{"product_id":"fully-automated-nitrogen-purging-concentrator","title":"Fully Automated Nitrogen Purging Concentrator","description":"\u003cdiv style=\"font-family: Arial,sans-serif; color: #333; line-height: 1.7; max-width: 800px; margin: 0 auto; padding: 0 20px;\"\u003e\n\u003c!-- HEADER --\u003e\n\u003cdiv style=\"border-bottom: 3px solid #000; padding: 40px 0 20px; margin-bottom: 40px;\"\u003e\n\u003ch1 style=\"font-size: 32px; font-weight: 800; color: #000; margin: 0 0 12px; line-height: 1.2;\"\u003eFully Automated Nitrogen Purging Concentrator — PrepN Series\u003c\/h1\u003e\n\u003cp style=\"font-size: 16px; color: #555; margin: 0;\"\u003eRapid, unattended sample concentration with vortex airflow and patented end-point detection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 3 HIGHLIGHTS --\u003e\n\u003cdiv style=\"display: flex; gap: 20px; margin-bottom: 50px; flex-wrap: wrap;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e192\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eSamples per batch (PrepN-96)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e90 °C\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eMaximum water bath temperature\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e\u0026lt;20 min\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eWarm-up time (20 to 55 °C)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- WHY AUTOMATE --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 20px;\"\u003eWhy Automate Your Concentration Workflow\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 12px; color: #555;\"\u003eManual nitrogen blow-down concentration requires constant attention: adjust needle height, monitor each tube, stop before dryness, and transfer to vials. One distracted moment means lost sample or cross-contamination.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 20px; color: #555;\"\u003eBatch-to-batch consistency is poor, evaporation times vary, and analysts spend hours watching tubes instead of interpreting data. Over-drying and bumping are common risks.\u003c\/p\u003e\n\u003cdiv style=\"background: #f5f5f5; border-left: 4px solid #000; padding: 16px 20px; margin-bottom: 50px;\"\u003e\n\u003cstrong style=\"color: #000; display: block; margin-bottom: 8px;\"\u003eWith full automation:\u003c\/strong\u003e\n\u003cp style=\"margin: 0; color: #444;\"\u003eLoad tubes or well plates. Set temperature and pressure. Press start. Walk away. Optical end-point detection stops each channel precisely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 6 STEPS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eWhat the System Does\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eLoad\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003ePlace tubes or 96-well plates into the rack. Supports 8 to 192 positions depending on model\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eSet Parameters\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eProgram water bath temperature (ambient to 90 °C), purge pressure, and end-point volume via touchscreen\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eNitrogen Purge\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eVortex airflow technology delivers consistent gas flow to each needle. Automatic pressure regulation with gradient adjustment\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eHeat\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eDouble-layer water bath or hot-air heating accelerates evaporation. Temperature monitored in real time\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eEnd-Point Detection\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003ePatented optical sensor detects 0.5 mL or 1.0 mL residual volume per channel automatically. No over-drying\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e6\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eCollect\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eSamples concentrated directly in chromatography vials. No secondary transfer needed. Ready for LC-MS\/MS or GC-MS\/MS injection\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- KEY FEATURES --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eKey Features\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 50px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000; width: 45%;\"\u003eNumber of samples\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e8 \/ 12 \/ 24 \/ 60 \/ 192 (PrepN-8 to PrepN-96)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eMaximum sample volume\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e250 mL \/ 200 mL \/ 100 mL \/ 60 mL \/ 2 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eEnd-point detection\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eOptional on PrepN-8\/12\/24\/60; standard on PrepN-96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eIndependent control\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003ePer-channel or per-row independent concentration paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eTouch screen\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e7-inch color touchscreen, angle adjustable 0–85°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eWater bath temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eAmbient to 90 °C (PrepN-8\/12\/24\/60); ambient to 80 °C (PrepN-96)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003ePurge pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eMulti-stage adjustable; max intake 0.31 MPa (45 PSI) \/ 0.8 MPa (116 PSI) on