{"product_id":"ram-m20-ram-m30-confocal-raman-microscope","title":"Research Universal Confocal Raman Microscope","description":"\u003c!-- ============================================================\n     NWSPEC Ram-M20 \/ Ram-M30 — Research Universal Confocal Raman Microscope\n     Application-first product guide (real-world scenarios first)\n     ============================================================ --\u003e\n\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; max-width: 900px; margin: 0 auto; color: #111111; line-height: 1.6; font-size: 16px;\"\u003e\n\u003c!-- Header Block --\u003e\n\u003cdiv style=\"border-bottom: 2px solid #e2e8f0; padding-bottom: 14px; margin-bottom: 20px;\"\u003e\n\u003ch2 style=\"font-size: 22px; font-weight: bold; margin: 0 0 8px 0; color: #111827;\"\u003eRam-M20 \/ Ram-M30 Research Universal Confocal Raman Microscope\u003c\/h2\u003e\n\u003cp style=\"margin: 0; color: #4b5563; font-size: 16px;\"\u003eModular confocal Raman platform for multi-technique research labs — materials science, chemistry, biomedicine, geology and cultural heritage — with 200\/300 mm focal length, up to 4 lasers, true pinhole + slit confocal optics and a reserved upgrade path for fluorescence, lifetime, TERS and angle-resolved imaging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Quick-Spec Hero Bar --\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px,1fr)); gap: 12px; margin-bottom: 28px;\"\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; padding: 14px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 12px; font-weight: 600; color: #64748b; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 4px;\"\u003eSpectral Resolution\u003c\/div\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold; color: #0f172a;\"\u003e≤ 0.8 cm⁻¹\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #475569; margin-top: 2px;\"\u003e≤1.0 \/ ≤1.5 cm⁻¹ options\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; padding: 14px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 12px; font-weight: 600; color: #64748b; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 4px;\"\u003eExcitation Lasers\u003c\/div\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold; color: #0f172a;\"\u003eUp to 4 Lasers\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #475569; margin-top: 2px;\"\u003e213–1064 nm auto-switching\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; padding: 14px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 12px; font-weight: 600; color: #64748b; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 4px;\"\u003eSpectral Coverage\u003c\/div\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold; color: #0f172a;\"\u003e50–9700 cm⁻¹\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #475569; margin-top: 2px;\"\u003edetector 200–1100 nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #f8fafc; border: 1px solid #e2e8f0; border-radius: 6px; padding: 14px; text-align: center;\"\u003e\n\u003cdiv style=\"font-size: 12px; font-weight: 600; color: #64748b; text-transform: uppercase; letter-spacing: 0.5px; margin-bottom: 4px;\"\u003eConfocal Optics\u003c\/div\u003e\n\u003cdiv style=\"font-size: 20px; font-weight: bold; color: #0f172a;\"\u003eTrue Pinhole + Slit\u003c\/div\u003e\n\u003cdiv style=\"font-size: 13px; color: #475569; margin-top: 2px;\"\u003e0–2000 µm coaxial control\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Application Scenarios First --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eReal-World Application Scenarios\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 12px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #e5e7eb;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f8fafc; color: #111827;\"\u003e\n\u003cth style=\"padding: 10px 12px; text-align: left; border: 1px solid #e5e7eb; font-weight: 600; width: 26%;\"\u003eScenario\u003c\/th\u003e\n\u003cth style=\"padding: 10px 12px; text-align: left; border: 1px solid #e5e7eb; font-weight: 600; width: 38%;\"\u003eWhat You Are Trying to Do\u003c\/th\u003e\n\u003cth style=\"padding: 10px 12px; text-align: left; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eHow Ram-M20 \/ M30 Solves It\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eMulti-user shared facility\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eServe Raman, fluorescence-ready and future techniques on one instrument without buying new systems.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eModular architecture: sources, spectrometers, detectors and microscope optics combine freely and upgrade later — fluorescence, lifetime, remote probe, TERS and angle-resolved imaging are reserved by design.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eFluorescence-limited biomedical samples\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eGet clean Raman from cells, tissue and drug formulations that swamp 532 nm systems.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eUp to 4 lasers from 213–1064 nm — add 785\/830\/1064 nm NIR excitation to defeat fluorescence while keeping 532 nm for routine work.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003ePharmaceutical polymorph QC\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eDistinguish crystal forms and map API distribution in tablets and powders.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eTrue pinhole + slit confocal isolates pure material; ≤0.8 cm⁻¹ resolution separates close bands; repeatability ±0.1 cm⁻¹ (Si 520.6 cm⁻¹) tracks subtle shifts.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eCultural-heritage pigment analysis\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eIdentify pigments on paintings and ceramics without sampling or damage.