{"product_id":"fully-automated-solid-phase-extraction-system","title":"Fully Automated Solid Phase Extraction System (PrepS Series)","description":"\u003cdiv style=\"font-family: Arial, sans-serif; color: #333; line-height: 1.7; max-width: 800px; margin: 0 auto; padding: 0 20px;\"\u003e\n\u003c!-- HEADER --\u003e\n\u003cdiv style=\"border-bottom: 3px solid #000; padding: 40px 0 20px; margin-bottom: 40px;\"\u003e\n\u003ch1 style=\"font-size: 32px; font-weight: 800; color: #000; margin: 0 0 12px; line-height: 1.2;\"\u003eFully Automated SPE System — PrepS Series\u003c\/h1\u003e\n\u003cp style=\"font-size: 16px; color: #555; margin: 0;\"\u003eAutomated conditioning, sample loading, washing, blow-drying, and elution with independent multichannel control.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- 3 HIGHLIGHTS --\u003e\n\u003cdiv style=\"display: flex; gap: 20px; margin-bottom: 50px; flex-wrap: wrap;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e2 \/ 4 \/ 6 \/ 8\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eIndependent channels by model\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e20–80\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eExtraction columns per batch\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e20 L\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eMaximum sample volume with optional module\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- WHY AUTOMATE --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 20px;\"\u003eWhy Automate Your SPE Workflow\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 12px; color: #555;\"\u003eManual solid phase extraction requires repetitive conditioning, sample loading, washing, drying, elution, and collection. Every manual step adds variability and occupies skilled laboratory personnel.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 20px; color: #555;\"\u003eThe PrepS Series automates the complete SPE workflow while providing independent channel operation, editable method parameters, and an enclosed transparent chamber for process observation.\u003c\/p\u003e\n\u003cdiv style=\"background: #f5f5f5; border-left: 4px solid #000; padding: 16px 20px; margin-bottom: 50px;\"\u003e\n\u003cstrong style=\"color: #000; display: block; margin-bottom: 8px;\"\u003eWith full automation:\u003c\/strong\u003e\n\u003cp style=\"margin: 0; color: #444;\"\u003eLoad cartridges and samples, select the method, and start the run. The system completes conditioning, loading, washing, blow-drying, elution, and collection with walkaway unattended operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- 6 STEPS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eWhat the System Does\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eCondition\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eAutomated SPE cartridge conditioning with editable method parameters.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eLoad\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eSmall-sample loading is standard. The optional large-volume loading module supports sample volumes up to 20 L.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eWash\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eProgrammable washing with eight reagent channels. The anti-backflow flow path helps prevent reflux and supports stable pressure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eBlow-Dry\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eAutomated nitrogen blow-drying with editable pressure and time settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eElute and Concentrate\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eAutomated elution and automatic quantitative concentration at 1, 3, 6, 10, 12, or 20 mL.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e6\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eCollect\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eModel-specific collection racks support 10–50 mL tubes on PrepS 2 \/ 4 \/ 6 and 10–35 mL tubes on PrepS 8.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- MODEL COMPARISON --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 12px;\"\u003ePrepS Model Comparison\u003c\/h2\u003e\n\u003cp style=\"font-size: 13px; color: #777; margin: 0 0 12px;\"\u003eOn smaller screens, swipe horizontally to compare models.\u003c\/p\u003e\n\u003cdiv role=\"region\" aria-label=\"PrepS technical specification table\" tabindex=\"0\" style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 12px;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 760px; border-collapse: collapse; font-size: 14px; line-height: 1.45;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5; border-top: 2px solid #000; border-bottom: 2px solid #000;\"\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 28%;\"\u003eTechnical parameter\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 18%;\"\u003ePrepS 2\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 18%;\"\u003ePrepS 4\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 18%;\"\u003ePrepS 6\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 18%;\"\u003ePrepS 8\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eNumber of channels\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e4\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e6\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eMaximum extraction columns\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e20\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e40\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e60\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eMaximum sample volume\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e20 L\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e20 L\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e20 L\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e20 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eAutomatic