Skip to product information
1 of 4

NWSPEC

FT-IR Gas Analyzer

FT-IR Gas Analyzer

IR850 Mobile FT-IR Gas Analyzer

Portable multi-gas monitoring for fixed pollution sources. 200+ customized gases. Global compliance.

One Portable System. 200+ Gases. Real-Time Compliance Anywhere.

The IR850 replaces multiple analyzers and complex sampling trains with one mobile FT-IR system that travels to your stack and measures everything on-site — from inorganics to VOCs to greenhouse gases — with certified accuracy for regulatory reporting.

What Problem Are You Solving?

The Old Way
Multiple Instruments, Lab Delays, Compliance Risk
  • Collect grab samples, send to lab, wait days for results
  • Deploy multiple portable analyzers for different gas classes
  • Miss emission spikes during batch sampling intervals
  • Complex RATA testing with separate reference methods
  • Add new gas requirements? Buy new hardware
The IR850 Way
All-in-One Portable Analysis, Immediate Results
  • Complete mobile lab: analyzer, heated sampling, power, computer in one case
  • 200+ gases in one scan: inorganics, organics, VOCs, greenhouse gases
  • Real-time continuous monitoring: 5 scans/second, no gaps
  • Built-in RATA compliance: meets EPA Method 320, HJ 1240-2021
  • New gas requirements? Software update — no hardware changes

Global Regulatory Compliance

International Standards

  • EPA Method 320: Vapor phase organic/inorganic emissions by FT-IR (USA)
  • EN 15267-3: MCERTS certification for automated monitoring systems (EU)
  • ISO 10396: Automated monitoring of stationary source emissions
  • ASTM D6348: FT-IR for determination of gaseous compounds
  • US EPA 40 CFR Part 60/75: CEMS compliance for power generation

China HJ Standards

  • HJ 919-2017: Ambient air VOCs by portable FT-IR
  • HJ 920-2017: Emergency monitoring of inorganic gases
  • HJ 1011-2018: VOC component monitoring technical requirements
  • HJ 1240-2021: SO₂, NO, NO₂, CO, CO₂ in fixed source emissions
  • HJ 1330-2023: NH₃ and HCl in fixed source emissions

Why Select the IR850?

True Portability, Real Performance

Not a benchtop analyzer in a cart — the IR850 is engineered for field deployment. Complete system in one transport case: heated sampling probe (≥180°C), 5m+ heated lines, lithium power (≥24V 55Ah), mobile workstation (i7/32G/1T), and printer. Set up at any stack in minutes, not hours.

200+ Gases, One Scan, Zero Compromise

From inorganics (SO₂, NOₓ, CO, CO₂, NH₃, HCl, HF, HCN) to VOCs (benzene, toluene, xylene, formaldehyde, chloroform) to greenhouse gases (N₂O, CH₄). No need to choose which gases to monitor — measure all simultaneously with certified ranges from ppm to percent. Custom gas configurations available.

Corrosive Environment Immunity

High-temperature acid gases (HCl, HF, SO₂) and abrasive dust destroy ordinary analyzers. The IR850's anti-corrosion coatings on all gas-contact surfaces, heated sample path (≥180°C), and three-stage filtration (0.5-5μm) ensure reliability in coal-fired power, cement, and waste incineration.

Future-Proof Investment

New emission regulations adding new gas requirements? Simply update the spectral library. The 500-5000 cm⁻¹ range captures every infrared-active compound. Add new gases to analysis without hardware changes, recalibration, or factory service visits. Protect your investment for decades.

Global Language Support

Multi-language software interface adaptable to regional requirements. Localized reporting formats for EPA (USA), EN (EU), HJ (China), or custom standards. One-click help files connect directly to service engineers for rapid technical support anywhere in the world.

From Stack to Report in Minutes

Automated pressure and temperature compensation. Built-in interference correction for complex gas matrices. Dry/wet concentration auto-conversion. Excel-compatible export for immediate report generation. Trend graphs, hourly/daily averages, and spectrum replay for complete audit trails.

Why FTIR Wins for Portable Emissions Monitoring

Traditional Portable Methods

  • Electrochemical sensors: Limited to 3-6 gases, cross-interference errors, frequent calibration drift, short sensor life
  • NDIR analyzers: One detector per gas, cannot measure VOCs, limited dynamic range
  • GC-MS portable: Batch analysis (5-30 min cycles), consumables (carrier gas, columns), complex maintenance
  • Lab sampling: Grab samples miss transient events, transport contamination risk, days for results
VS

IR850 Mobile FT-IR

  • 200+ gases simultaneously: Inorganics + VOCs in one scan, no compromise on coverage
  • Continuous real-time: 5 scans/second, capture every startup, upset, and shutdown event
  • Self-contained: No carrier gas, no consumables, no external power needed (battery operation)
  • Field-rugged: Heated sampling prevents condensation, corrosion coatings resist acid gases

Where Does the IR850 Excel?

Coal-Fired Power & Combustion

Monitor SO₂, NO, NO₂, CO, CO₂ for emissions compliance. Track NH₃ slip from SCR/SNCR denitrification systems. Measure N₂O greenhouse gas emissions.

Why IR850: High moisture, SO₂, and NOₓ in flue gas? Heated sample path and corrosion resistance handle aggressive coal combustion emissions.

Waste Incineration & WtE

Acid gas monitoring: HCl, HF, SO₂. Dioxin precursor detection: benzene, chlorobenzene, chloroform. Complete combustion verification with CO, CO₂, O₂.

