{"product_id":"triple-quadrupole-lc-ms-ms-for-food-safety-pharma-clinical-analysis-tq50","title":"Triple Quadrupole LC-MS\/MS for Food Safety, Pharma \u0026 Clinical Analysis | TQ50","description":"\u003cstyle\u003e\n  .tq50-guide-container {\n    max-width: 1000px;\n    margin: 0 auto;\n    font-family: Arial, sans-serif;\n    color: #000;\n    line-height: 1.5;\n    padding: 20px;\n  }\n  \n  \/* Header *\/\n  .tq50-header {\n    border-bottom: 3px solid #000;\n    padding-bottom: 20px;\n    margin-bottom: 30px;\n  }\n  \n  .tq50-title {\n    font-size: 32px;\n    font-weight: bold;\n    margin: 0 0 10px 0;\n    letter-spacing: -0.5px;\n  }\n  \n  .tq50-subtitle {\n    font-size: 16px;\n    color: #333;\n    margin: 0;\n    font-weight: normal;\n  }\n  \n  \/* Lead Section *\/\n  .tq50-lead {\n    font-size: 15px;\n    line-height: 1.7;\n    margin: 25px 0;\n    padding: 20px;\n    background: #f9f9f9;\n    border-left: 4px solid #000;\n  }\n  \n  \/* Section Styling *\/\n  .tq50-section {\n    margin: 40px 0;\n  }\n  \n  .tq50-section-title {\n    font-size: 20px;\n    font-weight: bold;\n    margin: 0 0 20px 0;\n    text-transform: uppercase;\n    letter-spacing: 1px;\n    border-bottom: 2px solid #000;\n    padding-bottom: 8px;\n  }\n  \n  \/* Application Cards *\/\n  .app-grid {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(280px, 1fr));\n    gap: 15px;\n    margin: 20px 0;\n  }\n  \n  .app-card {\n    border: 2px solid #000;\n    padding: 20px;\n    background: #fff;\n    transition: all 0.2s ease;\n  }\n  \n  .app-card:hover {\n    background: #000;\n    color: #fff;\n  }\n  \n  .app-card h4 {\n    font-size: 14px;\n    font-weight: bold;\n    margin: 0 0 8px 0;\n    text-transform: uppercase;\n  }\n  \n  .app-card p {\n    font-size: 13px;\n    margin: 0;\n    line-height: 1.5;\n  }\n  \n  \/* Specs Table *\/\n  .specs-table {\n    width: 100%;\n    border-collapse: collapse;\n    font-size: 14px;\n    margin: 20px 0;\n  }\n  \n  .specs-table th {\n    background: #000;\n    color: #fff;\n    padding: 12px 15px;\n    text-align: left;\n    font-weight: bold;\n    text-transform: uppercase;\n    font-size: 12px;\n    letter-spacing: 0.5px;\n  }\n  \n  .specs-table td {\n    padding: 12px 15px;\n    border-bottom: 1px solid #ddd;\n  }\n  \n  .specs-table tr:nth-child(even) {\n    background: #f5f5f5;\n  }\n  \n  .specs-table td:first-child {\n    font-weight: bold;\n    width: 35%;\n  }\n  \n  \/* Why Choose Section *\/\n  .why-grid {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(220px, 1fr));\n    gap: 20px;\n    margin: 25px 0;\n  }\n  \n  .why-item {\n    text-align: center;\n    padding: 25px 15px;\n    border: 2px solid #000;\n  }\n  \n  .why-number {\n    font-size: 36px;\n    font-weight: bold;\n    display: block;\n    margin-bottom: 10px;\n  }\n  \n  .why-label {\n    font-size: 13px;\n    font-weight: bold;\n    text-transform: uppercase;\n    letter-spacing: 0.5px;\n  }\n  \n  \/* CTA Section *\/\n  .cta-section {\n    background: #000;\n    color: #fff;\n    padding: 35px;\n    margin-top: 40px;\n    text-align: center;\n  }\n  \n  .cta-title {\n    font-size: 22px;\n    font-weight: bold;\n    margin: 0 0 15px 0;\n  }\n  \n  .cta-text {\n    font-size: 15px;\n    margin: 0 0 25px 0;\n    line-height: 1.6;\n  }\n  \n  .cta-button {\n    display: inline-block;\n    background: #fff;\n    color: #000;\n    padding: 15px 40px;\n    text-decoration: none;\n    font-weight: bold;\n    font-size: 14px;\n    text-transform: uppercase;\n    letter-spacing: 