{"product_id":"rm-10-f-hyperspectral-fluorescence-microscope","title":"Hyperspectral Fluorescence Microscope","description":"\u003cstyle\u003e\n.hfm-wrap {\n  font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n  background: #ffffff;\n  color: #1a1a1a;\n  font-size: 16px;\n  line-height: 1.65;\n  box-sizing: border-box;\n}\n.hfm-wrap * {\n  box-sizing: border-box;\n  margin: 0;\n  padding: 0;\n}\n.hfm-inner {\n  max-width: 920px;\n  margin: 0 auto;\n  padding: 0 20px;\n}\n@media (min-width: 768px) {\n  .hfm-inner {\n    padding: 0 32px;\n  }\n}\n\n\/* Header *\/\n.hfm-header {\n  padding: 36px 0 28px;\n  border-bottom: 2px solid #111827;\n  margin-bottom: 32px;\n}\n.hfm-badge {\n  display: inline-block;\n  border: 1px solid #d1d5db;\n  border-radius: 4px;\n  padding: 4px 12px;\n  font-size: 12px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 1.5px;\n  color: #4b5563;\n  margin-bottom: 12px;\n}\n.hfm-header h2 {\n  font-size: clamp(26px, 4vw, 38px);\n  font-weight: 800;\n  color: #111827;\n  letter-spacing: -0.5px;\n  margin-bottom: 8px;\n}\n.hfm-header-sub {\n  font-size: 17px;\n  font-weight: 600;\n  color: #4b5563;\n  margin-bottom: 12px;\n}\n.hfm-header p {\n  font-size: 15px;\n  color: #4b5563;\n  max-width: 780px;\n  line-height: 1.65;\n}\n\n\/* Metrics Row: 2 cols on mobile, 3 on tablet, 6 on desktop *\/\n.hfm-stats {\n  margin-top: 28px;\n  display: grid;\n  grid-template-columns: repeat(2, 1fr);\n  gap: 12px;\n}\n@media (min-width: 600px) {\n  .hfm-stats {\n    grid-template-columns: repeat(3, 1fr);\n  }\n}\n@media (min-width: 900px) {\n  .hfm-stats {\n    grid-template-columns: repeat(6, 1fr);\n  }\n}\n.hfm-stat {\n  background: #f9fafb;\n  border: 1px solid #e5e5e5;\n  border-radius: 6px;\n  padding: 16px 10px;\n  text-align: center;\n}\n.hfm-stat-val {\n  font-size: 22px;\n  font-weight: 800;\n  color: #111827;\n}\n.hfm-stat-lbl {\n  font-size: 11px;\n  font-weight: 700;\n  color: #6b7280;\n  text-transform: uppercase;\n  letter-spacing: 0.5px;\n  margin-top: 4px;\n}\n\n\/* Sections *\/\n.hfm-section {\n  margin-bottom: 44px;\n}\n.hfm-title {\n  font-size: 20px;\n  font-weight: 800;\n  color: #111827;\n  display: flex;\n  align-items: center;\n  gap: 12px;\n  margin-bottom: 6px;\n}\n.hfm-num {\n  width: 32px;\n  height: 32px;\n  border-radius: 50%;\n  background: #111827;\n  color: #ffffff;\n  display: inline-flex;\n  align-items: center;\n  justify-content: center;\n  font-size: 14px;\n  font-weight: 700;\n  flex-shrink: 0;\n}\n.hfm-subtitle {\n  font-size: 14px;\n  color: #6b7280;\n  margin-bottom: 20px;\n  padding-left: 44px;\n}\n@media (max-width: 480px) {\n  .hfm-subtitle {\n    padding-left: 0;\n  }\n}\n\n\/* 2-Column Responsive Card Grid *\/\n.hfm-cards-2 {\n  display: grid;\n  grid-template-columns: 1fr;\n  gap: 16px;\n}\n@media (min-width: 640px) {\n  .hfm-cards-2 {\n    grid-template-columns: repeat(2, 1fr);\n  }\n}\n\n\/* Application Scenario Cards *\/\n.hfm-card {\n  border: 1px solid #e5e5e5;\n  border-radius: 8px;\n  padding: 22px;\n  background: #ffffff;\n  display: flex;\n  flex-direction: column;\n  justify-content: space-between;\n}\n.hfm-card-tag {\n  display: inline-block;\n  align-self: flex-start;\n  font-size: 11px;\n  font-weight: 700;\n  text-transform: uppercase;\n  letter-spacing: 1px;\n  padding: 3px 8px;\n  border-radius: 4px;\n  background: #f3f4f6;\n  color: #374151;\n  margin-bottom: 10px;\n}\n.hfm-card-title {\n  font-size: 16px;\n  font-weight: 700;\n  color: #111827;\n  margin-bottom: 8px;\n}\n.hfm-card-desc {\n  font-size: 14px;\n  color: #4b5563;\n  line-height: 1.6;\n  margin-bottom: 14px;\n}\n.hfm-card-specs {\n  border-top: 1px solid #f3f4f6;\n  padding-top: 12px;\n  font-size: 13px;\n  color: #6b7280;\n  line-height: 1.5;\n}\n.hfm-card-specs strong {\n  color: #111827;\n}\n\n\/* Responsive Table *\/\n.hfm-table-wrap {\n  overflow-x: auto;\n  -webkit-overflow-scrolling: touch;\n  margin: 16px 0;\n  border: 1px solid #e5e5e5;\n  border-radius: 8px;\n}\n.hfm-table {\n  width: 100%;\n  border-collapse: collapse;\n  font-size: 14px;\n  min-width: 