{"product_id":"uhplc-system-for-pharma-pesticide-protein-analysis-16-000-psi-lc80","title":"UHPLC System for Pharma, Pesticide \u0026 Protein Analysis | 16,000 psi | LC80","description":"\u003cstyle\u003e\n  .uhplc-order-guide {\n    max-width: 1200px;\n    margin: 0 auto;\n    padding: 40px 20px;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, \"Helvetica Neue\", Arial, sans-serif;\n    color: #1a1a1a;\n    background: #fff;\n  }\n  \n  .uhplc-order-guide h1 {\n    font-size: 38px;\n    font-weight: 700;\n    margin-bottom: 12px;\n    color: #000;\n    line-height: 1.2;\n  }\n  \n  .uhplc-order-guide .subtitle {\n    font-size: 18px;\n    color: #555;\n    margin-bottom: 32px;\n    font-weight: 400;\n  }\n  \n  .uhplc-order-guide .intro-card {\n    background: #000;\n    color: #fff;\n    padding: 28px 32px;\n    margin-bottom: 40px;\n  }\n  \n  .uhplc-order-guide .intro-card h3 {\n    font-size: 14px;\n    text-transform: uppercase;\n    letter-spacing: 1px;\n    margin: 0 0 12px 0;\n    opacity: 0.8;\n  }\n  \n  .uhplc-order-guide .intro-card p {\n    font-size: 16px;\n    line-height: 1.6;\n    margin: 0;\n    opacity: 0.95;\n  }\n  \n  .uhplc-order-guide .section-title {\n    font-size: 24px;\n    font-weight: 700;\n    color: #000;\n    margin: 48px 0 24px 0;\n    padding-bottom: 12px;\n    border-bottom: 2px solid #000;\n  }\n  \n  .uhplc-order-guide .config-grid {\n    display: grid;\n    grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n    gap: 20px;\n    margin-bottom: 40px;\n  }\n  \n  .uhplc-order-guide .config-card {\n    border: 2px solid #e0e0e0;\n    padding: 24px;\n    transition: all 0.2s ease;\n    cursor: pointer;\n  }\n  \n  .uhplc-order-guide .config-card:hover {\n    border-color: #000;\n    transform: translateY(-2px);\n  }\n  \n  .uhplc-order-guide .config-card.recommended {\n    border-color: #000;\n    background: #fafafa;\n  }\n  \n  .uhplc-order-guide .config-card .card-header {\n    display: flex;\n    justify-content: space-between;\n    align-items: flex-start;\n    margin-bottom: 16px;\n  }\n  \n  .uhplc-order-guide .config-card h4 {\n    font-size: 18px;\n    font-weight: 700;\n    margin: 0;\n    color: #000;\n  }\n  \n  .uhplc-order-guide .config-card .badge {\n    background: #000;\n    color: #fff;\n    padding: 4px 10px;\n    font-size: 11px;\n    font-weight: 600;\n    text-transform: uppercase;\n    letter-spacing: 0.5px;\n  }\n  \n  .uhplc-order-guide .config-card .specs {\n    font-size: 14px;\n    color: #555;\n    line-height: 1.6;\n    margin-bottom: 16px;\n  }\n  \n  .uhplc-order-guide .config-card .specs strong {\n    color: #000;\n    font-weight: 600;\n  }\n  \n  .uhplc-order-guide .config-card .mandatory {\n    font-size: 12px;\n    color: #000;\n    margin-bottom: 12px;\n    padding: 8px 12px;\n    background: #f0f0f0;\n    border-left: 3px solid #000;\n  }\n  \n  .uhplc-order-guide .config-card .select-btn {\n    display: inline-block;\n    padding: 10px 24px;\n    background: #fff;\n    border: 2px solid #000;\n    color: #000;\n    font-size: 13px;\n    font-weight: 600;\n    text-transform: uppercase;\n    letter-spacing: 0.5px;\n    cursor: pointer;\n    transition: all 0.2s ease;\n    width: 100%;\n    text-align: center;\n  }\n  \n  .uhplc-order-guide .config-card:hover .select-btn {\n    background: #000;\n    color: #fff;\n  }\n  \n  .uhplc-order-guide .detector-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 24px 0;\n    font-size: 14px;\n  }\n  \n  .uhplc-order-guide .detector-table th {\n    background: #000;\n    color: #fff;\n    padding: 14px 16px;\n    text-align: left;\n    font-weight: 600;\n  }\n  \n  .uhplc-order-guide .detector-table