    background: #f5f5f5;\n    border-left: 4px solid #000;\n    padding: 24px 28px;\n    margin: 32px 0;\n  }\n  .raman-section .highlights-box h3 {\n    font-size: 20px;\n    font-weight: 700;\n    margin: 0 0 16px 0;\n    color: #000;\n    padding-left: 0;\n  }\n  .raman-section .highlights-box h3::before {\n    display: none;\n  }\n  .raman-section .highlights-box ul {\n    margin: 0;\n    padding-left: 0;\n  }\n  .raman-section .highlights-box li {\n    margin-bottom: 8px;\n    line-height: 1.6;\n    color: #1a1a1a;\n    padding-left: 16px;\n    position: relative;\n  }\n  .raman-section .highlights-box li::before {\n    content: \"•\";\n    position: absolute;\n    left: 0;\n    color: #000;\n    font-weight: bold;\n  }\n  .raman-section h2 {\n    font-size: 28px;\n    font-weight: 700;\n    color: #000;\n    border-bottom: 3px solid #000;\n    padding-bottom: 12px;\n    margin: 48px 0 24px 0;\n  }\n  .raman-section h3 {\n    font-size: 20px;\n    font-weight: 700;\n    color: #000;\n    margin: 32px 0 16px 0;\n    position: relative;\n    padding-left: 20px;\n  }\n  .raman-section h3::before {\n    content: \"\";\n    position: absolute;\n    left: 0;\n    top: 50%;\n    transform: translateY(-50%);\n    width: 8px;\n    height: 8px;\n    background: #000;\n  }\n  .raman-section h4 {\n    font-size: 18px;\n    font-weight: 700;\n    margin: 24px 0 12px 0;\n    color: #000;\n  }\n  .raman-section ul {\n    margin: 0 0 24px 0;\n    padding-left: 0;\n    list-style: none;\n  }\n  .raman-section ul li {\n    margin-bottom: 10px;\n    padding-left: 16px;\n    position: relative;\n    line-height: 1.6;\n    color: #1a1a1a;\n  }\n  .raman-section ul li::before {\n    content: \"•\";\n    position: absolute;\n    left: 0;\n    color: #000;\n    font-weight: bold;\n  }\n  .raman-section ul li strong {\n    color: #000;\n    font-weight: 600;\n  }\n  .raman-section .table-wrap {\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    margin: 32px 0;\n  }\n  .raman-section .specs-table {\n    width: 100%;\n    min-width: 560px;\n    border-collapse: collapse;\n    box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n  }\n  .raman-section .specs-table th {\n    background: #1a1a1a;\n    color: #fff;\n    padding: 14px 16px;\n    text-align: left;\n    font-weight: 600;\n    border: 1px solid #1a1a1a;\n    white-space: nowrap;\n  }\n  .raman-section .specs-table td {\n    padding: 14px 16px;\n    border: 1px solid #ddd;\n    text-align: left;\n    color: #1a1a1a;\n    background: #fff;\n  }\n  .raman-section .specs-table tr:nth-child(even) td {\n    background: #fafafa;\n  }\n  .raman-section .model-card {\n    border: 1px solid #ddd;\n    padding: 20px;\n    margin-bottom: 15px;\n  }\n  .raman-section .model-card.recommended {\n    border: 2px solid #1a1a1a;\n    position: relative;\n  }\n  .raman-section .model-card .badge {\n    display: inline-block;\n    background: #000;\n    color: #fff;\n    padding: 2px 8px;\n    font-size: 12px;\n    font-weight: 600;\n    margin-left: 8px;\n    vertical-align: middle;\n  }\n  .raman-section .model-card .rec-badge {\n    position: absolute;\n    top: 0;\n    right: 0;\n    background: #1a1a1a;\n    color: #fff;\n    padding: 4px 10px;\n    font-size: 11px;\n    text-transform: uppercase;\n    font-weight: 600;\n  }\n  .raman-section .model-card h4 {\n    font-size: 16px;\n    font-weight: 700;\n    margin: 0 0 8px 0;\n    color: #000;\n  }\n  .raman-section .model-card p {\n    font-size: 14px;\n    color: #555;\n    line-height: 1.6;\n    margin: 0 0 12px 0;\n  }\n  .raman-section .model-card .price-tag {\n    font-size: 15px;\n    font-weight: 700;\n    color: #000;\n    margin-top: 8px;\n  }\n  .raman-section .model-card .price-list {\n    font-size: 13px;\n    color: #333;\n    margin-top: 6px;\n    line-height: 1.8;\n  }\n  .raman-section .model-grid {\n    display: grid;\n    grid-template-columns: 1fr 1fr;\n    gap: 40px;\n    margin-bottom: 40px;\n  }\n  .raman-section .tip-box {\n    background: #f5f5f5;\n    padding: 15px;\n    margin-top: 20px;\n    font-size: 13px;\n    color: #555;\n    line-height: 1.6;\n  }\n  @media (max-width: 768px) {\n    .raman-section {\n      padding: 24px 16px;\n    }\n    .raman-section h1 {\n      font-size: 26px;\n    }\n    .raman-section h2 {\n      font-size: 20px;\n      margin: 36px 0 18px 0;\n    }\n    .raman-section h3 {\n      font-size: 17px;\n    }\n    .raman-section .intro {\n      font-size: 15px;\n    }\n    .raman-section .model-grid {\n      grid-template-columns: 1fr;\n      gap: 24px;\n    }\n    .raman-section .highlights-box {\n      padding: 16px 18px;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"raman-section\"\u003e\n\u003ch1\u003eEduRaman Series\u003c\/h1\u003e\n\u003cp class=\"intro\"\u003e\u003cstrong\u003eOpen Optical-Path Design — See the Science.\u003c\/strong\u003e Traditional spectrometers hide the optical path inside a black box. The EduRaman series exposes the laser beam, gratings, and detector—allowing students to see exactly how Raman scattering works in real time.\u003c\/p\u003e\n\u003cp class=\"secondary\"\u003eDesigned for university chemistry and materials labs, the EduRaman platform combines research-grade sensitivity with an open, safety-engineered architecture. Whether teaching molecular vibration theory or characterizing carbon nanomaterials, EduRaman delivers clear, reliable data for students and instructors alike.