580px;\n}\n.hfm-table th {\n  background: #f9fafb;\n  color: #111827;\n  font-weight: 700;\n  font-size: 13px;\n  text-transform: uppercase;\n  letter-spacing: 0.5px;\n  padding: 12px 16px;\n  text-align: left;\n  border-bottom: 1px solid #e5e5e5;\n}\n.hfm-table td {\n  padding: 12px 16px;\n  border-bottom: 1px solid #f3f4f6;\n  vertical-align: top;\n}\n.hfm-table tr:last-child td {\n  border-bottom: none;\n}\n.hfm-table td:first-child {\n  font-weight: 600;\n  color: #111827;\n}\n\n\/* FAQ Block *\/\n.hfm-faq-item {\n  border: 1px solid #e5e5e5;\n  border-radius: 6px;\n  padding: 16px 20px;\n  margin-bottom: 12px;\n  background: #ffffff;\n}\n.hfm-faq-q {\n  font-size: 15px;\n  font-weight: 700;\n  color: #111827;\n  margin-bottom: 6px;\n}\n.hfm-faq-a {\n  font-size: 14px;\n  color: #4b5563;\n  line-height: 1.6;\n}\n\n\/* Note Box *\/\n.hfm-note {\n  background: #f9fafb;\n  border-left: 3px solid #111827;\n  border-radius: 0 6px 6px 0;\n  padding: 14px 18px;\n  margin: 16px 0;\n  font-size: 14px;\n  color: #4b5563;\n  line-height: 1.55;\n}\n.hfm-note strong {\n  color: #111827;\n}\n\n\/* CTA Box *\/\n.hfm-cta {\n  background: #f9fafb;\n  border: 1px solid #e5e5e5;\n  border-radius: 8px;\n  padding: 32px 24px;\n  text-align: center;\n  margin-top: 36px;\n}\n.hfm-cta h3 {\n  font-size: 20px;\n  font-weight: 800;\n  color: #111827;\n  margin-bottom: 8px;\n}\n.hfm-cta p {\n  font-size: 15px;\n  color: #4b5563;\n  max-width: 620px;\n  margin: 0 auto 20px;\n  line-height: 1.6;\n}\n.hfm-cta-btn {\n  display: inline-block;\n  padding: 12px 32px;\n  background: #111827;\n  color: #ffffff !important;\n  font-size: 14px;\n  font-weight: 700;\n  text-decoration: none;\n  border-radius: 6px;\n  letter-spacing: 0.5px;\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"hfm-wrap\"\u003e\n  \u003cdiv class=\"hfm-inner\"\u003e\n    \u003c!-- Header Block --\u003e\n    \u003cdiv class=\"hfm-header\"\u003e\n      \u003cdiv class=\"hfm-badge\"\u003eRM-10-F Series — Hyperspectral Fluorescence Imaging\u003c\/div\u003e\n      \u003ch2\u003eRM-10-F Hyperspectral Fluorescence Microscope\u003c\/h2\u003e\n      \u003cp class=\"hfm-header-sub\"\u003eHigh-Speed Spectral Unmixing \u0026amp; Quantitative Multi-Target Phenotyping\u003c\/p\u003e\n      \u003cp\u003e\n        The RM-10-F Series integrates a full 400–1000 nm transmission-grating imaging spectrometer with research-grade\n        fluorescence microscopy. Every pixel acquires its complete optical spectrum at \u0026lt;2.3 nm resolution, eliminating\n        emission filter limits and crosstalk while removing tissue autofluorescence quantitatively.\n      \u003c\/p\u003e\n\n      \u003c!-- Key Performance Metrics (Strictly 2 cols on mobile, 3 on tablet, 6 on desktop) --\u003e\n      \u003cdiv class=\"hfm-stats\" role=\"list\"\u003e\n        \u003cdiv class=\"hfm-stat\" role=\"listitem\"\u003e\n          \u003cdiv class=\"hfm-stat-val\"\u003e400–1000 nm\u003c\/div\u003e\n          \u003cdiv class=\"hfm-stat-lbl\"\u003eSpectral Range\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"hfm-stat\" role=\"listitem\"\u003e\n          \u003cdiv class=\"hfm-stat-val\"\u003e\u0026lt;2.3 nm\u003c\/div\u003e\n          \u003cdiv class=\"hfm-stat-lbl\"\u003eResolution (F\/2.4)\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"hfm-stat\" role=\"listitem\"\u003e\n          \u003cdiv class=\"hfm-stat-val\"\u003e≥300\u003c\/div\u003e\n          \u003cdiv class=\"hfm-stat-lbl\"\u003eSpectral Bands\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"hfm-stat\" role=\"listitem\"\u003e\n          \u003cdiv class=\"hfm-stat-val\"\u003e72 fps\u003c\/div\u003e\n          \u003cdiv class=\"hfm-stat-lbl\"\u003eFull-Spectrum Rate\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"hfm-stat\" role=\"listitem\"\u003e\n          \u003cdiv class=\"hfm-stat-val\"\u003e\u0026lt;1 μm\u003c\/div\u003e\n          \u003cdiv class=\"hfm-stat-lbl\"\u003eSpatial Resolution\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"hfm-stat\" role=\"listitem\"\u003e\n          \u003cdiv