1px;\n    border: 2px solid #fff;\n    transition: all 0.2s ease;\n  }\n  \n  .cta-button:hover {\n    background: #000;\n    color: #fff;\n  }\n  \n  \/* Comparison Note *\/\n  .comparison-box {\n    border: 2px solid #000;\n    padding: 20px;\n    margin: 30px 0;\n    background: #fff;\n  }\n  \n  .comparison-box h3 {\n    font-size: 14px;\n    font-weight: bold;\n    margin: 0 0 10px 0;\n    text-transform: uppercase;\n  }\n  \n  .comparison-box p {\n    font-size: 13px;\n    margin: 0;\n    line-height: 1.6;\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"tq50-guide-container\"\u003e\n\n  \u003c!-- Header --\u003e\n  \u003cdiv class=\"tq50-header\"\u003e\n    \u003ch1 class=\"tq50-title\"\u003eTQ50 — UHPLC Triple Quadrupole MS\u003c\/h1\u003e\n    \u003cp class=\"tq50-subtitle\"\u003eSub-ppb Detection | True MS\/MS Capability | 0.4 FWHM Resolution\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Lead --\u003e\n  \u003cdiv class=\"tq50-lead\"\u003e\n    \u003cstrong\u003eChoose TQ50 when you need definitive compound identification.\u003c\/strong\u003e Unlike single-quadrupole systems limited to unit mass resolution, TQ50 delivers true MS\/MS performance with 0.4 FWHM resolution. The triple quadrupole architecture enables precursor and product ion monitoring for unambiguous quantification in complex matrices — from pesticide residues in food to therapeutic drugs in clinical samples.\n  \u003c\/div\u003e\n\n  \u003c!-- Applications --\u003e\n  \u003cdiv class=\"tq50-section\"\u003e\n    \u003ch2 class=\"tq50-section-title\"\u003eSelect Your Application\u003c\/h2\u003e\n    \u003cdiv class=\"app-grid\"\u003e\n      \u003cdiv class=\"app-card\"\u003e\n        \u003ch4\u003eFood Safety\u003c\/h4\u003e\n        \u003cp\u003ePesticide residues, veterinary drugs, mycotoxins, illegal additives\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"app-card\"\u003e\n        \u003ch4\u003eEnvironmental\u003c\/h4\u003e\n        \u003cp\u003eWater quality monitoring, soil contaminants, PFAS, emerging pollutants\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"app-card\"\u003e\n        \u003ch4\u003eClinical Diagnostics\u003c\/h4\u003e\n        \u003cp\u003eTherapeutic drug monitoring, newborn screening, biomarker quantification\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"app-card\"\u003e\n        \u003ch4\u003ePharmaceutical\u003c\/h4\u003e\n        \u003cp\u003eImpurity profiling, pharmacokinetics, metabolite identification\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"app-card\"\u003e\n        \u003ch4\u003eForensic Toxicology\u003c\/h4\u003e\n        \u003cp\u003eDrugs of abuse confirmation, poison detection, trace evidence\u003c\/p\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"app-card\"\u003e\n        \u003ch4\u003eResearch\u003c\/h4\u003e\n        \u003cp\u003eTargeted metabolomics, proteomics quantification, biomarker discovery\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Key Advantages --\u003e\n  \u003cdiv class=\"tq50-section\"\u003e\n    \u003ch2 class=\"tq50-section-title\"\u003eWhy TQ50\u003c\/h2\u003e\n    \u003cdiv class=\"why-grid\"\u003e\n      \u003cdiv class=\"why-item\"\u003e\n        \u003cspan class=\"why-number\"\u003e0.4\u003c\/span\u003e\n        \u003cspan class=\"why-label\"\u003eFWHM Resolution\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"why-item\"\u003e\n        \u003cspan class=\"why-number\"\u003e2ms\u003c\/span\u003e\n        \u003cspan class=\"why-label\"\u003eChannel