\u003c\/p\u003e\n\u003cdiv class=\"highlights-box\"\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen optical-path design\u003c\/strong\u003e — Visible beam path demonstrates optical principles in real-time\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-modal capability\u003c\/strong\u003e — Raman, Fluorescence, Absorption, and Microscope in one platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety-engineered\u003c\/strong\u003e — Separated excitation and detection regions for safe classroom use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh sensitivity\u003c\/strong\u003e — Cooled detector (SNR \u0026gt;2000:1) for clear, reproducible student data2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSelect Model\u003c\/h2\u003e\n\u003cdiv class=\"model-grid\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"model-card\"\u003e\n\u003ch4\u003eEduRaman \u003cspan class=\"badge\"\u003eEntry-Level\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e532\/785 nm laser • 150–3900 cm⁻¹ • 10 cm⁻¹ resolution\u003cbr\u003eRaman + Microscope imaging\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"model-card recommended\"\u003e\n\u003cdiv class=\"rec-badge\"\u003eRecommended\u003c\/div\u003e\n\u003ch4\u003eEduRaman Pro \u003cspan class=\"badge\"\u003eAdvanced\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e532\/785 nm laser • 150–4000 cm⁻¹, 450–950 nm • 6 cm⁻¹ \/ 2 nm resolution\u003cbr\u003eAdjustable dual-grating (1200 + 150 g\/mm)\u003cbr\u003eRaman + Fluorescence + Absorption + Microscope\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tip-box\"\u003e\n\u003cstrong\u003eNeed help choosing?\u003c\/strong\u003e The Pro model adds fluorescence spectroscopy, visible absorption, and adjustable grating for advanced curriculum and research preparation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePhysical chemistry and molecular vibration theory\u003c\/li\u003e\n\u003cli\u003eGemstone identification (diamond, moissanite, CZ)\u003c\/li\u003e\n\u003cli\u003eForensic document and ink analysis\u003c\/li\u003e\n\u003cli\u003eCarbon nanomaterials characterization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"table-wrap\"\u003e\n\u003ctable class=\"specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eEduRaman\u003c\/th\u003e\n\u003cth\u003eEduRaman Pro\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRaman Spectroscopy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes (6 cm⁻¹)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMicroscope Imaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFluorescence Spectroscopy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eYes (2 nm resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVisible Absorption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eYes (450–950 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiffraction Grating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed 1200 g\/mm\u003c\/td\u003e\n\u003ctd\u003eAdjustable 1200\/150 g\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpectral Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150–3900 cm⁻¹\u003c\/td\u003e\n\u003ctd\u003e150–2400\/2400–4000 cm⁻¹, 450–950 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e532 nm or 785 nm\u003c\/td\u003e\n\u003ctd\u003e532 nm or 785 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCooled to -15°C, SNR \u0026gt;2000:1\u003c\/td\u003e\n\u003ctd\u003eCooled to -15°C, SNR \u0026gt;2000:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"EduRam-532A","offer_id":48296613380315,"sku":null,"price":23500.0,"currency_code":"USD","in_stock":true},{"title":"EduRam-532B","offer_id":48296615051483,"sku":null,"price":38000.0,"currency_code":"USD","in_stock":true},{"title":"EduRam-633A","offer_id":48508588261595,"sku":null,"price":45000.0,"currency_code":"USD","in_stock":true},{"title":"EduRam-633B","offer_id":48508588294363,"sku":null,"price":25000.0,"currency_code":"USD","in_stock":true},{"title":"EduRam-785A","offer_id":48508588327131,"sku":null,"price":25000.0,"currency_code":"USD","in_stock":true},{"title":"EduRam-785B","offer_id":48508588359899,"sku":null,"price":40000.0,"currency_code":"USD","in_stock":true},{"title":"EduRam Pro-532A","offer_id":48508588392667,"sku":null,"price":31500.0,"currency_code":"USD","in_stock":true},{"title":"EduRam Pro-633A","offer_id":48508588425435,"sku":null,"price":39000.0,"currency_code":"USD","in_stock":true},{"title":"EduRam Pro-785A","offer_id":48508588458203,"sku":null,"price":34500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/Edu-Raman_f1717980-e6a0-42fe-a816-e587e06412d1.png?v=1776323787"},{"product_id":"in-situ-raman-microscope-for-battery-2d-materials-electrochemical-research","title":"In-Situ Raman Microscope for Battery, 2D Materials \u0026 Electrochemical Research","description":"\u003cstyle\u003e\n  .raman-guide {\n    max-width: 1200px;\n    margin: 0 auto;\n    padding: 40px 20px;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n    color: #1a1a1a;\n    background: #fff;\n    box-sizing: border-box;\n  }\n  .raman-guide * { box-sizing: border-box; }\n\n  .raman-guide h1 {\n    font-size: 36px;\n    font-weight: 700;\n    margin: 0 0 16px 0;\n    color: #000;\n    line-height: 1.2;\n    word-wrap: break-word;\n  }\n  .raman-guide .subtitle {\n    font-size: 18px;\n    color: #555;\n    margin: 0 0 32px 0;\n    line-height: 1.6;\n    word-wrap: break-word;\n  }\n\n  .raman-guide .hero-box {\n    background: #f7f7f7;\n    color: #1a1a1a;\n    padding: 32px;\n    margin: 32px 0;\n    border: 2px solid #1a1a1a;\n  }\n  .raman-guide .hero-box h2 {\n    font-size: 24px;\n    margin: 0 0 16px 0;\n    font-weight: 700;\n    color: #000;\n    line-height: 1.3;\n  }\n  .raman-guide .hero-box p {\n    font-size: 16px;\n    line-height: 1.7;\n    margin: 0;\n    color: #333;\n  }\n\n  .raman-guide .exclusive-banner {\n    background: #fff;\n    border: 3px solid #000;\n    padding: 24px 32px;\n    margin: 32px 0;\n    text-align: center;\n  }\n  .raman-guide .exclusive-banner h2 {\n    font-size: 22px;\n    font-weight: 700;\n    color: #000;\n    margin: 0 0 12px 0;\n    border: none;\n    padding: 0;\n    line-height: 1.3;\n  }\n  .raman-guide .exclusive-banner p {\n    font-size: 16px;\n    color: #333;\n    margin: 0;\n    line-height: 1.6;\n  }\n  .raman-guide .exclusive-banner strong { color: #000; font-weight: 700; }\n\n  .raman-guide .comparison-section { margin: 40px 0; }\n  .raman-guide .comparison-section \u003e h2 {\n    font-size: 24px;\n    font-weight: 700;\n    color: #000;\n    border-bottom: 3px solid #000;\n    padding-bottom: 12px;\n    margin: 0 0 24px 0;\n    line-height: 1.3;\n  }\n  .raman-guide .comparison-scroll {\n    width: 