class=\"hfm-stat-val\"\u003e16-bit\u003c\/div\u003e\n          \u003cdiv class=\"hfm-stat-lbl\"\u003esCMOS Dynamic Range\u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Section 1: Core Application Scenarios --\u003e\n    \u003cdiv class=\"hfm-section\"\u003e\n      \u003cdiv class=\"hfm-title\"\u003e\n        \u003cspan class=\"hfm-num\"\u003e1\u003c\/span\u003e\n        \u003cspan\u003eKey Application Scenarios\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cp class=\"hfm-subtitle\"\u003eDesigned to resolve severe spectral overlap and autofluorescence challenges\u003c\/p\u003e\n\n      \u003cdiv class=\"hfm-cards-2\"\u003e\n        \u003cdiv class=\"hfm-card\"\u003e\n          \u003cspan class=\"hfm-card-tag\"\u003eImmuno-Oncology \u0026amp; Pathology\u003c\/span\u003e\n          \u003cdiv class=\"hfm-card-title\"\u003eMultiplexed Tumor Microenvironment Phenotyping\u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-desc\"\u003e\n            Simultaneously detect and quantify 7+ fluorescent markers on a single formalin-fixed tissue section.\n            Mathematical spectral unmixing separates emission spectra with overlapping peaks, enabling detailed spatial\n            profiling of immune checkpoints, T-cells, and tumor margins.\n          \u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-specs\"\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eKey Capability:\u003c\/strong\u003e Crosstalk-free 7+ channel unmixing\u003c\/div\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eRecommended Setup:\u003c\/strong\u003e RM-10-FX Automated System with Plan-Apochromat Optics\u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hfm-card\"\u003e\n          \u003cspan class=\"hfm-card-tag\"\u003eHistology \u0026amp; Biopsy\u003c\/span\u003e\n          \u003cdiv class=\"hfm-card-title\"\u003eTissue Autofluorescence Elimination \u0026amp; Margin Analysis\u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-desc\"\u003e\n            Endogenous collagen, elastin, and fixation artifacts produce strong broadband background autofluorescence that\n            obscures weak fluorophores. The RM-10-F isolates and subtracts autofluorescence signatures pixel by pixel,\n            delivering high signal-to-noise detection of low-expression targets.\n          \u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-specs\"\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eKey Capability:\u003c\/strong\u003e Quantitative background subtraction\u003c\/div\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eRecommended Setup:\u003c\/strong\u003e RM-10-FM or RM-10-FX with TE-Cooled sCMOS Core\u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hfm-card\"\u003e\n          \u003cspan class=\"hfm-card-tag\"\u003eCell Biology\u003c\/span\u003e\n          \u003cdiv class=\"hfm-card-title\"\u003eMulti-Target Fluorescent Protein \u0026amp; Organelle Co-Localization\u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-desc\"\u003e\n            Differentiate overlapping fluorescent proteins (e.g., GFP, YFP, CFP, and mCherry) and quantum dots in live or\n            fixed cell cultures. Full spectral recording allows retrospective reconstruction of arbitrary virtual emission\n            channels without re-staining or re-imaging.\n          \u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-specs\"\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eKey Capability:\u003c\/strong\u003e Post-acquisition virtual channel reconstruction\u003c\/div\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eRecommended Setup:\u003c\/strong\u003e RM-10-FM Upright Biological Microscope\u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hfm-card\"\u003e\n          \u003cspan class=\"hfm-card-tag\"\u003eHigh-Throughput Screening\u003c\/span\u003e\n          \u003cdiv class=\"hfm-card-title\"\u003eAutomated Whole-Slide Scanning \u0026amp; Drug Discovery\u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-desc\"\u003e\n            Equipped with a 120-slide automated sample chamber, intelligent autofocus, and motorized channel switching,\n            the system delivers high-throughput continuous screening for drug safety, target binding, and multi-marker\n            tissue microarrays (TMA).