{"product_id":"fully-automated-spe","title":"Fully Automated SPE","description":"\u003cdiv style=\"font-family: Arial,sans-serif; color: #333; line-height: 1.7; max-width: 800px; margin: 0 auto; padding: 0 20px;\"\u003e\n\u003c!-- HEADER --\u003e\n\u003cdiv style=\"border-bottom: 3px solid #000; padding: 40px 0 20px; margin-bottom: 40px;\"\u003e\n\u003ch1 style=\"font-size: 32px; font-weight: 800; color: #000; margin: 0 0 12px; line-height: 1.2;\"\u003eFully Automated Solid Phase Extraction System — PrepS Series\u003c\/h1\u003e\n\u003cp style=\"font-size: 16px; color: #555; margin: 0;\"\u003eWalkaway SPE automation from activation to elution. High sample recovery. Full parameter editing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 3 HIGHLIGHTS --\u003e\n\u003cdiv style=\"display: flex; gap: 20px; margin-bottom: 50px; flex-wrap: wrap;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e80\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eSamples per batch, unattended\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e20 L\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eMaximum sample volume per run\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e4\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eModels: 2 \/ 4 \/ 6 \/ 8 channels\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- WHY AUTOMATE --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 20px;\"\u003eWhy Automate Your SPE Workflow\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 12px; color: #555;\"\u003eManual solid phase extraction means repetitive hands-on work: condition cartridges, load samples, wash, dry, elute, collect — all while watching for drips, back-pressure, and inconsistent flow rates.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 20px; color: #555;\"\u003eEvery manual step adds variability, risk of cross-contamination, and ties up skilled analysts for hours. Recovery rates fluctuate batch to batch, and method traceability is limited.\u003c\/p\u003e\n\u003cdiv style=\"background: #f5f5f5; border-left: 4px solid #000; padding: 16px 20px; margin-bottom: 50px;\"\u003e\n\u003cstrong style=\"color: #000; display: block; margin-bottom: 8px;\"\u003eWith full automation:\u003c\/strong\u003e\n\u003cp style=\"margin: 0; color: #444;\"\u003eLoad cartridges and samples. Select method. Press start. Collect purified extracts. Walk away.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 6 STEPS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eWhat the System Does\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eActivate\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eAutomated conditioning of SPE cartridges with solvent, programmable volume and flow rate\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eLoad\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003ePrecise sample loading via injection pump module. Supports large-volume module up to 20 L\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eWash\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eProgrammable wash steps with multiple reagent channels. Anti-permeation flow path prevents reflux\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eBlow-Dry\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eAutomated nitrogen blow-drying of cartridges. Pressure and time fully editable per method\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eElute\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eAccurate elution into collection tubes. Automatic quantitative concentration at 1 \/ 3 \/ 6 \/ 10 \/ 12 \/ 20 mL\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e6\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eCollect\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eMulti-format collection rack (10–50 mL tubes). Compatible with downstream LC-MS\/MS and GC-MS\/MS\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- KEY FEATURES --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eKey Features\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 50px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000; width: 45%;\"\u003eNumber of channels\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e2 \/ 4 \/ 6 \/ 8 (PrepS-2 to PrepS-8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eMaximum extraction columns\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e20 \/ 40 \/ 60 \/ 80 per batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eMaximum sample volume\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e20 L per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eAutomatic quantitative concentration\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e1 \/ 3 \/ 6 \/ 10 \/ 12 \/ 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eCollection tube volume\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e10 mL to 50 mL (10–35 mL on PrepS-8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eReagent channels\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e8 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eTouch screen\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eAdjustable angle, full-color interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eMaximum intake pressure\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e0.7 MPa (100 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eAC 100–240 V, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eOverall power\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e100 W \/ 120 W \/ 130 W \/ 140 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eAmbient to 40 °C, 20–80% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eNoise\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e≤ 50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e473×600×731 \/ 593×600×731 \/ 773×600×731 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eMachine weight\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e~72 kg \/ ~90 kg \/ ~110 kg \/ ~115 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eWhat You Can Test\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdiv style=\"padding: 16px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eWater and Environmental\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eTrace organics, pesticides, and pollutants in drinking water, wastewater, and environmental samples.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eFood and Beverage\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003ePesticide residues, additives, and contaminants in fruits, vegetables, grains, and beverages.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eClinical and Biological\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eDrug metabolites, toxins, and biomarkers in blood, urine, and biological fluids.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px 0;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eSoil and Sediment\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eExtraction of organic pollutants, herbicides, and persistent chemicals from soil matrices.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- COMPLIANCE --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 20px;\"\u003eCompliance and Data Integrity\u003c\/h2\u003e\n\u003cul style=\"margin: 0 0 50px; padding-left: 20px; color: #555; font-size: 14px; line-height: 2;\"\u003e\n\u003cli\u003eCE certified for EU market compliance\u003c\/li\u003e\n\u003cli\u003eFully enclosed fume-hood structure with transparent window for process observation\u003c\/li\u003e\n\u003cli\u003eAnti-permeation flow path design prevents reflux and ensures stable pressure\u003c\/li\u003e\n\u003cli\u003eFree editing of all core extraction parameters for method traceability\u003c\/li\u003e\n\u003cli\u003eCompatible with all major brand SPE cartridges on the market\u003c\/li\u003e\n\u003cli\u003eAutomatic cap removal for immunoaffinity columns without protective fluid loss\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eCommon Questions\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdetails open=\"\" style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eWhich SPE cartridges are compatible? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e-\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003ePrepS supports all major brand SPE cartridges including C18, HLB, and immunoaffinity columns in 1 mL to 20 mL sizes. Good sealing ensures reliable performance across manufacturers.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eCan I run large-volume water samples? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. The optional large-volume loading module supports up to 20 L per channel, making it ideal for trace-level environmental water analysis.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eWhat extraction modes are supported? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eStandard SPE cartridge extraction on all models. PrepS-6 and PrepS-8 additionally support membrane extraction, membrane-column combined extraction, and string-column extraction.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eHow many samples per day? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eUp to 80 samples per batch on PrepS-8. Multichannel parallel processing with automatic needle cleaning between samples means throughput is limited only by your downstream instrument.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eCan it connect to other NWSPEC systems? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. PrepS is designed for combined use with other NWSPEC sample preparation systems such as PrepN and PrepV for seamless end-to-end workflows.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eIs immunoaffinity column supported? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. All PrepS models support immunoaffinity columns with automatic cap removal that preserves protective fluid and does not interrupt the extraction process.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c!-- FOOTER NOTE --\u003e\n\u003cdiv style=\"border-top: 2px solid #000; padding: 30px 0 40px; text-align: center;\"\u003e\n\u003cp style=\"font-size: 16px; font-weight: bold; color: #000; margin: 0 0 8px;\"\u003eCustom method development and application consulting available.\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; color: #888; margin: 0;\"\u003eCompatible with LC-MS\/MS and GC-MS\/MS analytical platforms\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":49125238603995,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/S4-2.png?v=1786433581","url":"https:\/\/nwspec.com\/products\/fully-automated-spe","provider":"NWSPEC","version":"1.0","type":"link"}