100%;\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n  }\n  .raman-guide .comparison-table {\n    width: 100%;\n    min-width: 560px;\n    border-collapse: collapse;\n    font-size: 15px;\n  }\n  .raman-guide .comparison-table thead tr {\n    background: #f0f0f0;\n    color: #000;\n  }\n  .raman-guide .comparison-table thead th {\n    padding: 14px 18px;\n    text-align: left;\n    font-weight: 700;\n    font-size: 14px;\n    letter-spacing: 0.3px;\n    border-bottom: 2px solid #000;\n  }\n  .raman-guide .comparison-table thead th:first-child { width: 28%; }\n  .raman-guide .comparison-table thead th.col-ramsitu {\n    background: #e8e8e8;\n    color: #000;\n    border-left: 3px solid #000;\n  }\n  .raman-guide .comparison-table thead th.col-conventional {\n    background: #f0f0f0;\n    color: #555;\n  }\n  .raman-guide .comparison-table tbody tr { border-bottom: 1px solid #ddd; }\n  .raman-guide .comparison-table tbody tr:nth-child(even) { background: #fafafa; }\n  .raman-guide .comparison-table tbody tr:hover { background: #f5f5f5; }\n  .raman-guide .comparison-table td {\n    padding: 14px 18px;\n    vertical-align: top;\n    line-height: 1.5;\n    word-wrap: break-word;\n  }\n  .raman-guide .comparison-table td:first-child {\n    font-weight: 700;\n    color: #000;\n    font-size: 13px;\n    text-transform: uppercase;\n    letter-spacing: 0.3px;\n  }\n  .raman-guide .comparison-table td.win { color: #000; font-weight: 600; }\n  .raman-guide .comparison-table td.win::before { content: \"✓ \"; font-weight: 700; color: #1a7a1a; }\n  .raman-guide .comparison-table td.lose { color: #888; }\n  .raman-guide .comparison-table td.lose::before { content: \"✗ \"; color: #bbb; }\n  .raman-guide .comparison-note {\n    font-size: 13px;\n    color: #666;\n    margin: 12px 0 0 0;\n    font-style: italic;\n    line-height: 1.5;\n  }\n\n  .raman-guide .core-params {\n    background: #f7f7f7;\n    color: #1a1a1a;\n    padding: 32px;\n    margin: 32px 0;\n    border: 2px solid #1a1a1a;\n  }\n  .raman-guide .core-params h3 {\n    color: #000;\n    margin: 0 0 24px 0;\n    padding: 0;\n    font-size: 22px;\n    font-weight: 700;\n    border: none;\n    line-height: 1.3;\n  }\n  .raman-guide .core-params-grid {\n    display: grid;\n    grid-template-columns: repeat(2, 1fr);\n    gap: 20px;\n  }\n  .raman-guide .core-param-item {\n    padding: 16px 0;\n    border-bottom: 1px solid #ccc;\n    min-width: 0;\n  }\n  .raman-guide .core-param-label {\n    font-size: 12px;\n    color: #666;\n    text-transform: uppercase;\n    letter-spacing: 0.5px;\n    margin: 0 0 8px 0;\n    font-weight: 600;\n    line-height: 1.4;\n    word-wrap: break-word;\n  }\n  .raman-guide .core-param-value {\n    font-size: 16px;\n    font-weight: 600;\n    color: #000;\n    line-height: 1.5;\n    word-wrap: break-word;\n    overflow-wrap: break-word;\n  }\n\n  .raman-guide h2 {\n    font-size: 24px;\n    font-weight: 700;\n    color: #000;\n    border-bottom: 3px solid #000;\n    padding-bottom: 12px;\n    margin: 40px 0 24px 0;\n    line-height: 1.3;\n  }\n\n  .raman-guide .app-grid {\n    display: grid;\n    grid-template-columns: repeat(3, 1fr);\n    gap: 20px;\n    margin: 24px 0;\n  }\n  .raman-guide .app-card {\n    border: 2px solid #000;\n    padding: 24px;\n    background: #fff;\n    transition: background 0.2s;\n    min-width: 0;\n  }\n  .raman-guide .app-card:hover { background: #f5f5f5; }\n  .raman-guide .app-card h3 {\n    margin: 0 0 12px 0;\n    font-size: 17px;\n    font-weight: 700;\n    color: #000;\n    line-height: 1.3;\n  }\n  .raman-guide .app-card p {\n    margin: 0;\n    font-size: 14px;\n    line-height: 1.6;\n    color: #333;\n    word-wrap: break-word;\n  }\n  .raman-guide .app-card .tag {\n    display: inline-block;\n    background: #f0f0f0;\n    color: #000;\n    border: 1px solid #ccc;\n    padding: 4px 10px;\n    font-size: 12px;\n    font-weight: 600;\n    margin-top: 12px;\n    letter-spacing: 0.3px;\n  }\n\n  .raman-guide .feature-list {\n    margin: 24px 0;\n    padding: 0;\n    list-style: none;\n  }\n  .raman-guide .feature-list li {\n    padding: 16px 0 16px 28px;\n    border-bottom: 1px solid #ddd;\n    font-size: 16px;\n    line-height: 1.6;\n    position: relative;\n    word-wrap: break-word;\n  }\n  .raman-guide .feature-list li:before {\n    content: \"→\";\n    position: absolute;\n    left: 0;\n    top: 16px;\n    color: #000;\n    font-weight: 700;\n    font-size: 16px;\n  }\n  .raman-guide .feature-list li strong { color: #000; font-weight: 700; }\n\n  .raman-guide .cta-box {\n    background: #f5f5f5;\n    border-left: 4px solid #000;\n    padding: 32px;\n    margin: 40px 0;\n    text-align: center;\n  }\n  .raman-guide .cta-box h3 {\n    font-size: 22px;\n    margin: 0 0 12px 0;\n    color: #000;\n    font-weight: 700;\n    line-height: 1.3;\n  }\n  .raman-guide .cta-box p {\n    font-size: 16px;\n    color: #555;\n    margin: 0 0 20px 0;\n    line-height: 1.6;\n    word-wrap: break-word;\n  }\n  .raman-guide .cta-button {\n    display: inline-block;\n    background: #1a1a1a;\n    color: #fff;\n    padding: 14px 32px;\n    font-size: 16px;\n    font-weight: 600;\n    text-decoration: none;\n    border: 2px solid #1a1a1a;\n    transition: all 0.2s;\n    cursor: pointer;\n    line-height: 1.4;\n  }\n  .raman-guide .cta-button:hover { background: #fff; color: #1a1a1a; }\n\n  .raman-guide .config-note {\n    background: #fafafa;\n    padding: 20px;\n    margin: 24px 0;\n    border: 1px solid #ddd;\n  }\n  .raman-guide .config-note h4 {\n    margin: 0 0 8px 0;\n    font-size: 16px;\n    font-weight: 700;\n    color: #000;\n    line-height: 1.3;\n  }\n  .raman-guide .config-note p {\n    margin: 0;\n    font-size: 14px;\n    color: #555;\n    line-height: 1.5;\n    word-wrap: break-word;\n  }\n\n  @media (max-width: 900px) {\n    .raman-guide .app-grid { grid-template-columns: repeat(2, 1fr); }\n  }\n  @media (max-width: 768px) {\n    .raman-guide { padding: 24px 16px; }\n    .raman-guide h1 { font-size: 26px; }\n    .raman-guide .subtitle { font-size: 15px; }\n    .raman-guide .hero-box { padding: 