\n          \u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-specs\"\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eKey Capability:\u003c\/strong\u003e 120-slide smart chamber \u0026amp; unattended auto-focus\u003c\/div\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eRecommended Setup:\u003c\/strong\u003e RM-10-FX with Assist Cameras \u0026amp; Automated Stage\u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hfm-card\"\u003e\n          \u003cspan class=\"hfm-card-tag\"\u003eMaterials \u0026amp; Nanotechnology\u003c\/span\u003e\n          \u003cdiv class=\"hfm-card-title\"\u003eQuantum Dots, Metasurfaces \u0026amp; Microplastics\u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-desc\"\u003e\n            Analyze spatial spectral shifts in luminescent nanomaterials, carbon dots, 2D semiconductors, and microplastic\n            particulates. Sub-micron spatial resolution paired with \u0026lt;2.3 nm spectral precision tracks local surface\n            plasmon resonance (LSPR) and nanoscale emission shifts.\n          \u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-specs\"\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eKey Capability:\u003c\/strong\u003e Sub-micron spatial \u0026amp; 300+ band spectral mapping\u003c\/div\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eRecommended Setup:\u003c\/strong\u003e RM-10-FM \/ FX with High-Magnification Objectives\u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv class=\"hfm-card\"\u003e\n          \u003cspan class=\"hfm-card-tag\"\u003eForensic Science\u003c\/span\u003e\n          \u003cdiv class=\"hfm-card-title\"\u003eForensic Document Examination \u0026amp; Trace Evidence\u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-desc\"\u003e\n            Non-destructive identification of questioned documents, altered inks, and trace biological fluids on fluorescent\n            or patterned textiles. High-resolution continuous hyperspectral cubes distinguish identical-color inks via\n            subtle spectral reflectance and fluorescence differences.\n          \u003c\/div\u003e\n          \u003cdiv class=\"hfm-card-specs\"\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eKey Capability:\u003c\/strong\u003e Non-destructive chemical contrast discrimination\u003c\/div\u003e\n            \u003cdiv\u003e\n\u003cstrong\u003eRecommended Setup:\u003c\/strong\u003e RM-10-FM with Flexible Manual Stage\u003c\/div\u003e\n          \u003c\/div\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Section 2: Configuration Selection --\u003e\n    \u003cdiv class=\"hfm-section\"\u003e\n      \u003cdiv class=\"hfm-title\"\u003e\n        \u003cspan class=\"hfm-num\"\u003e2\u003c\/span\u003e\n        \u003cspan\u003eSelect System Configuration\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cp class=\"hfm-subtitle\"\u003eChoose between flexible manual research and unattended high-throughput automation\u003c\/p\u003e\n\n      \u003cdiv class=\"hfm-table-wrap\"\u003e\n        \u003ctable class=\"hfm-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth style=\"width: 25%;\"\u003eConfiguration\u003c\/th\u003e\n              \u003cth style=\"width: 18%;\"\u003eModel SKU\u003c\/th\u003e\n              \u003cth style=\"width: 32%;\"\u003eHardware Specifications\u003c\/th\u003e\n              \u003cth style=\"width: 25%;\"\u003eBest For\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eStandard Research Configuration\u003c\/td\u003e\n              \u003ctd\u003eRM-10-FM\u003c\/td\u003e\n              \u003ctd\u003eUpright biological microscope, manual focus, 118 × 76 mm stage with 4-slide holder, 7-channel manual fluorescence switching\u003c\/td\u003e\n              \u003ctd\u003eResearch labs, core facilities, routine multi-target cell and tissue imaging\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eAutomated High-Throughput