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eMicro-confocal sampling with coaxial 0–2000 µm pinhole protects artifacts; color camera and 10×–100× objectives target micro-areas.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eOperando batteries \u0026amp; catalysis\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eFollow electrode and catalyst changes inside working cells.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eReserved functional modules — in-situ reaction cell, electrochemistry kit and remote probe detection — install when the project arrives.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eLow-wavenumber lattice work\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eAccess modes close to the laser line for crystals and 2D materials.\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 12px; border: 1px solid #e5e7eb;\"\u003eUltra-low wavenumber option to ≥±5 cm⁻¹, customizable at order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Why it fits --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eWhy It Fits Your Laboratory\u003c\/h3\u003e\n\u003cp style=\"font-size: 15px; color: #374151; margin: 0;\"\u003eThe Ram-M20 and Ram-M30 are the universal research tier of the NWSPEC Ram-M series: \u003cb\u003eRam-M20\u003c\/b\u003e (200 mm) is the compact everyday workhorse for routine mapping and QC; \u003cb\u003eRam-M30\u003c\/b\u003e (300 mm) balances resolution and throughput for multi-purpose labs; a \u003cb\u003e400 mm custom build\u003c\/b\u003e approaches flagship performance without flagship cost. All share one software platform, one mapping stage and one upgrade path, so accessories and training transfer across your lab.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Build Your Configuration - 3 Decisions --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eBuild Your Configuration — 3 Key Decisions\u003c\/h3\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; background: #f8fafc; padding: 16px; border-radius: 4px; margin-bottom: 14px;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; font-size: 15px; font-weight: bold; color: #111827;\"\u003eDecision 1 — Spectrometer Base: M20 vs. M30 vs. 400 mm Custom\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; background: #f8fafc; border: 1px solid #e5e7eb;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f8fafc; color: #111827;\"\u003e\n\u003cth style=\"padding: 8px 10px; border: 1px solid #e5e7eb; text-align: left;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 8px 10px; border: 1px solid #e5e7eb; text-align: left;\"\u003eFocal Length\u003c\/th\u003e\n\u003cth style=\"padding: 8px 10px; border: 1px solid #e5e7eb; text-align: left;\"\u003eResolution\u003c\/th\u003e\n\u003cth style=\"padding: 8px 10px; border: 1px solid #e5e7eb; text-align: left;\"\u003eRecommended For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eRam-M20\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e200 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e≤0.8 cm⁻¹\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003eRoutine mapping, QC, multi-purpose research\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\"\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003eRam-M30\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e300 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e≤1.0 cm⁻¹\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003eBalanced resolution and throughput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb; font-weight: 600;\"\u003e400 mm custom\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e400 mm\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003e≤0.8 cm⁻¹\u003c\/td\u003e\n\u003ctd style=\"padding: 8px 10px; border: 1px solid #e5e7eb;\"\u003eDemanding research near flagship performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; background: #f8fafc; padding: 16px; border-radius: 4px; margin-bottom: 14px;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; font-size: 15px; font-weight: bold; color: #111827;\"\u003eDecision 2 — Laser Bay (Up to 4 Lasers)\u003c\/h4\u003e\n\u003cp style=\"font-size: 14px; margin: 0 0 8px 0; color: #374151;\"\u003eSelect up to 4 ultra-narrow-linewidth lasers from 213, 248, 257, 355, 405, 488, 532, 633, 785, 830, 850 and 1064 nm (±0.5 nm, RMS stability 0.24%\/4 h, 0.1–500 mW continuously adjustable).\u003c\/p\u003e\n\u003cul style=\"margin: 0; padding-left: 20px; font-size: 14px; color: #4b5563;\"\u003e\n\u003cli\u003e\n\u003cb\u003eMaterials \u0026amp; 2D:\u003c\/b\u003e 532 nm + 633 nm (add 785 nm for fluorescent substrates)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBiomedical \u0026amp; pharma:\u003c\/b\u003e 785\/830 nm (fluorescence suppression) + 532 nm reference\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUV resonance Raman:\u003c\/b\u003e 213\/248\/257\/355 nm deep-UV options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #e2e8f0; background: #f8fafc; padding: 16px; border-radius: 4px; margin-bottom: 14px;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; font-size: 15px; font-weight: bold; color: #111827;\"\u003eDecision 3 — Detector Cooling \u0026amp; Reserved Modules\u003c\/h4\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #374151;\"\u003eChoose TEC-cooled CCD at room temperature, −30, −40 or −70 °C to match your SNR needs. Add reserved extensions at any time: fluorescence spectroscopy, fluorescence lifetime, remote probe detection, TERS and micro angle-resolved imaging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Key Specifications --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; margin-bottom: 12px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #e5e7eb;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eFocal length\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eRam-M20: 