20px; margin: 20px 0; }\n    .raman-guide .hero-box h2 { font-size: 19px; }\n    .raman-guide .hero-box p { font-size: 14px; }\n    .raman-guide .exclusive-banner { padding: 18px; margin: 20px 0; }\n    .raman-guide .exclusive-banner h2 { font-size: 17px; }\n    .raman-guide .exclusive-banner p { font-size: 14px; }\n    .raman-guide .comparison-table { font-size: 13px; }\n    .raman-guide .comparison-table thead th,\n    .raman-guide .comparison-table td { padding: 10px 12px; }\n    .raman-guide .core-params { padding: 20px; margin: 20px 0; }\n    .raman-guide .core-params h3 { font-size: 18px; margin-bottom: 16px; }\n    .raman-guide .core-params-grid { grid-template-columns: 1fr; gap: 12px; }\n    .raman-guide .core-param-item { padding: 10px 0; }\n    .raman-guide .core-param-label { font-size: 11px; }\n    .raman-guide .core-param-value { font-size: 14px; }\n    .raman-guide h2 { font-size: 19px; margin: 28px 0 16px 0; }\n    .raman-guide .app-grid { grid-template-columns: 1fr; gap: 14px; }\n    .raman-guide .app-card { padding: 18px; }\n    .raman-guide .app-card h3 { font-size: 16px; }\n    .raman-guide .app-card p { font-size: 13px; }\n    .raman-guide .feature-list li { font-size: 14px; padding-left: 22px; }\n    .raman-guide .cta-box { padding: 20px; margin: 28px 0; }\n    .raman-guide .cta-box h3 { font-size: 18px; }\n    .raman-guide .cta-button { padding: 12px 20px; font-size: 14px; display: block; max-width: 280px; margin: 0 auto; }\n  }\n  @media (max-width: 480px) {\n    .raman-guide { padding: 16px 12px; }\n    .raman-guide h1 { font-size: 22px; }\n    .raman-guide .exclusive-banner { padding: 14px; }\n    .raman-guide .exclusive-banner h2 { font-size: 15px; }\n    .raman-guide .comparison-table thead th,\n    .raman-guide .comparison-table td { padding: 8px 10px; font-size: 12px; }\n    .raman-guide .core-param-value { font-size: 13px; }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"raman-guide\"\u003e\n\u003ch1\u003eRamSitu Series\u003c\/h1\u003e\n\u003cp class=\"subtitle\"\u003eIn-Situ EC-Raman Microscope for Advanced Materials \u0026amp; Energy Research\u003c\/p\u003e\n\u003cdiv class=\"hero-box\"\u003e\n\u003ch2\u003eResearch-Grade Raman. Compact Design.\u003c\/h2\u003e\n\u003cp\u003eBreak through the limitations of bulky, expensive traditional Raman systems. RamSitu delivers high-sensitivity spectroscopy with optional electrochemical integration and intelligent automation — all in a footprint that fits your glove box or crowded lab bench.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"exclusive-banner\"\u003e\n\u003ch2\u003eWorld’s First Fully Integrated In-Situ Electrochemical Raman Microscope\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSame spot. Same time. Three signals.\u003c\/strong\u003e RamSitu is the first commercial instrument to simultaneously capture electrode morphology, Raman spectra, and electrochemical activity from the exact same location — in a single factory-aligned system. No separate modules. No custom cells. No alignment drift.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"comparison-section\"\u003e\n\u003ch2\u003eRamSitu vs. Conventional Coupled Systems\u003c\/h2\u003e\n\u003cdiv class=\"comparison-scroll\"\u003e\n\u003ctable class=\"comparison-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCapability\u003c\/th\u003e\n\u003cth class=\"col-ramsitu\"\u003eRamSitu (Integrated)\u003c\/th\u003e\n\u003cth class=\"col-conventional\"\u003eConventional Setup\u003cbr\u003e\u003csmall style=\"font-weight: 400; font-size: 12px;\"\u003eRaman + Potentiostat + Custom Cell\u003c\/small\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd class=\"win\"\u003eSingle factory-aligned instrument. Plug in and measure.\u003c\/td\u003e\n\u003ctd class=\"lose\"\u003e3+ separate instruments from different vendors. Manual coupling required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpatial Correlation\u003c\/td\u003e\n\u003ctd class=\"win\"\u003eExact same spot: optical, Raman, and electrochemical signals co-registered by design.\u003c\/td\u003e\n\u003ctd class=\"lose\"\u003eSpatial drift between probes. Correlation uncertainty in published data.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup \u0026amp; Alignment Time\u003c\/td\u003e\n\u003ctd class=\"win\"\u003eSame-day operation. Factory-aligned optics. No user calibration needed.\u003c\/td\u003e\n\u003ctd class=\"lose\"\u003eWeeks to months of custom cell design, alignment, and validation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlove Box Compatibility\u003c\/td\u003e\n\u003ctd class=\"win\"\u003eCompact all-in-one design fits standard glove boxes (Ar, N₂ atmosphere).\u003c\/td\u003e\n\u003ctd class=\"lose\"\u003eBulky coupled systems cannot fit inside glove boxes. Air-sensitive samples at risk.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrochemical Control\u003c\/td\u003e\n\u003ctd class=\"win\"\u003eBuilt-in potentiostat: ±10 V, ±250 mA. Synchronized with spectral acquisition.\u003c\/td\u003e\n\u003ctd class=\"lose\"\u003eExternal potentiostat with manual trigger synchronization. Timing errors common.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation\u003c\/td\u003e\n\u003ctd class=\"win\"\u003eAI-driven particle recognition and auto-positioning (\u0026lt;2 μm). Unattended runs.\u003c\/td\u003e\n\u003ctd class=\"lose\"\u003eManual particle search and positioning. Operator-dependent throughput.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVendor Support\u003c\/td\u003e\n\u003ctd class=\"win\"\u003eSingle point of contact for hardware, software, and applications support.\u003c\/td\u003e\n\u003ctd class=\"lose\"\u003eMultiple vendors. Integration issues fall between support teams.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cost of Ownership\u003c\/td\u003e\n\u003ctd class=\"win\"\u003eOne system. One service contract. No custom cell fabrication costs.\u003c\/td\u003e\n\u003ctd class=\"lose\"\u003eCumulative cost of 3+ instruments, custom cells, and integration engineering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublication Readiness\u003c\/td\u003e\n\u003ctd class=\"win\"\u003eSimultaneous tri-modal data from a single certified instrument. Reproducible by design.