td {\n    padding: 14px 16px;\n    border-bottom: 1px solid #e0e0e0;\n    vertical-align: top;\n  }\n  \n  .uhplc-order-guide .detector-table tr:hover td {\n    background: #fafafa;\n  }\n  \n  .uhplc-order-guide .detector-table .application {\n    font-size: 12px;\n    color: #666;\n    margin-top: 4px;\n  }\n  \n  .uhplc-order-guide .detector-table .mandatory-feature {\n    font-size: 11px;\n    color: #000;\n    background: #f5f5f5;\n    padding: 2px 6px;\n    margin-top: 4px;\n    display: inline-block;\n  }\n  \n  .uhplc-order-guide .option-row {\n    display: flex;\n    align-items: center;\n    padding: 16px 0;\n    border-bottom: 1px solid #e0e0e0;\n  }\n  \n  .uhplc-order-guide .option-row input[type=\"checkbox\"] {\n    width: 20px;\n    height: 20px;\n    margin-right: 16px;\n    accent-color: #000;\n  }\n  \n  .uhplc-order-guide .option-info h4 {\n    font-size: 16px;\n    font-weight: 600;\n    margin: 0 0 4px 0;\n  }\n  \n  .uhplc-order-guide .option-info p {\n    font-size: 13px;\n    color: #666;\n    margin: 0;\n  }\n  \n  .uhplc-order-guide .summary-box {\n    background: #f5f5f5;\n    padding: 24px;\n    margin-top: 40px;\n    border-left: 4px solid #000;\n  }\n  \n  .uhplc-order-guide .summary-box h3 {\n    font-size: 18px;\n    font-weight: 700;\n    margin: 0 0 16px 0;\n  }\n  \n  .uhplc-order-guide .summary-box ul {\n    margin: 0;\n    padding-left: 20px;\n  }\n  \n  .uhplc-order-guide .summary-box li {\n    margin-bottom: 8px;\n    font-size: 14px;\n  }\n  \n  .uhplc-order-guide .cta-section {\n    margin-top: 48px;\n    text-align: center;\n    padding: 40px;\n    background: #000;\n    color: #fff;\n  }\n  \n  .uhplc-order-guide .cta-section h3 {\n    font-size: 24px;\n    font-weight: 700;\n    margin: 0 0 16px 0;\n  }\n  \n  .uhplc-order-guide .cta-btn {\n    display: inline-block;\n    padding: 16px 40px;\n    background: #fff;\n    color: #000;\n    font-size: 14px;\n    font-weight: 700;\n    text-transform: uppercase;\n    letter-spacing: 1px;\n    text-decoration: none;\n    transition: all 0.2s ease;\n  }\n  \n  .uhplc-order-guide .cta-btn:hover {\n    background: #f0f0f0;\n    transform: translateY(-2px);\n  }\n  \n  .uhplc-order-guide .spec-highlight {\n    background: #fafafa;\n    border-left: 3px solid #000;\n    padding: 16px 20px;\n    margin: 20px 0;\n    font-size: 14px;\n  }\n  \n  .uhplc-order-guide .spec-highlight strong {\n    color: #000;\n  }\n  \n  .uhplc-order-guide .compliance-badge {\n    display: inline-block;\n    background: #1a1a1a;\n    color: #fff;\n    padding: 3px 8px;\n    font-size: 10px;\n    font-weight: 600;\n    text-transform: uppercase;\n    letter-spacing: 0.5px;\n    margin-left: 8px;\n  }\n\u003c\/style\u003e\n\n\u003cdiv class=\"uhplc-order-guide\"\u003e\n  \u003ch1\u003eUHPLC System Order Guide\u003c\/h1\u003e\n  \u003cp class=\"subtitle\"\u003eUltra-High Performance Liquid Chromatography for Global Laboratories\u003c\/p\u003e\n  \n  \u003cdiv class=\"intro-card\"\u003e\n    \u003ch3\u003eSystem Overview\u003c\/h3\u003e\n    \u003cp\u003eNext-generation UHPLC system with unified \u003cstrong\u003e16,000 psi (105 MPa \/ 1,050 bar)\u003c\/strong\u003e pressure capability across pump and autosampler. Features \u003cstrong\u003e≤150 μL\u003c\/strong\u003e system delay volume, \u003cstrong\u003e≤0.0005%\u003c\/strong\u003e carryover, and validated \u003cstrong\u003e0.039% RSD\u003c\/strong\u003e retention time reproducibility. Engineered for trace-level analysis of pesticides, veterinary residues, pharmaceutical impurities, antibiotics, and proteins in complex matrices.