Configuration\u003c\/td\u003e\n              \u003ctd\u003eRM-10-FX\u003c\/td\u003e\n              \u003ctd\u003eResearch-grade optics, intelligent autofocus, 120-slide smart sample chamber, motorized channel switching, dual RGB + grayscale assist cameras\u003c\/td\u003e\n              \u003ctd\u003eHigh-throughput pathology, tissue microarrays (TMA), clinical trials, and drug screening\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Section 3: Optics \u0026 Objective Options --\u003e\n    \u003cdiv class=\"hfm-section\"\u003e\n      \u003cdiv class=\"hfm-title\"\u003e\n        \u003cspan class=\"hfm-num\"\u003e3\u003c\/span\u003e\n        \u003cspan\u003eSelect Objective Set \u0026amp; Optical Package\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cp class=\"hfm-subtitle\"\u003eResearch-grade infinity-corrected optics engineered for chromatic accuracy\u003c\/p\u003e\n\n      \u003cdiv class=\"hfm-table-wrap\"\u003e\n        \u003ctable class=\"hfm-table\"\u003e\n          \u003cthead\u003e\n            \u003ctr\u003e\n              \u003cth style=\"width: 30%;\"\u003eOptics Package\u003c\/th\u003e\n              \u003cth style=\"width: 45%;\"\u003eIncluded Objectives \u0026amp; Specifications\u003c\/th\u003e\n              \u003cth style=\"width: 25%;\"\u003eSystem Match\u003c\/th\u003e\n            \u003c\/tr\u003e\n          \u003c\/thead\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd\u003ePlan-Achromatic Set\u003c\/td\u003e\n              \u003ctd\u003e4×, 10×, 20×, 40×, 50×; field number F.N 23, 25, or 26.5; \u0026lt;1 μm spatial resolution\u003c\/td\u003e\n              \u003ctd\u003eRM-10-FM (Standard)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003ePlan-Apochromatic Set\u003c\/td\u003e\n              \u003ctd\u003e4×, 10×, 20×, 40×, 60×; field number F.N 25 or 26.5; superior chromatic aberration correction across 400–1000 nm\u003c\/td\u003e\n              \u003ctd\u003eRM-10-FX (Automated)\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Section 4: Technical Specifications Summary --\u003e\n    \u003cdiv class=\"hfm-section\"\u003e\n      \u003cdiv class=\"hfm-title\"\u003e\n        \u003cspan class=\"hfm-num\"\u003e4\u003c\/span\u003e\n        \u003cspan\u003eTechnical Specifications Reference\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cp class=\"hfm-subtitle\"\u003ePerformance benchmarks of the shared 400–1000 nm hyperspectral optical core\u003c\/p\u003e\n\n      \u003cdiv class=\"hfm-table-wrap\"\u003e\n        \u003ctable class=\"hfm-table\"\u003e\n          \u003ctbody\u003e\n            \u003ctr\u003e\n              \u003ctd style=\"width: 35%;\"\u003eSpectral Range\u003c\/td\u003e\n              \u003ctd\u003e400–1000 nm continuous spectrum per pixel\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSpectral Resolution\u003c\/td\u003e\n              \u003ctd\u003eBetter than 2.3 nm (F\/2.4 aperture)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eDetector Technology\u003c\/td\u003e\n              \u003ctd\u003eTE-cooled sCMOS sensor, 16-bit dynamic range, 4×4 binning recommended\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSpatial Resolution \u0026amp; Bands\u003c\/td\u003e\n              \u003ctd\u003e512 spatial pixels per line; ≥300 spectral bands; spatial resolution \u0026lt;1 μm\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eFrame Rate\u003c\/td\u003e\n              \u003ctd\u003e72 fps full-spectrum acquisition\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eFluorescence Channels\u003c\/td\u003e\n              \u003ctd\u003e7 discrete channels; manual switching (FM) \/ motorized switching (FX)\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eIllumination System\u003c\/td\u003e\n              \u003ctd\u003e6-position reflected fluorescence illuminator; 12V \/ 100W halogen transmitted illumination\u003c\/td\u003e\n            \u003c\/tr\u003e\n            \u003ctr\u003e\n              \u003ctd\u003eSample Handling \u0026amp; Focus\u003c\/td\u003e\n              \u003ctd\u003eManual stage with 4-slide holder (FM) \/ Intelligent