\u003c\/td\u003e\n\u003ctd class=\"lose\"\u003eMulti-instrument data requires extensive cross-validation and methodology justification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"comparison-note\"\u003e* Comparison based on typical configurations of separate benchtop Raman microscopes, standalone potentiostats, and custom spectroelectrochemical cells as reported in literature. Contact us for a detailed technical comparison specific to your current setup.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"core-params\"\u003e\n\u003ch3\u003eCore Parameters\u003c\/h3\u003e\n\u003cdiv class=\"core-params-grid\"\u003e\n\u003cdiv class=\"core-param-item\"\u003e\n\u003cdiv class=\"core-param-label\"\u003eLaser Wavelength\u003c\/div\u003e\n\u003cdiv class=\"core-param-value\"\u003e532 nm \/ 633 nm \/ 785 nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"core-param-item\"\u003e\n\u003cdiv class=\"core-param-label\"\u003eSpectral Resolution\u003c\/div\u003e\n\u003cdiv class=\"core-param-value\"\u003e≤4 cm⁻¹ \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"core-param-item\"\u003e\n\u003cdiv class=\"core-param-label\"\u003eSpectral Range\u003c\/div\u003e\n\u003cdiv class=\"core-param-value\"\u003e170–3900 cm⁻¹ (532 nm) \/ 170–3900 cm⁻¹ (633 nm) \/ 170–3400 cm⁻¹ (785 nm)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"core-param-item\"\u003e\n\u003cdiv class=\"core-param-label\"\u003eLaser Power\u003c\/div\u003e\n\u003cdiv class=\"core-param-value\"\u003e532 nm: ≥100 mW  |  633 nm: ≥30 mW  |  785 nm: ≥100 mW\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"core-param-item\"\u003e\n\u003cdiv class=\"core-param-label\"\u003eSpectral Accuracy\u003c\/div\u003e\n\u003cdiv class=\"core-param-value\"\u003e±3 cm⁻¹\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"core-param-item\"\u003e\n\u003cdiv class=\"core-param-label\"\u003eInstrument SNR\u003c\/div\u003e\n\u003cdiv class=\"core-param-value\"\u003e\u0026gt;5000:1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"core-param-item\"\u003e\n\u003cdiv class=\"core-param-label\"\u003eElectrochemical Workstation\u003c\/div\u003e\n\u003cdiv class=\"core-param-value\"\u003eVoltage: ±10 V  |  Current: ±250 mA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"core-param-item\"\u003e\n\u003cdiv class=\"core-param-label\"\u003eParticle Localization\u003c\/div\u003e\n\u003cdiv class=\"core-param-value\"\u003eAuto-positioning accuracy \u0026lt;2 μm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhich Research Challenge Are You Solving?\u003c\/h2\u003e\n\u003cdiv class=\"app-grid\"\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch3\u003e2D \u0026amp; Novel Materials\u003c\/h3\u003e\n\u003cp\u003eCharacterize graphene, MoS₂, and layered materials with micron-scale precision. Map spatial distribution and uniformity for quality control and publication-ready data.\u003c\/p\u003e\n\u003cspan class=\"tag\"\u003eMaterials Science\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch3\u003eBattery \u0026amp; Energy Storage\u003c\/h3\u003e\n\u003cp\u003eMonitor SEI formation, electrolyte decomposition, and electrode interfaces in real-time during charge\/discharge cycles. Understand failure mechanisms at the molecular level.\u003c\/p\u003e\n\u003cspan class=\"tag\"\u003eEnergy Research\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch3\u003eCatalysis \u0026amp; Electrochemistry\u003c\/h3\u003e\n\u003cp\u003eTrack reaction pathways and surface intermediates with synchronized electrochemical-Raman measurements. Ideal for mechanistic studies and catalyst optimization.\u003c\/p\u003e\n\u003cspan class=\"tag\"\u003eChemistry\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch3\u003eMicrobial \u0026amp; Single-Cell Analysis\u003c\/h3\u003e\n\u003cp\u003eAutomated particle recognition eliminates manual searching. High-throughput screening of bacteria and cells for microbiome research and clinical applications.\u003c\/p\u003e\n\u003cspan class=\"tag\"\u003eLife Sciences\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch3\u003ePharmaceutical Polymorphs\u003c\/h3\u003e\n\u003cp\u003eRapidly identify crystal forms and polymorph screening for drug development. Ensure batch consistency and regulatory compliance.\u003c\/p\u003e\n\u003cspan class=\"tag\"\u003ePharma QA\/QC\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"app-card\"\u003e\n\u003ch3\u003eTeaching \u0026amp; Core Facilities\u003c\/h3\u003e\n\u003cp\u003eProfessional-grade capabilities at accessible pricing. Perfect for university labs and multi-user facilities requiring reliability without complexity.\u003c\/p\u003e\n\u003cspan class=\"tag\"\u003eEducation\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eWhy RamSitu Fits Your Workflow\u003c\/h2\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Integrated Design:\u003c\/strong\u003e Unlike conventional setups requiring separate Raman microscopes, external potentiostats, and custom cells with months of alignment work, RamSitu arrives as one factory-aligned system. Start collecting synchronized data the same day.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame-Spot Simultaneity:\u003c\/strong\u003e Optical microscopy, Raman spectroscopy, and electrochemical probes target the exact same electrode location. No spatial drift. No correlation uncertainty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlove Box Compatible:\u003c\/strong\u003e Compact all-in-one design operates seamlessly in controlled atmosphere environments (Ar, N₂) for air-sensitive samples — impossible with bulky coupled systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Automation:\u003c\/strong\u003e AI-driven particle recognition and auto-positioning for unattended high-throughput screening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Laser Flexibility:\u003c\/strong\u003e Configure 532 nm, 633 nm, or 785 nm excitation to match your sample fluorescence and resonance requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"config-note\"\u003e\n\u003ch4\u003eFlexible Configuration\u003c\/h4\u003e\n\u003cp\u003eRamSitu is modular by design. Start with the base Raman microscope and add electrochemical capabilities or automated particle analysis as your research evolves. Contact our applications team to configure the optimal setup for your specific samples and measurement goals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cta-box\"\u003e\n\u003ch3\u003eDiscuss Your Application Requirements\u003c\/h3\u003e\n\u003cp\u003eOur technical team will recommend the optimal laser configuration, sampling accessories, and software package for your research. Full specifications and pricing provided upon consultation.