{"product_id":"sr68-nir-spectrometer-vs-nirquest","title":"SR68 NIR Spectrometer vs NIRQuest","description":"\u003cstyle\u003e\n  .product-page {\n    max-width: 1000px;\n    margin: 0 auto;\n    padding: 40px 20px;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, sans-serif;\n    color: #1a1a1a;\n    line-height: 1.6;\n  }\n  \n  .product-page h1 {\n    font-size: 36px;\n    font-weight: 700;\n    color: #000;\n    margin: 0 0 20px 0;\n    line-height: 1.2;\n  }\n  \n  .intro-text {\n    font-size: 18px;\n    color: #1a1a1a;\n    margin: 0 0 16px 0;\n    font-weight: 400;\n  }\n  \n  .intro-text strong {\n    color: #000;\n    font-weight: 600;\n  }\n  \n  .secondary-text {\n    font-size: 16px;\n    color: #333;\n    margin: 0 0 32px 0;\n  }\n  \n  .highlights-box {\n    background: #f5f5f5;\n    border-left: 4px solid #000;\n    padding: 24px 28px;\n    margin: 32px 0;\n  }\n  \n  .highlights-box h3 {\n    font-size: 20px;\n    font-weight: 700;\n    color: #000;\n    margin: 0 0 16px 0;\n    text-transform: uppercase;\n    letter-spacing: 0.5px;\n  }\n  \n  .highlights-box ul {\n    margin: 0;\n    padding-left: 20px;\n  }\n  \n  .highlights-box li {\n    margin-bottom: 8px;\n    font-size: 15px;\n  }\n  \n  .section-title {\n    font-size: 28px;\n    font-weight: 700;\n    color: #000;\n    margin: 48px 0 24px 0;\n    padding-bottom: 12px;\n    border-bottom: 3px solid #000;\n  }\n  \n  .feature-section {\n    margin: 32px 0;\n  }\n  \n  .feature-section h3 {\n    font-size: 20px;\n    font-weight: 700;\n    color: #000;\n    margin: 0 0 16px 0;\n    display: flex;\n    align-items: center;\n    gap: 12px;\n  }\n  \n  .feature-section h3::before {\n    content: \"\";\n    display: inline-block;\n    width: 8px;\n    height: 8px;\n    background: #000;\n    flex-shrink: 0;\n  }\n  \n  .feature-section ul {\n    margin: 0;\n    padding-left: 20px;\n  }\n  \n  .feature-section li {\n    margin-bottom: 10px;\n    font-size: 15px;\n    color: #333;\n  }\n  \n  .feature-section li strong {\n    color: #000;\n    font-weight: 600;\n  }\n  \n  .spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 24px 0;\n    box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n  }\n  \n  .spec-table thead {\n    background: #1a1a1a;\n    color: #fff;\n  }\n  \n  .spec-table th {\n    padding: 14px 16px;\n    text-align: left;\n    font-weight: 600;\n    font-size: 14px;\n    text-transform: uppercase;\n    letter-spacing: 0.5px;\n    border: none;\n  }\n  \n  .spec-table td {\n    padding: 12px 16px;\n    border: 1px solid #ddd;\n    font-size: 14px;\n  }\n  \n  .spec-table td:first-child {\n    font-weight: 600;\n    background: #fafafa;\n    width: 35%;\n  }\n  \n  .resolution-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 24px 0;\n    box-shadow: 0 1px 3px rgba(0,0,0,0.1);\n    font-size: 13px;\n  }\n  \n  .resolution-table thead {\n    background: #1a1a1a;\n    color: #fff;\n  }\n  \n  .resolution-table th {\n    padding: 12px 8px;\n    text-align: center;\n    font-weight: 600;\n    font-size: 12px;\n    text-transform: uppercase;\n    letter-spacing: 0.5px;\n    border: none;\n  }\n  \n  .resolution-table td {\n    padding: 10px 8px;\n    text-align: center;\n    border: 1px solid #ddd;\n  }\n  \n  .resolution-table td:first-child {\n    font-weight: 600;\n    background: #fafafa;\n    text-align: left;\n  }\n  \n  .resolution-table tbody tr:nth-child(even) {\n    background: #fafafa;\n  }\n  \n  .resolution-table .model-header {\n    background: #333;\n    color: #fff;\n    font-weight: 700;\n    text-align: left;\n    padding: 12px 16px;\n  }\n  \n  .pixel-options {\n    display: flex;\n    gap: 20px;\n    margin: 24px 0;\n    flex-wrap: wrap;\n  }\n  \n  .pixel-card {\n    flex: 1;\n    min-width: 280px;\n    background: #fafafa;\n    border: 2px solid #1a1a1a;\n    padding: 20px;\n    text-align: center;\n  }\n  \n  .pixel-card h4 {\n    font-size: 18px;\n    font-weight: 700;\n    color: #000;\n    margin: 0 0 12px 0;\n    padding-bottom: 8px;\n    border-bottom: 2px solid #000;\n  }\n  \n  .pixel-card .pixel-number {\n    font-size: 32px;\n    font-weight: 700;\n    color: #000;\n    margin: 16px 0;\n  }\n  \n  .pixel-card p {\n    font-size: 14px;\n    color: #333;\n    margin: 0;\n    line-height: 1.5;\n  }\n  \n  @media (max-width: 768px) {\n    .product-page h1 {\n      font-size: 28px;\n    }\n    \n    .spec-table,\n    .resolution-table {\n      font-size: 12px;\n    }\n    \n    .resolution-table {\n      display: block;\n      overflow-x: auto;\n      white-space: nowrap;\n    }\n    \n    .pixel-options {\n      flex-direction: column;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"product-page\"\u003e\n\u003ch1\u003eSR68: High-Performance NIR Spectrometer for Demanding Applications\u003c\/h1\u003e\n\u003cp class=\"intro-text\"\u003e\u003cstrong\u003eAchieve unparalleled NIR analysis with extended wavelength coverage.