{"product_id":"fully-automated-vacuum-parallel-concentrator","title":"Fully Automated Vacuum Parallel Concentrator","description":"\u003cdiv style=\"font-family: Arial,sans-serif; color: #333; line-height: 1.7; max-width: 800px; margin: 0 auto; padding: 0 20px;\"\u003e\n\u003c!-- HEADER --\u003e\n\u003cdiv style=\"border-bottom: 3px solid #000; padding: 40px 0 20px; margin-bottom: 40px;\"\u003e\n\u003ch1 style=\"font-size: 32px; font-weight: 800; color: #000; margin: 0 0 12px; line-height: 1.2;\"\u003eFully Automated Vacuum Parallel Concentrator — PrepV Series\u003c\/h1\u003e\n\u003cp style=\"font-size: 16px; color: #555; margin: 0;\"\u003ePatented vacuum, heating, and shaking technology for rapid solvent evaporation with 100% recovery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 3 HIGHLIGHTS --\u003e\n\u003cdiv style=\"display: flex; gap: 20px; margin-bottom: 50px; flex-wrap: wrap;\"\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e36\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eSamples processed simultaneously\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e100%\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eSolvent recovery via condensation\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1; min-width: 200px; border: 1px solid #000; padding: 20px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 36px; font-weight: 800; color: #000;\"\u003e1 L\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #555; margin-top: 4px;\"\u003eMaximum single-tube volume\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- WHY AUTOMATE --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 20px;\"\u003eWhy Automate Your Vacuum Concentration Workflow\u003c\/h2\u003e\n\u003cp style=\"margin: 0 0 12px; color: #555;\"\u003eManual rotary evaporation is slow and labor-intensive: set vacuum, adjust temperature, monitor each flask, stop before bumping, transfer to vial, and clean glassware. Solvent loss and cross-contamination are constant risks.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 20px; color: #555;\"\u003eParallel manual concentration of multiple samples is nearly impossible. Analysts babysit rotovaps for hours while throughput remains bottlenecked by the number of water baths and fume hoods available.\u003c\/p\u003e\n\u003cdiv style=\"background: #f5f5f5; border-left: 4px solid #000; padding: 16px 20px; margin-bottom: 50px;\"\u003e\n\u003cstrong style=\"color: #000; display: block; margin-bottom: 8px;\"\u003eWith full automation:\u003c\/strong\u003e\n\u003cp style=\"margin: 0; color: #444;\"\u003eLoad tubes. Set vacuum, temperature, and shake parameters. Press start. Collect concentrated samples and recovered solvent. Walk away.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 6 STEPS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eWhat the System Does\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eLoad\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003ePlace concentration tubes into the rack. Supports 9-position (1 L), 25-position (100–250 mL), or 36-position (100 mL) configurations\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eSeal and Vacuum\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eIndividual tube vacuum seal assembly ensures independent pressure control per position. No cross-talk between samples\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eHeat and Shake\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eDouble-layer water bath heating combined with eccentric shaking technology. Shake amplitude adjustable to match sample viscosity and volume\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eCondense and Recover\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eEfficient condensation system (single or double coil) recovers 100% of evaporative solvents into a recovery bottle. Protects lab personnel and environment\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px; margin-bottom: 20px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e5\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eEnd-Point Detection\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eOptional patented optical sensor detects residual volume at 0.5 mL or 1.0 mL per tube. Stops heating and vacuum automatically per channel\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; gap: 16px;\"\u003e\n\u003cdiv style=\"width: 32px; height: 32px; background: #000; color: #fff; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-size: 14px; font-weight: bold; flex-shrink: 0;\"\u003e6\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color: #000; font-size: 15px;\"\u003eCollect\u003c\/strong\u003e\n\u003cp style=\"margin: 2px 0 0; color: #555; font-size: 14px;\"\u003eConcentrated samples remain in detachable chromatography vial tubes. No secondary transfer. Ready for direct LC-MS\/MS or GC-MS\/MS injection\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- KEY FEATURES --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eKey Features\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 50px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000; width: 45%;\"\u003eSample positions\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e9 \/ 25 \/ 36 depending on tube rack configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eTube volume range\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e100 mL to 1 L (9-position); 100–250 mL (25-position); 100 mL (36-position)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eHeating\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eDouble-layer water bath with vacuum tube heating support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eShaking\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eEccentric shaking with adjustable amplitude via nut adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eCondensation\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eSingle-coil or double-coil condensation unit; 100% solvent recovery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eCooling\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eExternal water cooling circulator (recommended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eVacuum\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eIndependent vacuum seal per tube; optional vacuum unit accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eEnd-point detection\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eOptional optical sensor module for 9 \/ 25 \/ 36 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eTouch