\u003c\/p\u003e\n\u003ca class=\"cta-button\" href=\"\/en-cn\/pages\/contact\"\u003eRequest Technical Consultation\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48304176300251,"sku":"RamSitu1","price":40000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/RamSitu_image.png?v=1782014315"},{"product_id":"confocal-raman-microscope","title":"Confocal Raman Microscope Ram-M330\/M350 | 532\/633\/785nm, \u003c0.9cm⁻¹","description":"\u003c!-- NWSPEC Confocal Raman Microscope Product Guide - Shopify Code --\u003e\n\u003cdiv style=\"font-family: Arial, sans-serif; color: #000; max-width: 900px; margin: 0 auto; padding: 20px; background: #fff;\" class=\"nwspec-product-guide\"\u003e\n\u003c!-- Header Section --\u003e\n\u003cdiv style=\"border-bottom: 2px solid #000; padding-bottom: 15px; margin-bottom: 25px;\"\u003e\n\u003ch1 style=\"font-size: 28px; font-weight: bold; margin: 0 0 8px 0; color: #000;\"\u003eConfocal Raman Microscope\u003c\/h1\u003e\n\u003cp style=\"font-size: 16px; margin: 0; color: #333;\"\u003eRam-M330 \/ Ram-M350 Series\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Product Introduction --\u003e\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: bold; border-left: 4px solid #000; padding-left: 10px; margin-bottom: 15px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; font-size: 14px; color: #000;\"\u003eHigh-sensitivity automated confocal Raman microscope with compact footprint (28.3\"W x 31.9\"D x 21.8\"H). Supports up to three configurable excitation wavelengths (532\/633\/785nm) for simultaneous Raman and photoluminescence analysis. Spectral resolution better than 0.9 cm-1 (M350) with silicon third-order Raman peak SNR exceeding 30:1. Fully automated operation with optional sample loading integration for unattended workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Key Highlights --\u003e\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: bold; border-left: 4px solid #000; padding-left: 10px; margin-bottom: 15px;\"\u003eKey Highlights\u003c\/h2\u003e\n\u003cdiv style=\"line-height: 1.8; font-size: 14px;\"\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eHigh Degree of Automation:\u003c\/strong\u003e Automatic wavelength switching, automatic mode transition between imaging and Raman, integration with automated sampling systems for unattended operation\u003c\/p\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eExcellent Performance:\u003c\/strong\u003e Spectral resolution better than 0.9 cm-1, high sensitivity (Si third-order Raman peak SNR \u0026gt;30), submicron high-resolution Raman imaging (0.5um lateral resolution)\u003c\/p\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e All-in-one integrated optical system, motorized switching for three excitation wavelengths, upright research-grade reflected bright-field microscope\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Model Selection Guide --\u003e\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: bold; border-left: 4px solid #000; padding-left: 10px; margin-bottom: 15px;\"\u003eModel Selection Guide\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; text-align: left; border: 1px solid #000;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: center; border: 1px solid #000;\"\u003eRam-M330\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: center; border: 1px solid #000;\"\u003eRam-M350\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; font-weight: bold;\"\u003eFocal Length\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center;\"\u003e330 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center;\"\u003e350 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; font-weight: bold;\"\u003eSpectral Resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center;\"\u003eBetter than 2 cm-1\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center;\"\u003eBetter than 0.9 cm-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; font-weight: bold;\"\u003eBest For\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center;\"\u003eStandard Raman analysis, quality control\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center;\"\u003eHigh-resolution research, advanced materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- WAVELENGTH CONFIGURATION ORDER GUIDE --\u003e\n\u003cdiv style=\"margin: 25px 0; padding: 20px; border: 2px solid #000; background: #fff;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: bold; margin: 0 0 15px 0; border-bottom: 2px solid #000; padding-bottom: 8px;\"\u003eWavelength Configuration Order Guide\u003c\/h2\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.5; margin-bottom: 15px;\"\u003eSystem supports up to three excitation wavelengths (532\/633\/785nm) with fully motorized, software-controlled switching. \u003cstrong\u003eSelect any combination:\u003c\/strong\u003e single wavelength, any two wavelengths, or all three wavelengths.