quantitative concentration\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e1 \/ 3 \/ 6 \/ 10 \/ 12 \/ 20 mL\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e1 \/ 3 \/ 6 \/ 10 \/ 12 \/ 20 mL\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e1 \/ 3 \/ 6 \/ 10 \/ 12 \/ 20 mL\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e1 \/ 3 \/ 6 \/ 10 \/ 12 \/ 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eCollection tube volume\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e10–50 mL\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e10–50 mL\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e10–50 mL\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e10–35 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eLarge-volume module\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported (optional module)\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported (optional module)\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported (optional module)\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported (optional module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eImmunoaffinity column\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eString module \/ membrane extraction\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eNot listed\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eNot listed\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eReagent channels\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e8\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eTouchscreen\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAngle adjustable\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAngle adjustable\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAngle adjustable\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAngle adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eMaximum inlet pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e0.7 MPa (100 psi)\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e0.7 MPa (100 psi)\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e0.7 MPa (100 psi)\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e0.7 MPa (100 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eOverall power\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e100 W\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e120 W\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e130 W\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e140 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eGas supply\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eHigh-purity nitrogen \/ inert gas\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eHigh-purity nitrogen \/ inert gas\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eHigh-purity nitrogen \/ inert gas\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eHigh-purity nitrogen \/ inert gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAmbient to 40 °C, 20–80% RH\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAmbient to 40 °C, 20–80% RH\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAmbient to 40 °C, 20–80% RH\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eAmbient to 40 °C, 20–80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eNoise\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e50 dB\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e50 dB\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e50 dB\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e473 × 600 × 731 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e593 × 600 × 731 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e773 × 600 × 731 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e773 × 600 × 731 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eMachine weight\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e~72 kg\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e~90 kg\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e~110 kg\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003e~115 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eFlow path\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003ePTFE standard; PEEK\/metal optional\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003ePTFE standard; PEEK\/metal optional\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003ePTFE standard; PEEK\/metal optional\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003ePTFE standard; PEEK\/metal optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 2px solid #000;\"\u003e\n\u003ctd style=\"padding: 11px 10px; font-weight: bold; color: #000;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eCE\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eCE\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eCE\u003c\/td\u003e\n\u003ctd style=\"padding: 11px 10px; color: #555;\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size: 13px; color: #777; margin: 0 0 50px;\"\u003eLarge-volume loading (up to 20 L) is supported on every model as an optional module. String-column and membrane-extraction options apply to PrepS 6 and PrepS 8.\u003c\/p\u003e\n\n\u003c!