OEM Spectrometer Sensor

Spectrometer Sensor OEM & Custom Solutions

— Leading spectrometer manufacturing in bulk

NWSPEC (Xiong’an) Co., Ltd. · Xiongan Pilot Free Trade Zone, Hebei, China

As a global leader in spectrometer technology, NWSPEC offers a comprehensive range of cutting-edge spectroscopy solutions, powered by a world-class technical team of experts in optics, mechanics, electronics, and software development. Our spectrometers are designed to meet the growing demands of environmental inspections, in-line inspections, biomedical diagnostics, and beyond.

Universal Compatibility Our accessories and sensor platforms are compatible with most major spectrometer brands. Custom integration support is available for OEM projects.

OEM Spectrometer Sensor Platforms

All models support cross-platform secondary development packages (SDK). Customers can complete rapid development using provided function libraries for Windows, Android, Linux, and WinCE. Click any model to view the product page.

Model Detector Spectral Range Resolution (FWHM) Key Features
SR20 Hamamatsu CMOS, 2048 px, 14×200 μm 200–1100 nm Up to 1.00 nm Miniature
SMA905 · USB 2.0 / RS232 / RS485
80×63×34 mm · 320 g
SR30 Hamamatsu CMOS, 1024 px, 25×500 μm 200–1100 nm Up to 0.80 nm High-Speed
0.8 ms/frame · 10 MHz output
128×72×40 mm · 500 g
SR40 Hamamatsu CMOS, 2048 px, 14×200 μm 200–1100 nm Up to 0.80 nm Low Drift & Low Noise
0.1 px/°C drift · <50 RMS noise · Auto zero
128×72×40 mm · 500 g
SR50 Hamamatsu CMOS, 2048 px, 14×200 μm 350–1100 nm Up to 1.20 nm Color / CIE
High chromaticity stability · Rugged industrial
128×72×40 mm · 500 g
SR58 Hamamatsu CMOS, 2048 px, 14×200 μm 200–1100 nm Up to 0.80 nm Ethernet Network
Up to 100 devices via switch · USB / RS232
127.4×98×40 mm · 800 g
SR60 Hamamatsu CMOS, 2048 px, 14×200 μm 200–1100 nm Up to 0.10 nm Ultra-High Resolution
Synchronized multi-channel
157×110×50 mm · 1150 g
SR63 Hamamatsu CCD area array, 2048 px, 14×14×64 μm 200–1100 nm Up to 0.10 nm Back-Thinned CCD
Two-stage cooling · 20°C below ambient
182×110×50 mm · 1600 g
SR65 Back-illuminated CCD, 1024 px, 24×24×58 μm 200–1100 nm Up to 0.50 nm Deep-Cooled CCD
Scientific grade · 40°C below ambient
182×110×50 mm · 1600 g
SR68
256 px
InGaAs, 256 px, 100×100 μm 900–1700 /
1430–1700 /
900–2500 nm
3.20 / 1.41 / 6.37 nm NIR InGaAs
Two-stage cooled
182×110×50 mm · 1500 g
SR68
512 px
InGaAs, 512 px 900–1700 /
1430–1700 /
900–2500 nm
NIR InGaAs
Two-stage cooled
SR68
1024 px
InGaAs, 1024 px 900–1700 nm /
1430–1700 nm /
900–2500 nm
NIR InGaAs
Two-stage cooled

Common Technical Specifications

Optical Design f/4, Symmetrical Crossed Czerny-Turner
Stray Light <0.1%
Linearity >99% – >99.8%
A/D Converter 16-bit, lossless
Integration Time 0.1 ms – 90 s (model dependent)
Communication USB 2.0, RS232, RS485 (Ethernet on SR58)
Power Consumption 300 mA @ 5V DC (450 mA / 4 A for cooled models)
Operating Systems Windows, Android, Linux, WinCE
Fiber Connector SMA905, 0.22 NA
Mounting 3-direction standard installation holes

OEM Customization Options

Wavelength Range

200–1100 nm (UV-Vis-NIR) or 900–2500 nm (NIR). Combine multiple SR60 units for extended coverage. Custom gratings available.

Slit Sizes

30, 40, 50, 60, 70, 100, 150, 200 μm. Resolution scales with slit width per published tables. Custom slits on request.