\u003c\/p\u003e\n\u003ch3 style=\"font-size: 14px; font-weight: bold; margin: 15px 0 10px 0;\"\u003eHow to Configure Your System\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 8px; text-align: left; border: 1px solid #000; width: 22%;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: left; border: 1px solid #000; width: 35%;\"\u003eSelect Any Combination\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: left; border: 1px solid #000; width: 43%;\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; font-weight: bold;\"\u003eSingle Wavelength\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eChoose 1 from: 532nm, 633nm, or 785nm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eDedicated applications with known sample types, budget-conscious setups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; font-weight: bold;\"\u003eDual Wavelength\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eChoose any 2: 532+633nm, 532+785nm, or 633+785nm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eMixed sample workflows, flexibility for both inorganics and organics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; font-weight: bold;\"\u003eTriple Wavelength\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eAll 3 wavelengths: 532+633+785nm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eMaximum versatility, multi-user facilities, research environments with diverse samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-size: 14px; font-weight: bold; margin: 15px 0 10px 0;\"\u003eWavelength Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12px; margin-bottom: 20px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 8px; text-align: left; border: 1px solid #000; width: 14%;\"\u003eWavelength\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: center; border: 1px solid #000; width: 12%;\"\u003ePower\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: left; border: 1px solid #000; width: 34%;\"\u003ePrimary Applications\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: left; border: 1px solid #000; width: 40%;\"\u003eSelection Guidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; font-weight: bold;\"\u003e532 nm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center;\"\u003e100 mW\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eCarbon nanotubes, graphene, SERS, semiconductors, inorganics\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eHighest sensitivity. Best for carbon materials and inorganics. Avoid for highly fluorescent samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; font-weight: bold;\"\u003e633 nm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center;\"\u003e35 mW\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eForensics, fibers, minerals, corrosion studies, general unknowns\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eBalanced performance. Good fluorescence suppression vs 532nm. Ideal for forensic and mineral analysis.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; font-weight: bold;\"\u003e785 nm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center;\"\u003e100 mW\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003ePharmaceuticals, biological tissue, proteins, oils, dyes, polymers\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eBest fluorescence suppression. Industry standard for organic applications. Safest choice for unknowns.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"font-size: 14px; font-weight: bold; margin: 15px 0 10px 0;\"\u003eWhich Configuration Do I Need?\u003c\/h3\u003e\n\u003cdiv style=\"line-height: 1.8; font-size: 13px; margin-bottom: 15px;\"\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eSingle:\u003c\/strong\u003e One sample type only (e.g., carbon materials to 532nm; pharmaceuticals to 785nm)\u003c\/p\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eDual:\u003c\/strong\u003e Two sample categories (e.g., 532+785nm for inorganics + organics)\u003c\/p\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eTriple:\u003c\/strong\u003e Multi-user facility or service lab requiring maximum flexibility\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 style=\"font-size: 14px; font-weight: bold; margin: 15px 0 10px 0;\"\u003eRecommended Pairings by Application\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 8px; text-align: left; border: 1px solid #000;\"\u003eApplication Field\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: center; border: 1px solid #000;\"\u003eRecommended Config\u003c\/th\u003e\n\u003cth style=\"padding: 8px; text-align: left; border: 1px solid #000;\"\u003eRationale\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eCarbon\/Nanomaterials Research\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center; font-weight: bold;\"\u003e532 nm only\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003e532nm provides highest sensitivity for carbon structures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003ePharmaceutical QC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center; font-weight: bold;\"\u003e785 nm only\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003e785nm eliminates fluorescence from most APIs; industry standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eMaterials Science (Mixed)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center; font-weight: bold;\"\u003e532+785 nm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003e532nm for inorganics\/carbon, 785nm for organics\/polymers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eForensics\/Security\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center; font-weight: bold;\"\u003e633+785 nm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003e633nm for fibers\/minerals, 785nm for explosives\/drugs\/inks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eAcademic Teaching\/Research\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center; font-weight: bold;\"\u003eTriple (532+633+785)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eMaximum flexibility; compare wavelength effects on same sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eContract\/Service Laboratory\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000; text-align: center; font-weight: bold;\"\u003eTriple (532+633+785)\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #000;\"\u003eHandle any customer sample without limitations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"margin-top: 15px; padding: 10px; background: #f5f5f5; border-left: 3px solid #000; font-size: 12px; line-height: 1.5;\"\u003e\n\u003cstrong\u003eTechnical Note:\u003c\/strong\u003e All configurations feature TEM00 lasers with software-adjustable power, narrow-band filters, and RazorEdge filters. Fully motorized automatic switching with no manual alignment required. Field-upgradable from single to dual\/triple.