-- ORDER GUIDE --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eOrder Guide\u003c\/h2\u003e\n\u003ch3 style=\"font-size: 17px; font-weight: bold; color: #000; margin: 0 0 12px;\"\u003e1. Select Model and Extraction Format\u003c\/h3\u003e\n\u003cdiv role=\"region\" aria-label=\"PrepS model and extraction format ordering table\" tabindex=\"0\" style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin-bottom: 36px;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 780px; border-collapse: collapse; font-size: 14px; line-height: 1.45;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5; border-top: 2px solid #000; border-bottom: 2px solid #000;\"\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 14%;\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 28%;\"\u003eCollection rack options\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 28%;\"\u003eCartridge \/ piston configuration\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 30%;\"\u003eAdvanced extraction options\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 10px; color: #000; font-weight: bold;\"\u003ePrepS 2\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e16 × 125 mm tube rack; 50 mL quantitative concentration-tube rack\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e1, 3, 6, 10, 12, or 20 mL SPE column rack with cartridge-specific piston assembly\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003eNot listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 10px; color: #000; font-weight: bold;\"\u003ePrepS 4\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e16 × 125 mm tube rack; 50 mL quantitative concentration-tube rack\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e1, 3, 6, 10, 12, or 20 mL SPE column rack with cartridge-specific piston assembly\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003eNot listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 10px; color: #000; font-weight: bold;\"\u003ePrepS 6\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e16 × 125 mm tube rack; 50 mL quantitative concentration-tube rack\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e1, 3, 6, 10, 12, or 20 mL SPE column rack with cartridge-specific piston assembly\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003eString-column racks; 47 mm membrane or membrane-and-column modules; universal collection rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 2px solid #000;\"\u003e\n\u003ctd style=\"padding: 12px 10px; color: #000; font-weight: bold;\"\u003ePrepS 8\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e16 × 125 mm or 20 × 150 mm tube racks\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e1, 3, 6, 10, 12, or 20 mL SPE column rack with cartridge-specific piston assembly\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003eString-column racks; 47 mm membrane or membrane-and-column modules; universal collection rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"font-size: 17px; font-weight: bold; color: #000; margin: 0 0 12px;\"\u003e2. Select Consumables and Method Accessories\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 36px; font-size: 14px; line-height: 1.45;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f5f5f5; border-top: 2px solid #000; border-bottom: 2px solid #000;\"\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold; width: 38%;\"\u003eConsumable group\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"padding: 12px 10px; text-align: left; color: #000; font-weight: bold;\"\u003eAvailable formats\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 10px; color: #000; font-weight: bold;\"\u003eSPE cartridges\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003eC18 and HLB; 1, 3, 6, 10, 12, or 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 10px; color: #000; font-weight: bold;\"\u003eCollection tubes\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e16 × 75, 16 × 100, 16 × 125, or 20 × 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 10px; color: #000; font-weight: bold;\"\u003eQuantitative concentration tube\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e50 mL with 0.5 \/ 1.0 mL tail tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 10px; color: #000; font-weight: bold;\"\u003ePrepS 6 \/ PrepS 8 string-column racks\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e1, 3, 6, 10, or 12 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 2px solid #000;\"\u003e\n\u003ctd style=\"padding: 12px 10px; color: #000; font-weight: bold;\"\u003ePrepS 6 \/ PrepS 8 membrane format\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 10px; color: #555;\"\u003e47 mm membrane extraction; combined membrane-and-column extraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"font-size: 17px; font-weight: bold; color: #000; margin: 0 0 12px;\"\u003e3. Complete the Operating System\u003c\/h3\u003e\n\u003cp style=\"margin: 0 0 50px; color: #555; border-top: 1px solid #ddd; padding-top: 14px; font-size: 14px;\"\u003eModel-specific main unit and operation software; waste-solvent filtration and small-sample loading modules; SPE column rack and cartridge-specific piston assemblies; collection rack and height block; optional large-sample loading module for volumes up to 20 L; high-purity nitrogen or other suitable inert gas supply; one-year host warranty.\u003c\/p\u003e\n\n\u003c!-- RECOMMENDED STARTING POINTS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eRecommended Starting Points\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px 32px; margin-bottom: 40px;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 240px; border-top: 2px solid #000; padding-top: 12px;\"\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eCompact Routine SPE — PrepS 2\u003c\/strong\u003e\n\u003cp style=\"margin: 6px 0 0; color: #555; font-size: 14px;\"\u003eTwo channels and up to 20 columns per batch. Select cartridge rack, piston assemblies, and collection racks required by the method.