PrepN-96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eAC 100–240 V, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eOverall power\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e900 W (PrepN-8\/12\/24\/60); 1000 W (PrepN-96)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eAmbient to 40 °C, 20–80% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eNoise\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e≤ 70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e465 × 430 × 300 mm (PrepN-8\/12\/24\/60); 430 × 430 × 300 mm (PrepN-96)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eMachine weight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e~30 kg (PrepN-8\/12\/24\/60); ~32 kg (PrepN-96)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eWhat You Can Test\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdiv style=\"padding: 16px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eEnvironmental Analysis\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eConcentration of water, soil, and sediment extracts prior to GC-MS or LC-MS analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eFood and Beverage\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003ePesticide residue and additive extract concentration for fruits, vegetables, grains, and beverages.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eBiological and Clinical\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eBlood, urine, and tissue extract concentration for drug metabolism and toxicology studies.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px 0;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eChemical Engineering and Testing\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eSolvent removal from reaction mixtures and quality-control sample preparation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- COMPLIANCE --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 20px;\"\u003eCompliance and Data Integrity\u003c\/h2\u003e\n\u003cul style=\"margin: 0 0 50px; padding-left: 20px; color: #555; font-size: 14px; line-height: 2;\"\u003e\n\u003cli\u003eCE certified for EU market compliance\u003c\/li\u003e\n\u003cli\u003ePatented optical end-point sensor technology for precise volume determination\u003c\/li\u003e\n\u003cli\u003eTransparent window and water bath illumination for real-time process observation\u003c\/li\u003e\n\u003cli\u003eAutomatic pressure regulation with gradient purge airflow optimization\u003c\/li\u003e\n\u003cli\u003eUser-friendly interactive software with adjustable touchscreen angle\u003c\/li\u003e\n\u003cli\u003eCompatible with chromatography vial concentration tubes — no secondary transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eCommon Questions\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdetails open=\"\" style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eWhat tube sizes are supported? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e-\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003ePrepN-8\/12\/24\/60 support 50 mL to 200 mL tubes plus dedicated chromatography vial tubes. PrepN-96 supports standard 96 deep-well and shallow-well plates. Built-in and external racks are available for all formats.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eHow does end-point detection work? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eA patented optical sensor monitors each channel individually. When the liquid level reaches the preset 0.5 mL or 1.0 mL mark, nitrogen flow to that channel stops automatically. No over-drying, no sample loss, no operator attendance required.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eCan I change samples mid-run? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. Independent concentration paths do not interfere with each other. Samples can be changed in less than 30 seconds per channel without stopping the entire batch.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eIs the nitrogen needle angle adjustable? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. Air nozzles are removable, and airflow angle plus left\/right position can be precisely adjusted to match tube geometry and sample volume.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eCan it connect to other NWSPEC systems? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. PrepN is designed for interconnection with other NWSPEC sample preparation systems such as PrepS and PrepV for seamless end-to-end workflows.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eWhat gas supply is required? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eHigh-purity nitrogen or other inert gases are recommended. Minimum pressure 0.15 MPa (21 PSI), maximum allowable 0.31 MPa (45 PSI) for standard models and 0.8 MPa (116 PSI) for PrepN-96.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c!-- FOOTER NOTE --\u003e\n\u003cdiv style=\"border-top: 2px solid #000; padding: 30px 0 40px; text-align: center;\"\u003e\n\u003cp style=\"font-size: 16px; font-weight: bold; color: #000; margin: 0 0 8px;\"\u003eCustom method development and application consulting available.\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; color: #888; margin: 0;\"\u003eCompatible with LC-MS\/MS and GC-MS\/MS analytical platforms\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":49125347721435,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/A60.png?v=1786438984","url":"https:\/\/nwspec.com\/products\/fully-automated-nitrogen-purging-concentrator","provider":"NWSPEC","version":"1.0","type":"link"}