\u003c\/strong\u003e The SR68 series of miniature fiber-optic spectrometers is equipped with a two-stage cooled InGaAs detector, delivering high-speed, accurate results in the 900-2500 nm range.\u003c\/p\u003e\n\u003cp class=\"secondary-text\"\u003eIdeal for demanding industrial online monitoring and precise agricultural analysis, the SR68 combines advanced cooling technology with high sensitivity to provide exceptional performance for near-infrared spectroscopy applications.\u003c\/p\u003e\n\u003cdiv class=\"highlights-box\"\u003e\n\u003ch3\u003eProduct Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtended NIR Coverage:\u003c\/strong\u003e Multiple near-infrared bands available from 900-2500 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Cooling:\u003c\/strong\u003e Advanced thermoelectric cooling for enhanced detector performance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInGaAs Detector:\u003c\/strong\u003e High-sensitivity detection optimized for NIR wavelengths\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Noise:\u003c\/strong\u003e Minimized dark current for improved measurement accuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Signal-to-Noise Ratio:\u003c\/strong\u003e 3500:1 for precise quantitative analysis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Temperature Drift:\u003c\/strong\u003e Stable performance under varying conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Pixel Options:\u003c\/strong\u003e 256, 512, and 1024 pixel configurations available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eAvailable Configurations\u003c\/h2\u003e\n\u003cdiv class=\"pixel-options\"\u003e\n\u003cdiv class=\"pixel-card\"\u003e\n\u003ch4\u003eStandard Resolution\u003c\/h4\u003e\n\u003cdiv class=\"pixel-number\"\u003e256 pixels\u003c\/div\u003e\n\u003cp\u003eBalanced performance for general NIR applications with excellent sensitivity and speed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pixel-card\"\u003e\n\u003ch4\u003eEnhanced Resolution\u003c\/h4\u003e\n\u003cdiv class=\"pixel-number\"\u003e512 pixels\u003c\/div\u003e\n\u003cp\u003eImproved spectral resolution for detailed analysis and complex sample characterization.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pixel-card\"\u003e\n\u003ch4\u003eHigh Resolution\u003c\/h4\u003e\n\u003cdiv class=\"pixel-number\"\u003e1024 pixels\u003c\/div\u003e\n\u003cp\u003eMaximum resolution for demanding applications requiring precise spectral feature identification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eApplications\u003c\/h2\u003e\n\u003cdiv class=\"feature-section\"\u003e\n\u003ch3\u003eAgriculture \u0026amp; Food\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Content Analysis:\u003c\/strong\u003e Precise moisture measurement in various materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFruit Detection:\u003c\/strong\u003e Non-destructive quality assessment of fruits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrop Detection:\u003c\/strong\u003e Agricultural monitoring and quality control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-section\"\u003e\n\u003ch3\u003eIndustrial \u0026amp; Scientific\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Laser Wavelength Detection:\u003c\/strong\u003e Telecom component characterization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnline Component Analysis:\u003c\/strong\u003e Real-time process monitoring and control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChemical Concentration Online Detection:\u003c\/strong\u003e Quantitative analysis of chemical processes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRaman Spectroscopy Application:\u003c\/strong\u003e Molecular analysis in NIR region\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLife Science Instruments:\u003c\/strong\u003e Integration into biomedical research equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScientific Experiments:\u003c\/strong\u003e Versatile platform for research applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Detection:\u003c\/strong\u003e Monitoring of environmental parameters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfrared Light Source Detection:\u003c\/strong\u003e Characterization of NIR sources\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"feature-section\"\u003e\n\u003ch3\u003eDetector Technology\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Near-Infrared Bands:\u003c\/strong\u003e Available configurations covering 900-1700 nm, 1430-1750 nm, and 900-2500 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo-Stage Cooling:\u003c\/strong\u003e Maintains optimal detector temperature for reduced noise\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInGaAs Detector:\u003c\/strong\u003e Specialized for high-sensitivity NIR detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Noise:\u003c\/strong\u003e Advanced cooling minimizes dark current for superior sensitivity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Pixel Options:\u003c\/strong\u003e 256, 512, or 1024 pixels to match application requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-section\"\u003e\n\u003ch3\u003ePerformance Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Signal-to-Noise Ratio:\u003c\/strong\u003e 3500:1 ensures accurate measurements even with low signal levels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Temperature Drift:\u003c\/strong\u003e Maintains calibration and accuracy across temperature variations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Dynamic Range:\u003c\/strong\u003e 100,000:1 for analysis of samples with wide concentration ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Integration:\u003c\/strong\u003e 0.4 ms - 1000 ms adjustable integration time\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"section-title\"\u003eOptical Resolution by Model\u003c\/h2\u003e\n\u003ctable class=\"resolution-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpectrometer Model\u003c\/th\u003e\n\u003cth\u003eRange (nm)\u003c\/th\u003e\n\u003cth\u003e30 μm\u003c\/th\u003e\n\u003cth\u003e40 μm\u003c\/th\u003e\n\u003cth\u003e50 μm\u003c\/th\u003e\n\u003cth\u003e60 μm\u003c\/th\u003e\n\u003cth\u003e70 μm\u003c\/th\u003e\n\u003cth\u003e100 μm\u003c\/th\u003e\n\u003cth\u003e150 μm\u003c\/th\u003e\n\u003cth\u003e200 μm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"model-header\" colspan=\"10\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eSR68 NIR Spectrometer (256 pixels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e900-1700 nm（256pixels)\u003c\/td\u003e\n\u003ctd\u003e6.5 nm\u003c\/td\u003e\n\u003ctd\u003e6.5 nm\u003c\/td\u003e\n\u003ctd\u003e7.0 nm\u003c\/td\u003e\n\u003ctd\u003e8.0 nm\u003c\/td\u003e\n\u003ctd\u003e9.0 nm\u003c\/td\u003e\n\u003ctd\u003e10.0 nm\u003c\/td\u003e\n\u003ctd\u003e11.0 nm\u003c\/td\u003e\n\u003ctd\u003e12.5 nm\u003c\/td\u003e\n\u003ctd\u003e14.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1430-1700 nm（256pixels)\u003c\/td\u003e\n\u003ctd\u003e3.2 nm\u003c\/td\u003e\n\u003ctd\u003e3.2 nm\u003c\/td\u003e\n\u003ctd\u003e3.5 nm\u003c\/td\u003e\n\u003ctd\u003e4.0 nm\u003c\/td\u003e\n\u003ctd\u003e4.5 nm\u003c\/td\u003e\n\u003ctd\u003e5.0 nm\u003c\/td\u003e\n\u003ctd\u003e5.5 nm\u003c\/td\u003e\n\u003ctd\u003e6.3 nm\u003c\/td\u003e\n\u003ctd\u003e7.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e900-2500 nm\u003c\/td\u003e\n\u003ctd\u003e15.0 nm\u003c\/td\u003e\n\u003ctd\u003e15.0 nm\u003c\/td\u003e\n\u003ctd\u003e16.0 nm\u003c\/td\u003e\n\u003ctd\u003e17.0 nm\u003c\/td\u003e\n\u003ctd\u003e18.0 nm\u003c\/td\u003e\n\u003ctd\u003e19.0 nm\u003c\/td\u003e\n\u003ctd\u003e22.0 nm\u003c\/td\u003e\n\u003ctd\u003e24.5 nm\u003c\/td\u003e\n\u003ctd\u003e27.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"model-header\" colspan=\"10\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eSR68 NIR Spectrometer (512 pixels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e900-1700 nm\u003c\/td\u003e\n\u003ctd\u003e5.0 nm\u003c\/td\u003e\n\u003ctd\u003e5.0 nm\u003c\/td\u003e\n\u003ctd\u003e5.4 nm\u003c\/td\u003e\n\u003ctd\u003e5.8 nm\u003c\/td\u003e\n\u003ctd\u003e6.0 nm\u003c\/td\u003e\n\u003ctd\u003e6.3 nm\u003c\/td\u003e\n\u003ctd\u003e7.8 nm\u003c\/td\u003e\n\u003ctd\u003e10.5 nm\u003c\/td\u003e\n\u003ctd\u003e13.