Switching\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"why-item\"\u003e\n        \u003cspan class=\"why-number\"\u003e0.1fg\u003c\/span\u003e\n        \u003cspan class=\"why-label\"\u003eDetection Limit\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"why-item\"\u003e\n        \u003cspan class=\"why-number\"\u003e0.86%\u003c\/span\u003e\n        \u003cspan class=\"why-label\"\u003eRT Reproducibility\u003c\/span\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Comparison --\u003e\n  \u003cdiv class=\"comparison-box\"\u003e\n    \u003ch3\u003eSingle Quad vs. Triple Quad\u003c\/h3\u003e\n    \u003cp\u003eSingle quadrupole systems provide mass filtering only — suitable for simple matrices with known interferences. TQ50's triple quadrupole architecture adds a dedicated collision cell for MS\/MS fragmentation, eliminating matrix interferences through MRM transitions. This enables reliable quantification at sub-ppb levels in complex samples where single quad systems fail.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- Technical Specifications --\u003e\n  \u003cdiv class=\"tq50-section\"\u003e\n    \u003ch2 class=\"tq50-section-title\"\u003eTechnical Specifications\u003c\/h2\u003e\n    \u003ctable class=\"specs-table\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth\u003eParameter\u003c\/th\u003e\n          \u003cth\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMass Range\u003c\/td\u003e\n          \u003ctd\u003e2–1500 amu (standard) \/ 2–2000 amu (extended)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eResolution\u003c\/td\u003e\n          \u003ctd\u003e0.4 \/ 0.7 \/ 1.5 FWHM (user selectable)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eScan Speed\u003c\/td\u003e\n          \u003ctd\u003e\u0026gt;19,000 amu\/second\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eMass Stability\u003c\/td\u003e\n          \u003ctd\u003e±0.05 amu per 24 hours\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eReproducibility\u003c\/td\u003e\n          \u003ctd\u003eRT RSD 0.86%, Peak Area RSD 1.89% (200 injections)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eIon Source\u003c\/td\u003e\n          \u003ctd\u003eESI\/APCI interchangeable, 400°C, 3D adjustable probe\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eCollision Cell\u003c\/td\u003e\n          \u003ctd\u003eSegmented quadrupole, fast ion transport, reduced cross-talk\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eDetector\u003c\/td\u003e\n          \u003ctd\u003eOff-axis HED + ion counter, 5 orders dynamic range\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003ePump System\u003c\/td\u003e\n          \u003ctd\u003eDual-piston linear drive, vacuum degassing, seal wash\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- CTA --\u003e\n  \u003cdiv class=\"cta-section\"\u003e\n    \u003ch3 class=\"cta-title\"\u003eConfigure Your TQ50 System\u003c\/h3\u003e\n    \u003cp class=\"cta-text\"\u003eSelect mass range, ionization mode, and application-specific method packages. Our team will provide a customized quotation based on your analytical requirements.\u003c\/p\u003e\n    \u003ca href=\"#\" class=\"cta-button\"\u003eRequest Technical Quote\u003c\/a\u003e\n  \u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":48510370447579,"sku":null,"price":215000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/TQ50.png?v=1777461220","url":"https:\/\/nwspec.com\/en-cn\/products\/triple-quadrupole-lc-ms-ms-for-food-safety-pharma-clinical-analysis-tq50","provider":"NWSPEC","version":"1.0","type":"link"}