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- OPTIONAL CONFIGURATIONS --\u003e\n\u003cdiv style=\"margin: 25px 0; padding: 20px; border: 2px solid #000; background: #fff;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: bold; margin: 0 0 15px 0; border-bottom: 2px solid #000; padding-bottom: 8px;\"\u003eOptional Configurations\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #000; color: #fff;\"\u003e\n\u003cth style=\"padding: 10px; text-align: left; border: 1px solid #000; width: 35%;\"\u003eOption\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left; border: 1px solid #000; width: 65%;\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #000; font-weight: bold;\"\u003eAuto-Focus Module\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #000;\"\u003eImage-based auto-focus for uneven surfaces and long-duration mapping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f5f5f5;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #000; font-weight: bold;\"\u003eParticle Auto-Positioning Algorithm\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #000;\"\u003eAutomatic particle recognition and laser positioning for API\/microplastic analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- Additional Configuration Options --\u003e\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: bold; border-left: 4px solid #000; padding-left: 10px; margin-bottom: 15px;\"\u003eAdditional Configuration Options\u003c\/h2\u003e\n\u003cdiv style=\"line-height: 1.8; font-size: 14px;\"\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eObjectives:\u003c\/strong\u003e 10x (NA 0.3), 50x (NA 0.5), 100x (NA 0.9) - 4-position motorized turret\u003c\/p\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eGratings:\u003c\/strong\u003e 150\/600\/1800 g\/mm with software-controlled automatic switching\u003c\/p\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eAutomation Package:\u003c\/strong\u003e Standard motorized XYZ stage (75x50x50mm, 0.05um step) or Full automation with sample loading integration\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Applications --\u003e\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: bold; border-left: 4px solid #000; padding-left: 10px; margin-bottom: 15px;\"\u003eApplication Fields\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: 1fr 1fr; gap: 10px; font-size: 13px; line-height: 1.6;\"\u003e\n\u003cdiv\u003eMaterials Analysis\u003c\/div\u003e\n\u003cdiv\u003eEnvironmental Monitoring\u003c\/div\u003e\n\u003cdiv\u003ePharmaceutical Testing\u003c\/div\u003e\n\u003cdiv\u003eBattery Research\u003c\/div\u003e\n\u003cdiv\u003eMedical Identification\u003c\/div\u003e\n\u003cdiv\u003eGemstone Identification\u003c\/div\u003e\n\u003cdiv\u003eCultural Heritage Analysis\u003c\/div\u003e\n\u003cdiv\u003eLife Sciences\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Performance Verification --\u003e\n\u003cdiv style=\"margin-bottom: 30px;\"\u003e\n\u003ch2 style=\"font-size: 18px; font-weight: bold; border-left: 4px solid #000; padding-left: 10px; margin-bottom: 15px;\"\u003eVerified Performance\u003c\/h2\u003e\n\u003cdiv style=\"line-height: 1.8; font-size: 14px;\"\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eSpectral Resolution:\u003c\/strong\u003e 585nm neon lamp test: 0.797 cm-1 half peak width (M350)\u003c\/p\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eSensitivity:\u003c\/strong\u003e Silicon third-order Raman peak SNR \u0026gt;30:1 (7100 counts signal \/ 214 counts noise)\u003c\/p\u003e\n\u003cp style=\"margin: 5px 0;\"\u003e\u003cstrong\u003eSpatial Resolution:\u003c\/strong\u003e Two-dimensional materials mapping: ~0.5um lateral resolution verified\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Contact Section --\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Ram-M330-532 (S)","offer_id":48583839908059,"sku":"Ram-M-7","price":168000.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M330-633 (S)","offer_id":48583839940827,"sku":"Ram-M-8","price":168000.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M330-785 (S)","offer_id":48583839973595,"sku":"Ram-M-9","price":168000.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M330-532+633 (D)","offer_id":48583840006363,"sku":"Ram-M-10","price":193200.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M330-532+785 (D)","offer_id":48583840039131,"sku":"Ram-M-11","price":193200.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M330-633+785 (D)","offer_id":48583840071899,"sku":"Ram-M-12","price":193200.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M330-532+633+785 (T)","offer_id":48583840104667,"sku":"Ram-M-13","price":219800.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M350-532 (S)","offer_id":48583851442395,"sku":"Ram-M-14","price":203000.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M350-633 (S)","offer_id":48583851475163,"sku":"Ram-M-15","price":203000.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M350-785 (S)","offer_id":48583851507931,"sku":"Ram-M-16","price":203000.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M350-532+633 (D)","offer_id":48583851540699,"sku":"Ram-M-17","price":228200.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M350-532+785 (D)","offer_id":48583851573467,"sku":"Ram-M-18","price":228200.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M350-633+785 (D)","offer_id":48583851606235,"sku":"Ram-M-19","price":228200.0,"currency_code":"USD","in_stock":true},{"title":"Ram-M350-532+633+785 (T)","offer_id":48583851639003,"sku":"Ram-M-20","price":254000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/Ram-M350.png?v=1777459999"}],"url":"https:\/\/nwspec.com\/en-cn\/collections\/raman-spectrometer.oembed","provider":"NWSPEC","version":"1.0","type":"link"}