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \n  \u003cdiv class=\"spec-highlight\"\u003e\n    \u003cstrong\u003eUnified Pressure Architecture:\u003c\/strong\u003e Pump 16,000 psi | Autosampler 16,000 psi | Delay Volume ≤150 μL | Flow Precision ≤0.06% RSD | Carryover ≤0.0005%\n  \u003c\/div\u003e\n  \n  \u003ch2 class=\"section-title\"\u003eStep 1: Select Pump Configuration\u003c\/h2\u003e\n  \u003cdiv class=\"config-grid\"\u003e\n    \u003cdiv class=\"config-card\"\u003e\n      \u003cdiv class=\"card-header\"\u003e\n        \u003ch4\u003eStandard UHPLC Pump\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"mandatory\"\u003e4-Channel Pressure Feedback | Auto-Priming | Compressibility Compensation\u003c\/div\u003e\n      \u003cdiv class=\"specs\"\u003e\n        \u003cstrong\u003eMax Pressure:\u003c\/strong\u003e 16,000 psi (105 MPa \/ 1,050 bar)\u003cbr\u003e\n        \u003cstrong\u003eFlow Range:\u003c\/strong\u003e 0.001–5.00 mL\/min\u003cbr\u003e\n        \u003cstrong\u003eDelay Volume:\u003c\/strong\u003e ≤150 μL\u003cbr\u003e\n        \u003cstrong\u003eGradient:\u003c\/strong\u003e Binary High-Pressure Mixing (A1\/A2, B1\/B2)\u003cbr\u003e\n        \u003cstrong\u003ePrecision:\u003c\/strong\u003e ≤0.06% RSD\u003cbr\u003e\n        \u003cstrong\u003eDegasser:\u003c\/strong\u003e 2-Channel Integrated Vacuum\n      \u003c\/div\u003e\n      \u003cdiv class=\"select-btn\"\u003eSelect Standard\u003c\/div\u003e\n    \u003c\/div\u003e\n    \n    \u003cdiv class=\"config-card recommended\"\u003e\n      \u003cdiv class=\"card-header\"\u003e\n        \u003ch4\u003eAdvanced UHPLC Pump\u003c\/h4\u003e\n        \u003cspan class=\"badge\"\u003eRecommended\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"mandatory\"\u003e4-Channel Pressure Sensors | Auto-Priming | Real-Time Compressibility | Seal Wash Included\u003c\/div\u003e\n      \u003cdiv class=\"specs\"\u003e\n        \u003cstrong\u003eMax Pressure:\u003c\/strong\u003e 16,000 psi (105 MPa \/ 1,050 bar)\u003cbr\u003e\n        \u003cstrong\u003eFlow Range:\u003c\/strong\u003e 0.001–5.00 mL\/min\u003cbr\u003e\n        \u003cstrong\u003eDelay Volume:\u003c\/strong\u003e ≤150 μL\u003cbr\u003e\n        \u003cstrong\u003eSmart Features:\u003c\/strong\u003e Intelligent Weighing Tray | Mobile Phase Monitoring\u003cbr\u003e\n        \u003cstrong\u003eSeal Wash:\u003c\/strong\u003e Included (High-Salt Mobile Phase Compatible)\u003cbr\u003e\n        \u003cstrong\u003eCompensation:\u003c\/strong\u003e Automatic Continuous Real-Time Compressibility\n      \u003c\/div\u003e\n      \u003cdiv class=\"select-btn\"\u003eSelect Advanced\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003ch2 class=\"section-title\"\u003eStep 2: Select Autosampler\u003c\/h2\u003e\n  \u003cdiv class=\"config-grid\"\u003e\n    \u003cdiv class=\"config-card\"\u003e\n      \u003cdiv class=\"card-header\"\u003e\n        \u003ch4\u003eStandard Autosampler\u003c\/h4\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"mandatory\"\u003eNeedle-Loading Non-Destructive Injection | 162-Sample Capacity | Visual Window\u003c\/div\u003e\n      \u003cdiv class=\"specs\"\u003e\n        \u003cstrong\u003eSample Capacity:\u003c\/strong\u003e ≥162 × 2 mL vials or 3 × 96-well microplates\u003cbr\u003e\n        \u003cstrong\u003eInjection Mode:\u003c\/strong\u003e Needle-Loading (Zero Sample Loss)\u003cbr\u003e\n        \u003cstrong\u003eInjection Range:\u003c\/strong\u003e 0.1–30 μL (Expandable)\u003cbr\u003e\n        \u003cstrong\u003ePrecision:\u003c\/strong\u003e ≤0.25% RSD\u003cbr\u003e\n        \u003cstrong\u003eMax Pressure:\u003c\/strong\u003e 16,000 psi (105 MPa \/ 1,050 bar)\u003cbr\u003e\n        \u003cstrong\u003eCarryover:\u003c\/strong\u003e ≤0.0005% (Caffeine, UV)\u003cbr\u003e\n        \u003cstrong\u003eOperation:\u003c\/strong\u003e Touch-Button Auto Door, Auto-Eject Tray\n      \u003c\/div\u003e\n      \u003cdiv class=\"select-btn\"\u003eSelect Standard\u003c\/div\u003e\n    \u003c\/div\u003e\n    \n    \u003cdiv class=\"config-card recommended\"\u003e\n      \u003cdiv class=\"card-header\"\u003e\n        \u003ch4\u003eCooled Autosampler\u003c\/h4\u003e\n        \u003cspan class=\"badge\"\u003eBio\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"mandatory\"\u003e4°C or 20°C Below Ambient Cooling | Visual Window | Auto Door\u003c\/div\u003e\n      \u003cdiv class=\"specs\"\u003e\n        \u003cstrong\u003eSample Capacity:\u003c\/strong\u003e ≥162 × 2 mL vials or 3 × 96-well microplates\u003cbr\u003e\n        \u003cstrong\u003eInjection Mode:\u003c\/strong\u003e Needle-Loading (Zero Sample Loss)\u003cbr\u003e\n        \u003cstrong\u003eTemperature Control:\u003c\/strong\u003e 4°C or 20°C Below Ambient (Whichever Comes First)\u003cbr\u003e\n        \u003cstrong\u003eMax Pressure:\u003c\/strong\u003e 16,000 psi (105 MPa \/ 1,050 bar)\u003cbr\u003e\n        \u003cstrong\u003eCarryover:\u003c\/strong\u003e ≤0.0005%\u003cbr\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e Temperature-Sensitive Biologicals, Proteins, Antibiotics\n      \u003c\/div\u003e\n      \u003cdiv class=\"select-btn\"\u003eSelect Cooled\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003ch2 class=\"section-title\"\u003eStep 3: Select Column Oven\u003c\/h2\u003e\n  \u003cdiv class=\"config-grid\"\u003e\n    \u003cdiv class=\"config-card recommended\"\u003e\n      \u003cdiv class=\"card-header\"\u003e\n        \u003ch4\u003eStandard Column Oven\u003c\/h4\u003e\n        \u003cspan class=\"badge\"\u003eRecommended\u003c\/span\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"mandatory\"\u003e5°C or 15°C Below Ambient to 120°C | 3 × 300mm Column Capacity | 2 Switching Valves\u003c\/div\u003e\n      \u003cdiv class=\"specs\"\u003e\n        \u003cstrong\u003eTemperature Range:\u003c\/strong\u003e 5°C (or 15°C Below Ambient) to 120°C\u003cbr\u003e\n        \u003cstrong\u003eColumn Capacity:\u003c\/strong\u003e 3 × 300 mm or 6 × 100 mm\u003cbr\u003e\n        \u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.5°C\u003cbr\u003e\n        \u003cstrong\u003eStability:\u003c\/strong\u003e ≤±0.3°C\u003cbr\u003e\n        \u003cstrong\u003eValves:\u003c\/strong\u003e 2 Column Switching Valves\u003cbr\u003e\n        \u003cstrong\u003eIncrement:\u003c\/strong\u003e 0.1°C\n      \u003c\/div\u003e\n      \u003cdiv class=\"select-btn\"\u003eSelect Standard\u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003ch2 class=\"section-title\"\u003eStep 4: Select Detector(s)\u003c\/h2\u003e\n  \u003ctable class=\"detector-table\"\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth\u003eDetector\u003c\/th\u003e\n        \u003cth\u003eSpecifications\u003c\/th\u003e\n        \u003cth\u003eKey Features\u003c\/th\u003e\n        \u003cth\u003eSelect\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\n          \u003cstrong\u003ePhotodiode Array (PDA)\u003c\/strong\u003e\n          \u003cdiv class=\"application\"\u003eFull-Spectrum Qualitative \u0026amp; Quantitative\u003c\/div\u003e\n        \u003c\/td\u003e\n        \u003ctd\u003e\n          Wavelength: 190-800 nm\u003cbr\u003e\n          Light Source: Single Deuterium Lamp\u003cbr\u003e\n          Sampling: ≥80 Hz\u003cbr\u003e\n          Noise: ≤2×10⁻⁵ AU\n        \u003c\/td\u003e\n        \u003ctd\u003e\n          \u003cspan class=\"mandatory-feature\"\u003eSingle-Lamp Full Coverage\u003c\/span\u003e\u003cbr\u003e\n          \u003cspan class=\"mandatory-feature\"\u003e10-Step Digital