autofocus with 120-slide chamber (FX)\u003c\/td\u003e\n            \u003c\/tr\u003e\n          \u003c\/tbody\u003e\n        \u003c\/table\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Section 5: Frequently Asked Questions --\u003e\n    \u003cdiv class=\"hfm-section\"\u003e\n      \u003cdiv class=\"hfm-title\"\u003e\n        \u003cspan class=\"hfm-num\"\u003e5\u003c\/span\u003e\n        \u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cp class=\"hfm-subtitle\"\u003eCommon questions regarding hyperspectral unmixing and sample workflows\u003c\/p\u003e\n\n      \u003cdiv class=\"hfm-faq-item\"\u003e\n        \u003cdiv class=\"hfm-faq-q\"\u003eHow does the system eliminate spectral overlap between multiple fluorophores?\u003c\/div\u003e\n        \u003cdiv class=\"hfm-faq-a\"\u003e\n          Traditional fluorescence microscopy relies on bandpass optical filters that suffer from bleed-through when emission\n          spectra overlap. The RM-10-F measures the complete 400–1000 nm spectrum for each pixel. Dedicated unmixing algorithms\n          mathematically deconvolute overlapping fluorophores and endogenous autofluorescence without filter limitations.\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"hfm-faq-item\"\u003e\n        \u003cdiv class=\"hfm-faq-q\"\u003eCan autofluorescence be completely removed from formalin-fixed tissue?\u003c\/div\u003e\n        \u003cdiv class=\"hfm-faq-a\"\u003e\n          Yes. Tissue autofluorescence exhibits a broad, continuous spectral profile distinct from sharp fluorophore peaks.\n          The software treats autofluorescence as an independent component, subtracting it quantitatively to uncover faint\n          immunohistochemical targets.\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"hfm-faq-item\"\u003e\n        \u003cdiv class=\"hfm-faq-q\"\u003eCan virtual channels and image views be adjusted after data acquisition?\u003c\/div\u003e\n        \u003cdiv class=\"hfm-faq-a\"\u003e\n          Yes. Because the entire spectral data cube is saved, researchers can reconstruct custom pseudo-color channels,\n          change emission windows, or add new reference spectra at any time without re-staining or re-exposing samples.\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n\n      \u003cdiv class=\"hfm-faq-item\"\u003e\n        \u003cdiv class=\"hfm-faq-q\"\u003eWhen should a laboratory choose RM-10-FX over RM-10-FM?\u003c\/div\u003e\n        \u003cdiv class=\"hfm-faq-a\"\u003e\n          Choose the RM-10-FM for manual academic research and smaller slide sets. Choose the RM-10-FX when automated\n          throughput is essential: its 120-slide smart carousel, motorized switching, and intelligent autofocus enable\n          overnight, unattended batch scanning.\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- Ordering \/ Quote Box --\u003e\n    \u003cdiv class=\"hfm-note\"\u003e\n      \u003cstrong\u003eCustomized Spectral Analysis Workflows:\u003c\/strong\u003e\n      NWSPEC analytical specialists calibrate fluorophore reference libraries and spectral unmixing models\n      to your specific fluorochrome panel and tissue preparation prior to delivery.\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"hfm-cta\"\u003e\n      \u003ch3\u003eRequest an Application-Specific Technical Quotation\u003c\/h3\u003e\n      \u003cp\u003e\n        Describe your fluorophore panel, sample types, and daily slide throughput.\n        Our optical instrumentation team will configure the optimal objective set, stage automation, and provide a formal institutional quote.\n      \u003c\/p\u003e\n      \u003ca class=\"hfm-cta-btn\" href=\"mailto:sales@nwspec.com?subject=RM-10-F%20Hyperspectral%20Microscope%20Quotation%20Request\"\u003eRequest Quotation\u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":51254976610523,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/HyperspectralFluorescenceMicroscope.png?v=1795527992","url":"https:\/\/nwspec.com\/en-cn\/products\/rm-10-f-hyperspectral-fluorescence-microscope","provider":"NWSPEC","version":"1.0","type":"link"}