Detectors

CMOS linear array (1024 / 2048 px), CCD area array (back-thinned, cooled), InGaAs (256 / 512 / 1024 px). Hamamatsu sensors standard.

Communication Interface

USB 2.0, RS232, RS485 standard. Ethernet (SR58 platform). 16-pin expansion interface with external trigger support.

Cooling Options

Passive (SR20–SR60). Two-stage TEC: 20°C below ambient (SR63) or 40°C below ambient (SR65). 4 A @ 5V DC for deep-cooled.

Higher-Order Filter

Optional long-pass filter add-on available on all models for suppression of higher-order diffraction effects.

OEM Branding

Private-label enclosure designs, custom firmware boot screens, and specialized packaging available for volume orders.

Integration Support

Full SDK with C/C++, C#, Python, LabVIEW, and MATLAB bindings. Custom protocol development available.

Typical OEM Applications

Color Science & CIE Measurement
Wafer Inspection & Film Thickness
LED Spectral Analysis
Raman Spectroscopy
LIBS / Plasma Emission
Gas Absorption Detection
Environmental Monitoring
Water Quality Analysis
Biomedical & Life Science
Food & Agriculture
Material Composition Analysis
Laser Wavelength Detection
Online Component Analysis
Chemical Concentration
Fiber Optic Transmittance
Teaching & Research

OEM Spectrometer Sensor Accessories

Complete accessory ecosystem for integration with NWSPEC spectrometer sensor platforms. All accessories use standard SMA905 interface unless noted. Compatible with most major spectrometer brands.

Light Sources
Model Product Wavelength Key Specification Key Feature
SR-T1 Tungsten Halogen Light Source 350–2500 nm 12V / 10W or 100W · Stability 0.3% · >3000 h (10W) / >1000 h (100W) SMA905
SR-T2 High-Power Tungsten Light Source 350–2500 nm 12V / 100W · Stability 0.3% · >1000 h · Warm-up 5 min High Power · SMA905
SR-UV1 UV Standard Light Source 190–520 nm 30W · >1000 h · Warm-up 20 min UV-Only · SMA905
SR-DT1 Deuterium-Tungsten Integrated Light Source 190–1100 nm D2 + W · Stability 0.3% (30 min) · SMA905 Dual-Source · SMA905
SR-DT2 NIR-Enhanced Broadband Light Source 300–2500 nm D2 + W · Stability 0.14–0.16% · 2000 h · Warm-up 20 min NIR Enhanced · SMA905
SR-DT3 NIR-Enhanced Broadband Light Source (3-Lamp) 300–2500 nm D2 + dual W · Stability 0.14–0.22% · 2000 h · Warm-up 20 min Triple-Lamp · SMA905
SR-HG1 Hg-Ar Wavelength Calibration Lamp 200–1100 nm NIST-traceable · Accuracy 0.1 nm · 5W · 1000 h Calibration · SMA905
SR-HG2 Mercury Wavelength Calibration Light Source 190–920 nm 8 certified Hg lines · 3W · DC12V · SMA905 8-Line Cal · SMA905
SR-X1 Xenon Flash Lamp 200–850 nm 2W / 5W · <100 Hz · Stability 2.5% · 10&sup9; pulses Flash · SMA905
SR-X2 Xenon Pulsed Light Source 185–2000 nm 2W · DC12V · 10&sup9; pulses · SMA905 Broadband Pulsed · SMA905
SR-L1 LED Composite Light Source 270–950 nm 0.2–10W · Stability 0.1% · >100,000 h Long Life · SMA905
NW-LEDW-3W White LED Light Source 410–700 nm TEC-cooled · Stability 0.31% · 20,000 h · USB control Visible LED · SMA905
NW1000 LED-Tungsten Combined Light Source 395–700 nm 395 nm + 430 nm LED + tungsten · 0–100% adjustable · 5V/2A LED+W Combo · SMA905
SR-C1 Portable Calibration Source NIST-traceable · DC supply · Calibration tools included Field Cal · SMA905
Sampling Accessories
Model Product Application Interface Key Feature
SR-S1 Cuvette Holder (1 cm) Liquid absorption SMA905 Standard 10 mm
SR-S2 Cuvette Holder (5 cm) Long-path liquid SMA905 5 cm Path
SR-S3 Flow Cell Holder Online monitoring SMA905 Flow-Through
SR-A1 Customized Quartz Optical Fiber Reflection / Transmission / Remote sensing SMA905 / FC / TA / TB 190–2500 nm
SR-D1 Diffuse Reflection Accessory Solid / Powder SMA905 Integrating Sphere
Calibration Standards
Model Product Specification Use
SR-R1 Reflectance Standard PTFE / Spectralon · >99% (250–2500 nm) Reflectance Cal
SR-R2 Hg-Ar Wavelength Calibration Lamp NIST-traceable · Multiple certified peaks · 200–1100 nm λ Verification
SR-F1 Fluorescence Reference Standard Quartz cuvette · Certified reference material Fluorescence Cal
Integrating Spheres & Accessories