200 mm · Ram-M30: 300 mm (400 mm built to order)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\\\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eSpectral resolution\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003e≤ 0.8 \/ 1.0 \/ 1.5 cm⁻¹ options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003e± 0.1 \/ ± 0.2 \/ ± 0.5 cm⁻¹ (Si 520.6 cm⁻¹ Raman band)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\\\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eExcitation lasers\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eUp to 4 paths, 213–1064 nm, ±0.5 nm; stability RMS 0.24 % \/ 4 h; 0.1–500 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eConfocal optics\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eTrue pinhole + slit, 0–2000 µm, both continuously and independently adjustable, coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\\\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eGratings\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eUp to 4 mounted, 150–3600 g\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eTEC-cooled area-array CCD: room temperature \/ −30 \/ −40 \/ −70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\\\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eSpectral range\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003e200–1100 nm \/ 50–9700 cm⁻¹; ultra-low wavenumber ≥ ±5 cm⁻¹ customizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eSignal quality\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eSi 3rd-order peak SNR \u0026gt; 25:1; 4th order observable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\\\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eMicroscope\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003e10× \/ 20× \/ 50× LWD \/ 100× objectives; color camera with on-screen imaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eMapping stage\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eAutomated 3D stage 75 × 50 × 15 mm, 1 µm repeatability, 100 nm minimum step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f9fafb;\\\"\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb; font-weight: 600; width: 35%;\\\"\u003eCalibration\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 12px; border: 1px solid #e5e7eb;\"\u003eIntegrated three-lamp calibration source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- FAQ --\u003e\n\u003cdiv style=\"margin-bottom: 28px;\"\u003e\n\u003ch3 style=\"font-size: 18px; font-weight: bold; color: #111827; border-left: 4px solid #2563eb; padding-left: 10px; margin: 0 0 12px 0;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv style=\"margin-bottom: 12px;\"\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 4px 0; font-weight: bold; color: #111827;\\\"\u003eWhich model do I need — Ram-M20 or Ram-M30?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #4b5563;\\\"\u003eFor routine mapping and QC the M20 is ideal. If your lab mixes resolution-hungry measurements with high throughput — or plans low-wavenumber and upgrade modules — the 300 mm focal length of the M30 is the better long-term choice. Ask us for a configuration recommendation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 12px;\"\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 4px 0; font-weight: bold; color: #111827;\\\"\u003eCan I upgrade the system later instead of buying new?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #4b5563;\\\"\u003eYes. The architecture is modular: additional laser paths, gratings, detectors and functional modules (in-situ cells, electrochemistry, TERS, fluorescence) can be added at any time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin-bottom: 12px;\"\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 4px 0; font-weight: bold; color: #111827;\\\"\u003eWhat is the difference between Ram-M400 and a 400 mm custom Ram-M30?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #4b5563;\\\"\u003eBoth offer 400 mm focal length. Ram-M400 is the dedicated flagship with our highest base specification set; the 400 mm custom Ram-M30 is the configurable modular platform with a lower entry price. We will recommend the better value for your application.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp style=\"font-size: 15px; margin: 0 0 4px 0; font-weight: bold; color: #111827;\\\"\u003eDo you support OEM \/ ODM and private label?\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; margin: 0; color: #4b5563;\\\"\u003eYes — custom focal lengths, laser sets, gratings, software branding and neutral documentation are available for distributors, integrators and instrument brands worldwide. Contact us with your specification and annual volume.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- Quote Callout Box --\u003e\n\u003cdiv style=\"border: 1px solid #cbd5e1; padding: 20px; background: #f8fafc; border-radius: 4px; margin-top: 24px;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px 0; font-size: 16px; font-weight: bold; color: #111827;\\\"\u003eGet a Configuration Recommendation \u0026amp; Quote\u003c\/h4\u003e\n\u003cp style=\"margin: 0 0 10px 0; font-size: 14px; color: #334155; line-height: 1.5;\\\"\u003eTell us your application, laser wavelengths (from 213–1064 nm) and extension modules. NWSPEC will configure your Ram-M20 or Ram-M30 platform and provide a comprehensive quotation. OEM \/ ODM and private-label programs are available for volume customers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":51273175302363,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/Routine_confocal_Raman_microscope.png?v=1795687574","url":"https:\/\/nwspec.com\/products\/ram-m20-ram-m30-confocal-raman-microscope","provider":"NWSPEC","version":"1.0","type":"link"}