Resolution\u003c\/span\u003e\n        \u003c\/td\u003e\n        \u003ctd\u003e\u003cinput type=\"checkbox\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\n          \u003cstrong\u003eRefractive Index (RID)\u003c\/strong\u003e\n          \u003cdiv class=\"application\"\u003eUniversal Non-Chromophore Detection\u003c\/div\u003e\n        \u003c\/td\u003e\n        \u003ctd\u003e\n          Range: 1.00-1.75 RI\u003cbr\u003e\n          Linearity: 600 μRIU\u003cbr\u003e\n          Sampling: \u0026gt;85 Hz\u003cbr\u003e\n          Noise: ≤2.5 nRIU\n        \u003c\/td\u003e\n        \u003ctd\u003e\n          \u003cspan class=\"mandatory-feature\"\u003e3-Zone Independent Control\u003c\/span\u003e\u003cbr\u003e\n          \u003cspan class=\"mandatory-feature\"\u003eLow Power Mode\u003c\/span\u003e\u003cbr\u003e\n          \u003cspan class=\"mandatory-feature\"\u003eOvertemp + Leak Protection\u003c\/span\u003e\n        \u003c\/td\u003e\n        \u003ctd\u003e\u003cinput type=\"checkbox\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\n          \u003cstrong\u003eFluorescence (FLD)\u003c\/strong\u003e\n          \u003cdiv class=\"application\"\u003eTrace-Level Fluorescent Compounds\u003c\/div\u003e\n        \u003c\/td\u003e\n        \u003ctd\u003e\n          Ex: 200-750 nm\u003cbr\u003e\n          Em: 210-750 nm\u003cbr\u003e\n          Sampling: ≥115 Hz\u003cbr\u003e\n          S\/N: ≥1500 (Water Raman)\n        \u003c\/td\u003e\n        \u003ctd\u003e\n          \u003cspan class=\"mandatory-feature\"\u003e4-Channel Simultaneous\u003c\/span\u003e\u003cbr\u003e\n          \u003cspan class=\"mandatory-feature\"\u003e3D Fluorescence Scanning\u003c\/span\u003e\u003cbr\u003e\n          \u003cspan class=\"mandatory-feature\"\u003eFilter Auto-Calibration\u003c\/span\u003e\u003cbr\u003e\n          \u003cspan class=\"mandatory-feature\"\u003ePMT Normalization\u003c\/span\u003e\n        \u003c\/td\u003e\n        \u003ctd\u003e\u003cinput type=\"checkbox\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003e\n          \u003cstrong\u003eEvaporative Light Scattering (ELSD)\u003c\/strong\u003e\n          \u003cdiv class=\"application\"\u003eNon-UV, Non-Volatile Compounds\u003c\/div\u003e\n        \u003c\/td\u003e\n        \u003ctd\u003e\n          Evaporation: RT-150°C\u003cbr\u003e\n          Nebulization: 35-60°C\u003cbr\u003e\n          Sampling: ≥95 Hz\u003cbr\u003e\n          LOD: ≤0.5 ng (Cholesterol)\n        \u003c\/td\u003e\n        \u003ctd\u003e\n          \u003cspan class=\"mandatory-feature\"\u003e650nm Laser Optional\u003c\/span\u003e\u003cbr\u003e\n          \u003cspan class=\"mandatory-feature\"\u003eHigh-Sensitivity PMT\u003c\/span\u003e\u003cbr\u003e\n          \u003cspan class=\"mandatory-feature\"\u003e1-6 Sensitivity Levels\u003c\/span\u003e\u003cbr\u003e\n          \u003cspan class=\"mandatory-feature\"\u003eLow Power Protection\u003c\/span\u003e\n        \u003c\/td\u003e\n        \u003ctd\u003e\u003cinput type=\"checkbox\"\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n  \n  \u003ch2 class=\"section-title\"\u003eStep 5: Software \u0026amp; Compliance Options\u003c\/h2\u003e\n  \u003cdiv class=\"option-row\"\u003e\n    \u003cinput type=\"checkbox\" id=\"software-suite\"\u003e\n    \u003cdiv class=\"option-info\"\u003e\n      \u003ch4\u003eChromatography Software Suite \u003cspan class=\"compliance-badge\"\u003e21 CFR Part 11\u003c\/span\u003e\n\u003c\/h4\u003e\n      \u003cp\u003eDatabase management | Multi-language interface (EN\/DE\/FR\/ES\/RU) | Audit trail | Real-time equipment monitoring | Automatic delay volume compensation | Consumables lifetime management\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003cdiv class=\"option-row\"\u003e\n    \u003cinput type=\"checkbox\" id=\"seal-wash-opt\"\u003e\n    \u003cdiv class=\"option-info\"\u003e\n      \u003ch4\u003eSeal Wash Kit\u003c\/h4\u003e\n      \u003cp\u003eIncluded with Advanced pump configuration. Extends plunger rod lifetime with high-salt mobile phases\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003cdiv class=\"option-row\"\u003e\n    \u003cinput type=\"checkbox\" id=\"weighing-tray\"\u003e\n    \u003cdiv class=\"option-info\"\u003e\n      \u003ch4\u003eIntelligent Weighing Tray\u003c\/h4\u003e\n      \u003cp\u003eMobile phase consumption monitoring with precision alerts (included with Advanced pump)\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003cdiv class=\"option-row\"\u003e\n    \u003cinput type=\"checkbox\" id=\"column-switching\"\u003e\n    \u003cdiv class=\"option-info\"\u003e\n      \u003ch4\u003eColumn Switching Valve Kit\u003c\/h4\u003e\n      \u003cp\u003e2-position valves enabling multi-dimensional LC and method development screening\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003cdiv class=\"option-row\"\u003e\n    \u003cinput type=\"checkbox\" id=\"validation-docs\"\u003e\n    \u003cdiv class=\"option-info\"\u003e\n      \u003ch4\u003eIQ\/OQ\/PQ Validation Documentation \u003cspan class=\"compliance-badge\"\u003eGMP\/GLP\u003c\/span\u003e\n\u003c\/h4\u003e\n      \u003cp\u003eInstallation, operational, and performance qualification protocols for regulated environments\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n  \n  \u003cdiv class=\"summary-box\"\u003e\n    \u003ch3\u003eSystem Highlights\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eUnified 16,000 psi Pressure Architecture:\u003c\/strong\u003e Both pump and autosampler rated to 16,000 psi (105 MPa) for seamless sub-2μm separations\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMinimal Delay Volume:\u003c\/strong\u003e ≤150 μL system volume for rapid gradient response\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eNon-Destructive Injection:\u003c\/strong\u003e Needle-loading technology with zero sample loss\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eSuperior Precision:\u003c\/strong\u003e ≤0.06% RSD flow, ≤0.25% RSD injection, 0.039% RSD retention time\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eZero Carryover:\u003c\/strong\u003e ≤0.0005% (caffeine, UV detection)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eIntelligent Control:\u003c\/strong\u003e Auto-priming, real-time compressibility compensation, delay volume auto-compensation\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eGlobal Compliance:\u003c\/strong\u003e 21 CFR Part 11, GMP\/GLP ready, multi-language software\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eBiological Sample Protection:\u003c\/strong\u003e Cooled autosampler maintains sample integrity\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \n  \u003cdiv class=\"cta-section\"\u003e\n    \u003ch3\u003eRequest a Quote\u003c\/h3\u003e\n    \u003cp\u003eConfigure your UHPLC system with unified 16,000 psi pressure architecture and receive comprehensive pricing within 24 hours\u003c\/p\u003e\n    \u003ca href=\"#\" class=\"cta-btn\"\u003eGet Quote\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"NWSPEC","offers":[{"title":"Default Title","offer_id":47300713480411,"sku":"LC80","price":80000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0766\/1722\/0315\/files\/UHPLC_pic_94b295a3-d812-4270-bd05-4a8baff8dbaa.png?v=1764216031","url":"https:\/\/nwspec.com\/products\/uhplc-system-for-pharma-pesticide-protein-analysis-16-000-psi-lc80","provider":"NWSPEC","version":"1.0","type":"link"}