Why IR850: Corrosive, high-particulate environment with fluctuating moisture. Triple filtration and acid-resistant coatings protect the analyzer.

Cement & Steel Production

Kiln emission optimization with NOₓ, SO₂, CO. Alternative fuel (AF) combustion monitoring. Sinter plant and coke oven gas analysis.

Why IR850: Abrasive dust and high temperatures that clog and damage other portable analyzers. Designed for industrial harshness.

Chemical & Petrochemical

VOC leak detection: BTX, olefins, aldehydes, ketones. Process safety: HCN, phosgene, aniline. Flare gas composition and combustion efficiency.

Why IR850: Complex organic mixtures with overlapping spectra. High resolution (1 cm⁻¹ option) deconvolves interfering compounds.

Emergency & Environmental Monitoring

Rapid deployment for accident investigation. Ambient air toxic gas monitoring. Fenceline monitoring around industrial facilities.

Why IR850: Portable power (lithium battery), rapid setup, and immediate broad-spectrum analysis for unknown contamination events.

Compliance Testing & RATA

Relative Accuracy Test Audits (RATA) for CEMS validation. Stack testing for permit compliance. Method 320 equivalency demonstrations.

Why IR850: Certified measurement uncertainty meets EPA and international requirements. Documented interference-free operation for regulatory defensibility.

200+ Customizable Gas Components

Factory-Calibrated & Customizable

The IR850 is delivered with factory calibration for 50+ priority gases, with capacity for 200+ total compounds. Custom gas configurations tailored to your specific regulatory requirements and process monitoring needs. Add new gases via software update without hardware modifications.

Inorganic Gases
  • SO₂, NO, NO₂, CO, CO₂
  • NH₃, HCl, HF, HCN
  • N₂O, O₂, H₂O
  • CS₂, SF₆, NF₃
Light Hydrocarbons
  • Methane, Ethane, Propane
  • Ethylene, Acetylene
  • Propylene, Butane
  • Cyclohexane, n-Hexane
Aromatic VOCs
  • Benzene, Toluene, Xylenes
  • Ethylbenzene, Styrene
  • Chlorobenzene, Nitrobenzene
  • Aniline, Phenol
Oxygenated Organics
  • Formaldehyde, Acetaldehyde
  • Acetone, Methanol, Ethanol
  • Acetic acid, Acetic anhydride
  • Methyl acetate, Ethyl acetate
Chlorinated Compounds
  • Dichloromethane, Chloroform
  • Carbon tetrachloride
  • Trichloroethylene, Perchloroethylene
  • Vinyl chloride, Chloroethane
Sulfur & Nitrogen Compounds
  • Ethanethiol, Methanethiol
  • Dimethyl sulfide, DMDS
  • Trimethylamine, Dimethylamine
  • Acrylonitrile, Nitrobenzene
Ethers & Ketones
  • Diethyl ether
  • Methyl ethyl ketone
  • Acetophenone
  • Furfuryl alcohol
Specialty Compounds
  • Phosgene (COCl₂)
  • Perfluoropropane
  • Bromoethane
  • Custom compounds on request

Note: Standard configuration includes 50+ quantitative gases with certified ranges. Extended library covers 200+ compounds with semi-quantitative capability. Custom gas ranges and additional compounds available upon request.

Complete Mobile Laboratory — Standard Configuration

IR850 Analyzer Host Portable FT-IR with DTGS detector, 500-5000 cm⁻¹
Heated Sampling System ≥180°C probe (1m), 5m + 1m heated lines, triple filtration
Mobile Workstation i7/32GB/1TB/14" 2.5K touchscreen, multi-language software
Power System 2× lithium batteries (24V 55Ah, 1500W rated, 5000W peak)
Flue Gas Pretreatment Semiconductor cooling, 0.1μm filtration, phosphoric acid titration
Consumables & Accessories Metal filters (6pcs), transport case, portable printer
Spectral Libraries 50+ quantitative + 200+ qualitative/semi-quantitative
Documentation Factory calibration certificate, compliance manual

Deploy Complete Emissions Monitoring Anywhere

One system. 200+ gases. Global compliance. From stack to report in minutes — not days.

Mobile/WhatsApp: +86 18965164839 | sales@nwspec.com
Regular price $110,000.00 USD
Regular price Sale price $110,000.00 USD
Save Liquid error (snippets/price line 136): divided by 0% Sold out
Shipping calculated at checkout.

View full details
Your cart
Product Product subtotal Quantity Price Product subtotal
FT-IR Gas Analyzer
FT-IR Gas Analyzer
$110,000.00/ea
$0.00
$110,000.00/ea $0.00

GC Accessories

Frequently Asked Questions

How can I contact you?

Feel free to call us T+86 189-6516-4839
or email  sales@nwspec.com to:

• Place an order
• Ask for a quote
• Or if you have any other questions

You will always get a live person here at NWSPEC; never an automated system! 

We are open from 6:00AM - 7:00PM Eastern Time, Monday - Friday. 

Where can I find application notes?

If you have any questions regarding the application notes, or can't find the one you are looking for, please contact Sales at sales@nwspec.com



Do you have instructional manuals for your instruments to download?

Yes, we have instructional manuals for our instruments. They can be found on https://nwspec.com/pages/resource .

If you don't see the one you are looking for, please contact: sales@nwspec.com



Contact form

Track Order

Please enter your tracking number below: