1
/
of
1
NWSPEC
HPLC8000 System
HPLC8000 System
Regular price
$0.00 USD
Regular price
Sale price
$0.00 USD
Unit price
/
per
Couldn't load pickup availability
Description
The LC-8000 is a smart, modular HPLC system designed for high-performance gradient separations. Combining a precision binary pump, variable wavelength detector, and an intelligent system controller, this system ensures stability, durability, and simplicity in operation—ideal for routine and advanced applications.
Features
Infusion pump unit: Four-element low-pressure infusion pump
- Maximum pressure resistance: 6000 psi (40Mpa)
- Flow rate range: 0.001-10,000 mL/min (increment 0.001mL/min)
- Flow accuracy: ≤0.06% RSD(ASTM)
- Flow accuracy: ±0.2%
- Pressure pulsation: ≤1%
- Gradient accuracy: ±0.5%
- Gradient repeatability: ≤0.1%
- Online cleaning of plungers: Standard configuration, high/medium/low speed
- Channel volume: Four-channel degassing function, 480 μ L/channel
- Detector: Ultraviolet-visible detector
- Wavelength range: 190-800 nm
- Light sources: deuterium lamp, tungsten lamp
- Spectral bandwidth: 8 nm
- Wavelength accuracy: ±1 nm
- Noise: ±0.35×10-5 AU (ASTM)
- Drift: 1×10-4 AU/Hr
- Wavelength accuracy: 0.2 nm
- Linear range: >2.5AU (ASTM)
- Maximum sampling rate: 100Hz
- Pressure resistance of the flow cell: 1200PSI
- Flow cell aperture: 10mm
- Minimum detectable concentration: 4×10-9 g/mL
Sampler: Automatic sampler
- Injection mode: Full-loop injection/Partial injection/micro-liter carrier injection
- Quantitative loop volume: Standard configuration is 100 μL
- Injection repeatability: Full-loop injection: RSD≤0.3%; Partial injection: RSD≤0.5%; micro-liter carryover injection: RSD≤1%
- Sample capacity: 2 standard 48-position sample bottle racks, 1.5mL injection bottles (standard configuration)
- (96-well plate and 384-well plate are optional)
- Cross-contamination: < 0.005%
- Linearity: 0.9999
- Maximum pressure resistance: 6000psi (customizable)
Column oven
- Temperature control range: Room temperature +5℃-70℃
- Temperature accuracy: ±1.0℃
- Temperature stability: ±0.1℃
- Column capacity: 1 250mm chromatographic column (1 10mm guard column can be added)
Chromatographic column
Standard configuration: C8,250×4.6mm,5um
Chromatography workstation
- Regulatory applicability: Complies with FDA 21 CFR Part11/GMP/GLP standards;
- Ease of use: The graphical monitoring interface enables you to keep track of the device status at any time, making it simple and easy to use.
- Data Processing: Powerful data processing capabilities, providing multiple integration functions and calculation methods;
- Rich functions: Automatic peak width, automatic threshold algorithm, adaptive data collection, and automatic algorithm adjustment to achieve the best integration effect;
- User Management: It features a powerful and comprehensive user management function, allowing for the setting of access permissions for convenient management. Different usage permissions can be set according to actual needs.