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1430-1700 nm\u003c\/td\u003e\n\u003ctd\u003e2.5 nm\u003c\/td\u003e\n\u003ctd\u003e2.5 nm\u003c\/td\u003e\n\u003ctd\u003e2.9 nm\u003c\/td\u003e\n\u003ctd\u003e3.3 nm\u003c\/td\u003e\n\u003ctd\u003e3.7 nm\u003c\/td\u003e\n\u003ctd\u003e3.9 nm\u003c\/td\u003e\n\u003ctd\u003e4.5 nm\u003c\/td\u003e\n\u003ctd\u003e5.7 nm\u003c\/td\u003e\n\u003ctd\u003e7.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"model-header\" colspan=\"10\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eSR68 NIR Spectrometer (1024 pixels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e900-1700 nm\u003c\/td\u003e\n\u003ctd\u003e2.6 nm\u003c\/td\u003e\n\u003ctd\u003e2.6 nm\u003c\/td\u003e\n\u003ctd\u003e3.1 nm\u003c\/td\u003e\n\u003ctd\u003e3.3 nm\u003c\/td\u003e\n\u003ctd\u003e3.6 nm\u003c\/td\u003e\n\u003ctd\u003e3.8 nm\u003c\/td\u003e\n\u003ctd\u003e4.8 nm\u003c\/td\u003e\n\u003ctd\u003e7.8 nm\u003c\/td\u003e\n\u003ctd\u003e10.3 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSpectral Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Range\u003c\/td\u003e\n\u003ctd\u003e900 - 2500 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Resolution\u003c\/td\u003e\n\u003ctd\u003eMaximum 1.25 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Resolution\u003c\/td\u003e\n\u003ctd\u003eMaximum 3.20 nm FWHM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigher-Order Diffraction\u003c\/td\u003e\n\u003ctd\u003eAdd high-order diffraction filter (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray Light\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eDetector Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Model\u003c\/td\u003e\n\u003ctd\u003eInGaAs detector (optional configurations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Detection Range\u003c\/td\u003e\n\u003ctd\u003e900 - 2500 nm (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePixel Options\u003c\/td\u003e\n\u003ctd\u003e256 pixels \/ 512 pixels \/ 1024 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePixel Size (256 pixels)\u003c\/td\u003e\n\u003ctd\u003e50 × 250 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Sensitivity\u003c\/td\u003e\n\u003ctd\u003e10.5 μV\/e⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Speed\u003c\/td\u003e\n\u003ctd\u003e1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eOptical Parameters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Path\u003c\/td\u003e\n\u003ctd\u003eF\/4, symmetrical crossed Czerny-Turner optical path\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocal Length\u003c\/td\u003e\n\u003ctd\u003e100 mm; 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncident Slit\u003c\/td\u003e\n\u003ctd\u003eStandard 200 μm (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Fiber\u003c\/td\u003e\n\u003ctd\u003eNear-infrared SMA905 0.22 NA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eElectronic Properties\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal-to-Noise Ratio\u003c\/td\u003e\n\u003ctd\u003e3500:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration Time\u003c\/td\u003e\n\u003ctd\u003e0.4 ms - 1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD Converter\u003c\/td\u003e\n\u003ctd\u003eNo distortion 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Speed\u003c\/td\u003e\n\u003ctd\u003e2.8 ms + integration time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Interface\u003c\/td\u003e\n\u003ctd\u003e16-pin external expansion interface with external trigger function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e450 mA @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Power\u003c\/td\u003e\n\u003ctd\u003e4 A @ 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePhysical Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Systems\u003c\/td\u003e\n\u003ctd\u003eWindows, Android, Linux, Wince\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e182 × 110 × 50 mm (7.2 × 4.3 × 2.0 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1500 g (3.31 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e3-direction standard installation holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":47301443027163,"sku":null,"price":21250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/SR68.jpg?v=1772696854","url":"https:\/\/nwspec.com\/en-cn\/products\/sr68-nir-spectrometer-vs-nirquest","provider":"NWSPEC","version":"1.0","type":"link"}