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 240px; border-top: 2px solid #000; padding-top: 12px;\"\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eGeneral-Purpose Laboratory — PrepS 4\u003c\/strong\u003e\n\u003cp style=\"margin: 6px 0 0; color: #555; font-size: 14px;\"\u003eFour channels and up to 40 columns per batch. Use 16 × 125 mm collection tubes or 50 mL quantitative concentration tubes; add large-volume loading when needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 240px; border-top: 2px solid #000; padding-top: 12px;\"\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eMulti-Method Laboratory — PrepS 6\u003c\/strong\u003e\n\u003cp style=\"margin: 6px 0 0; color: #555; font-size: 14px;\"\u003eSix channels and up to 60 columns per batch, with string-column and 47 mm membrane-extraction options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 240px; border-top: 2px solid #000; padding-top: 12px;\"\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eHighest Channel Count — PrepS 8\u003c\/strong\u003e\n\u003cp style=\"margin: 6px 0 0; color: #555; font-size: 14px;\"\u003eEight channels and up to 80 columns per batch. Confirm the 10–35 mL collection range and select 16 × 125 mm or 20 × 150 mm tube racks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- TYPICAL APPLICATIONS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 20px;\"\u003eTypical Applications\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdiv style=\"padding: 14px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eWater and Environmental Samples\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eAutomated SPE extraction, cleanup, and concentration workflows for surface, ground, and drinking water testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 14px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eFood and Beverage\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003ePesticide residue, veterinary drug, and contaminant cleanup with application-matched cartridge formats.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 14px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eBiological and Clinical Samples\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eSerum, plasma, and urine sample preparation with independent multichannel processing to prevent cross-contamination.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 14px 0;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eSoil and Pharmaceutical Analysis\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eFlexible cartridge, membrane, and collection formats for trace target enrichment and matrix removal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- COMPLIANCE AND SYSTEM FEATURES --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 20px;\"\u003eCompliance and System Features\u003c\/h2\u003e\n\u003cul style=\"margin: 0 0 50px; padding-left: 20px; color: #555; font-size: 14px; line-height: 2;\"\u003e\n\u003cli\u003eCE certified for laboratory equipment compliance\u003c\/li\u003e\n\u003cli\u003eTransparent automatic door and enclosed chamber for real-time process observation\u003c\/li\u003e\n\u003cli\u003eIndependent multichannel sampling, needle cleaning, and collection to prevent cross-contamination\u003c\/li\u003e\n\u003cli\u003eAnti-backflow flow path design to help prevent reflux and maintain stable pressure\u003c\/li\u003e\n\u003cli\u003eEditable extraction parameters and eight reagent channels\u003c\/li\u003e\n\u003cli\u003ePTFE flow path as standard, with PEEK or metal optional\u003c\/li\u003e\n\u003cli\u003eImmunoaffinity column support across all PrepS models\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- COMMON QUESTIONS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eCommon Questions\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdetails open=\"\" style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eWhich SPE cartridges and formats are available? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e-\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eThe ordering range lists C18 and HLB cartridges in 1, 3, 6, 10, 12, and 20 mL formats. Select the SPE column rack and cartridge-specific piston assembly to match your laboratory method.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eCan I run large-volume water samples? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. Large-volume loading is supported on every PrepS model as an optional module, handling sample volumes up to 20 L.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eWhat extraction modes are supported? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eStandard SPE cartridge extraction is available across the entire series. PrepS 6 and PrepS 8 additionally support string-column extraction, 47 mm membrane extraction, and combined membrane-and-column extraction.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eHow many extraction columns can be processed per batch? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003ePrepS 2, PrepS 4, PrepS 6, and PrepS 8 support maximum batch capacities of 20, 40, 60, and 80 extraction columns respectively. Daily throughput depends on your specific method run time.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eCan PrepS be combined with other NWSPEC systems? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. PrepS pairs seamlessly with NWSPEC PrepN automated nitrogen evaporators or PrepV parallel vacuum evaporators for complete sample extraction, cleanup, and concentration.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eAre immunoaffinity columns supported? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. Immunoaffinity column support is standard on PrepS 2, PrepS 4, PrepS 6, and PrepS 8. Select the matching column rack and accessories during configuration.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003c!-- FOOTER NOTE --\u003e\n\u003cdiv style=\"border-top: 2px solid #000; padding: 30px 0 40px; text-align: center;\"\u003e\n\u003cp style=\"font-size: 16px; font-weight: bold; color: #000; margin: 0 0 8px;\"\u003eCustom method development and application consulting available.\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; color: #888; margin: 0;\"\u003eCompatible with LC-MS\/MS and GC-MS\/MS analytical platforms\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":49125238603995,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/Fully_Automated_Solid_Phase_Extraction_System.png?v=1794390146","url":"https:\/\/nwspec.com\/en-cn\/products\/fully-automated-solid-phase-extraction-system","provider":"NWSPEC","version":"1.0","type":"link"}