screen\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eFull-color touchscreen on multi-joint adjustable robotic arm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eAC 100–240 V, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #ddd;\"\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eOperating environment\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003eAmbient to 40 °C, 20–80% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 12px 0; font-weight: bold; color: #000;\"\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd style=\"padding: 12px 0; color: #555;\"\u003e504 × 624 × (240–500) mm (screen arm adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eWhat You Can Test\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdiv style=\"padding: 16px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eEnvironmental Analysis\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eConcentration of water, soil, and sediment extracts for pesticide and pollutant analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eFood and Beverage\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eSolvent removal from food additive, flavor, and contaminant extracts prior to chromatography.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px 0; border-bottom: 1px solid #ddd;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eChemical Industry\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eParallel concentration of reaction mixtures, quality-control samples, and purification fractions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"padding: 16px 0;\"\u003e\n\u003cstrong style=\"color: #000;\"\u003eTesting and Research\u003c\/strong\u003e\n\u003cp style=\"margin: 4px 0 0; color: #555; font-size: 14px;\"\u003eHigh-throughput sample prep for contract labs, government testing centers, and R\u0026amp;D facilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- COMPLIANCE --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 20px;\"\u003eCompliance and Data Integrity\u003c\/h2\u003e\n\u003cul style=\"margin: 0 0 50px; padding-left: 20px; color: #555; font-size: 14px; line-height: 2;\"\u003e\n\u003cli\u003ePatented product design with CE certification\u003c\/li\u003e\n\u003cli\u003e100% evaporative solvent recovery via efficient condensation system\u003c\/li\u003e\n\u003cli\u003eTransparent window and water bath lighting for real-time observation\u003c\/li\u003e\n\u003cli\u003eIndividual tube vacuum seal — add or remove one tube without system shutdown\u003c\/li\u003e\n\u003cli\u003eAdjustable touchscreen angle on multi-joint robotic arm for ergonomic operation\u003c\/li\u003e\n\u003cli\u003eCompatible with detachable chromatography vial tubes — no secondary transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: 800; color: #000; border-bottom: 2px solid #000; padding-bottom: 8px; margin: 0 0 24px;\"\u003eCommon Questions\u003c\/h2\u003e\n\u003cdiv style=\"margin-bottom: 50px;\"\u003e\n\u003cdetails open=\"\" style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eWhat tube sizes are supported? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e-\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003ePrepV supports 100 mL, 150 mL, 200 mL, 250 mL, and 1 L concentration tubes. Both standard Quant tubes and detachable chromatography vial tubes are available. Built-in and external racks match each format.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eHow does the solvent recovery system work? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eAn efficient condensation unit (single or double coil) captures evaporated solvent and channels it into a dedicated recovery bottle. Combined with a water cooling circulator, this achieves near 100% recovery and prevents harmful vapors from entering the lab atmosphere.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eCan I adjust shaking intensity? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. The eccentric shaking amplitude is adjustable via a dedicated nut. Increase amplitude for viscous samples or high-boiling solvents; reduce it for delicate or low-volume samples.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eCan I add or remove tubes during a run? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. The individual tube vacuum seal assembly allows one tube to be added or removed without suspending pressure relief for the entire system. Other samples continue concentrating uninterrupted.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin-bottom: 10px; border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eWhat chiller and vacuum are recommended? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eA water cooling circulator (B-type) and dedicated vacuum unit are available as accessories. These complete the recommended configuration for maximum condensation efficiency and stable vacuum control.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ccc; border-radius: 4px;\"\u003e\n\u003csummary style=\"padding: 14px 18px; font-weight: bold; color: #000; font-size: 14px; cursor: pointer; list-style: none; position: relative;\"\u003eCan it connect to other NWSPEC systems? \u003cspan style=\"position: absolute; right: 18px; top: 50%; transform: translateY(-50%); font-size: 18px; color: #888;\"\u003e+\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 18px 14px; font-size: 14px; color: #555; line-height: 1.7; border-top: 1px solid #eee; margin: 0 18px; padding-top: 12px;\"\u003eYes. PrepV is designed for combined use with other NWSPEC sample preparation systems such as PrepS and PrepN, enabling seamless extraction-to-concentration workflows without manual transfers.\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c!-- FOOTER NOTE --\u003e\n\u003cdiv style=\"border-top: 2px solid #000; padding: 30px 0 40px; text-align: center;\"\u003e\n\u003cp style=\"font-size: 16px; font-weight: bold; color: #000; margin: 0 0 8px;\"\u003eCustom method development and application consulting available.\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; color: #888; margin: 0;\"\u003eCompatible with LC-MS\/MS and GC-MS\/MS analytical platforms\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":49125707972827,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/501dbcb016ae4f0c24e7e9b385e13bfc_f2f54a26-b608-4cfd-8a19-37354d99959d.png?v=1786442565","url":"https:\/\/nwspec.com\/products\/fully-automated-vacuum-parallel-concentrator","provider":"NWSPEC","version":"1.0","type":"link"}