PTFE / Spectralon coated integrating spheres for uniform light source systems, camera calibration, sensor characterization, and display testing. Custom port configurations available.

Model Diameter / Type Ports Coating Reflectance Use Case
IS-50 50 mm 3 × SMA905 PTFE / Spectralon >95% Compact setups
IS-100 100 mm 4 × SMA905 PTFE / Spectralon >97% General purpose
IS-150 150 mm 4 × SMA905 PTFE / Spectralon >97% Medium samples
IS-200 200 mm 4 × SMA905 PTFE / Spectralon >98% Large samples
IS-250 250 mm 4 × SMA905 PTFE / Spectralon >98% Extended area
IS-300 300 mm 4 × SMA905 PTFE / Spectralon >98% Camera cal / Display
IS-500 500 mm 4 × SMA905 PTFE / Spectralon >98% Large sensor testing
IS-1m 1000 mm 4 × SMA905 PTFE / Spectralon >98% Large sample measurement
SR-IS Uniform Light Source Sphere Custom PTFE / Spectralon >95% Uniform illumination / Camera cal
SR-PS1 Programmable Power Supply N/A N/A N/A Constant current for IS light sources · 0–2.5A / 0–25V
SR-C Series — Optical Intensity Control Modules

Motorized optical control modules for precision intensity management in uniform light source integrating sphere systems. Software-integrated control. Modules may be used in combination or independently.

Product Model Specification Function Control
Motorized Variable Attenuator SR-C-ATT OD 0.5 / 1.0 / 1.5 / 2.0 (4-position filter wheel) Stepped Coarse Adjustment Software-integrated · SMA905
Motorized Iris Diaphragm SR-C-IRIS Max aperture 25 mm · Continuously variable Fine Continuous Trimming Software-integrated · SMA905
Electronic Optical Shutter SR-C-SHT Aperture 25 mm · Response <5 ms Rapid On/Off Switching Software-integrated · SMA905

Customization & OEM Services

Custom Optics

Custom gratings, filters, and optical path designs for specialized wavelength ranges and resolution requirements.

Mechanical Customization

Custom enclosure dimensions, mounting configurations, and port layouts for seamless system integration.

Firmware & Software

Custom communication protocols, boot branding, and specialized SDK functions for embedded deployments.

Volume Production

Scaled manufacturing with consistent unit-to-unit performance, QC documentation, and traceable calibration.

Request OEM Quotation

Contact our sales team with your target wavelength range, resolution, detector type, and estimated volume.
We deliver laboratory-grade performance at competitive prices.

Tel: +86 189-6516-4839 · Xiongan Pilot Free Trade Zone, Hebei, China

© 2026 NWSPEC (Xiong’an) Co., Ltd. All rights reserved.

Contact form

Track Order

Please enter your tracking number below:

Frequently Asked Questions

How can I contact you?

Feel free to call us T+86 189-6516-4839
or email  sales@nwspec.com to:

• Place an order
• Ask for a quote
• Or if you have any other questions

You will always get a live person here at NWSPEC; never an automated system! 

We are open from 6:00AM - 7:00PM Eastern Time, Monday - Friday. 

Where can I find application notes?

If you have any questions regarding the application notes, or can't find the one you are looking for, please contact Sales at sales@nwspec.com



Do you have instructional manuals for your instruments to download?

Yes, we have instructional manuals for our instruments. They can be found on https://nwspec.com/pages/resource .

If you don't see the one you are looking for, please contact: sales@nwspec.com