Skip to product information
1 of 1

NWSPEC

Fully Automated Solid Phase Extraction System (PrepS Series)

Fully Automated Solid Phase Extraction System (PrepS Series)

Fully Automated SPE System — PrepS Series

Automated conditioning, sample loading, washing, blow-drying, and elution with independent multichannel control.

2 / 4 / 6 / 8
Independent channels by model
20–80
Extraction columns per batch
20 L
Maximum sample volume with optional module

Why Automate Your SPE Workflow

Manual solid phase extraction requires repetitive conditioning, sample loading, washing, drying, elution, and collection. Every manual step adds variability and occupies skilled laboratory personnel.

The PrepS Series automates the complete SPE workflow while providing independent channel operation, editable method parameters, and an enclosed transparent chamber for process observation.

With full automation:

Load cartridges and samples, select the method, and start the run. The system completes conditioning, loading, washing, blow-drying, elution, and collection with walkaway unattended operation.

What the System Does

1
Condition

Automated SPE cartridge conditioning with editable method parameters.

2
Load

Small-sample loading is standard. The optional large-volume loading module supports sample volumes up to 20 L.

3
Wash

Programmable washing with eight reagent channels. The anti-backflow flow path helps prevent reflux and supports stable pressure.

4
Blow-Dry

Automated nitrogen blow-drying with editable pressure and time settings.

5
Elute and Concentrate

Automated elution and automatic quantitative concentration at 1, 3, 6, 10, 12, or 20 mL.

6
Collect

Model-specific collection racks support 10–50 mL tubes on PrepS 2 / 4 / 6 and 10–35 mL tubes on PrepS 8.

PrepS Model Comparison

On smaller screens, swipe horizontally to compare models.

Technical parameter PrepS 2 PrepS 4 PrepS 6 PrepS 8
Number of channels 2 4 6 8
Maximum extraction columns 20 40 60 80
Maximum sample volume 20 L 20 L 20 L 20 L
Automatic quantitative concentration 1 / 3 / 6 / 10 / 12 / 20 mL 1 / 3 / 6 / 10 / 12 / 20 mL 1 / 3 / 6 / 10 / 12 / 20 mL 1 / 3 / 6 / 10 / 12 / 20 mL
Collection tube volume 10–50 mL 10–50 mL 10–50 mL 10–35 mL
Large-volume module Supported (optional module) Supported (optional module) Supported (optional module) Supported (optional module)
Immunoaffinity column Supported Supported Supported Supported
String module / membrane extraction Not listed Not listed Supported Supported
Reagent channels 8 8 8 8
Touchscreen Angle adjustable Angle adjustable Angle adjustable Angle adjustable
Maximum inlet pressure 0.7 MPa (100 psi) 0.7 MPa (100 psi) 0.7 MPa (100 psi) 0.7 MPa (100 psi)
Power supply AC 100–240 V, 50/60 Hz AC 100–240 V, 50/60 Hz AC 100–240 V, 50/60 Hz AC 100–240 V, 50/60 Hz
Overall power 100 W 120 W 130 W 140 W
Gas supply High-purity nitrogen / inert gas High-purity nitrogen / inert gas High-purity nitrogen / inert gas High-purity nitrogen / inert gas
Operating environment Ambient to 40 °C, 20–80% RH Ambient to 40 °C, 20–80% RH Ambient to 40 °C, 20–80% RH Ambient to 40 °C, 20–80% RH
Noise 50 dB 50 dB 50 dB 50 dB
Dimensions (L × W × H) 473 × 600 × 731 mm 593 × 600 × 731 mm 773 × 600 × 731 mm 773 × 600 × 731 mm
Machine weight ~72 kg ~90 kg ~110 kg ~115 kg
Flow path PTFE standard; PEEK/metal optional PTFE standard; PEEK/metal optional PTFE standard; PEEK/metal optional PTFE standard; PEEK/metal optional
Certification CE CE CE CE

Large-volume loading (up to 20 L) is supported on every model as an optional module. String-column and membrane-extraction options apply to PrepS 6 and PrepS 8.

Order Guide

1. Select Model and Extraction Format

Model Collection rack options Cartridge / piston configuration Advanced extraction options
PrepS 2 16 × 125 mm tube rack; 50 mL quantitative concentration-tube rack 1, 3, 6, 10, 12, or 20 mL SPE column rack with cartridge-specific piston assembly Not listed
PrepS 4 16 × 125 mm tube rack; 50 mL quantitative concentration-tube rack 1, 3, 6, 10, 12, or 20 mL SPE column rack with cartridge-specific piston assembly Not listed
PrepS 6 16 × 125 mm tube rack; 50 mL quantitative concentration-tube rack 1, 3, 6, 10, 12, or 20 mL SPE column rack with cartridge-specific piston assembly String-column racks; 47 mm membrane or membrane-and-column modules; universal collection rack
PrepS 8 16 × 125 mm or 20 × 150 mm tube racks 1, 3, 6, 10, 12, or 20 mL SPE column rack with cartridge-specific piston assembly String-column racks; 47 mm membrane or membrane-and-column modules; universal collection rack

2. Select Consumables and Method Accessories

Consumable group Available formats
SPE cartridges C18 and HLB; 1, 3, 6, 10, 12, or 20 mL
Collection tubes 16 × 75, 16 × 100, 16 × 125, or 20 × 150 mm
Quantitative concentration tube 50 mL with 0.5 / 1.0 mL tail tube
PrepS 6 / PrepS 8 string-column racks 1, 3, 6, 10, or 12 mL
PrepS 6 / PrepS 8 membrane format 47 mm membrane extraction; combined membrane-and-column extraction

3. Complete the Operating System

Model-specific main unit and operation software; waste-solvent filtration and small-sample loading modules; SPE column rack and cartridge-specific piston assemblies; collection rack and height block; optional large-sample loading module for volumes up to 20 L; high-purity nitrogen or other suitable inert gas supply; one-year host warranty.

Recommended Starting Points

Compact Routine SPE — PrepS 2

Two channels and up to 20 columns per batch. Select cartridge rack, piston assemblies, and collection racks required by the method.

General-Purpose Laboratory — PrepS 4

Four channels and up to 40 columns per batch. Use 16 × 125 mm collection tubes or 50 mL quantitative concentration tubes; add large-volume loading when needed.

Multi-Method Laboratory — PrepS 6

Six channels and up to 60 columns per batch, with string-column and 47 mm membrane-extraction options.

Highest Channel Count — PrepS 8

Eight channels and up to 80 columns per batch. Confirm the 10–35 mL collection range and select 16 × 125 mm or 20 × 150 mm tube racks.

Typical Applications

Water and Environmental Samples

Automated SPE extraction, cleanup, and concentration workflows for surface, ground, and drinking water testing.

Food and Beverage

Pesticide residue, veterinary drug, and contaminant cleanup with application-matched cartridge formats.

Biological and Clinical Samples

Serum, plasma, and urine sample preparation with independent multichannel processing to prevent cross-contamination.

Soil and Pharmaceutical Analysis

Flexible cartridge, membrane, and collection formats for trace target enrichment and matrix removal.

Compliance and System Features

  • CE certified for laboratory equipment compliance
  • Transparent automatic door and enclosed chamber for real-time process observation
  • Independent multichannel sampling, needle cleaning, and collection to prevent cross-contamination
  • Anti-backflow flow path design to help prevent reflux and maintain stable pressure
  • Editable extraction parameters and eight reagent channels
  • PTFE flow path as standard, with PEEK or metal optional
  • Immunoaffinity column support across all PrepS models

Common Questions

Which SPE cartridges and formats are available? -
The ordering range lists C18 and HLB cartridges in 1, 3, 6, 10, 12, and 20 mL formats. Select the SPE column rack and cartridge-specific piston assembly to match your laboratory method.
Can I run large-volume water samples? +
Yes. Large-volume loading is supported on every PrepS model as an optional module, handling sample volumes up to 20 L.
What extraction modes are supported? +
Standard SPE cartridge extraction is available across the entire series. PrepS 6 and PrepS 8 additionally support string-column extraction, 47 mm membrane extraction, and combined membrane-and-column extraction.
How many extraction columns can be processed per batch? +
PrepS 2, PrepS 4, PrepS 6, and PrepS 8 support maximum batch capacities of 20, 40, 60, and 80 extraction columns respectively. Daily throughput depends on your specific method run time.
Can PrepS be combined with other NWSPEC systems? +
Yes. PrepS pairs seamlessly with NWSPEC PrepN automated nitrogen evaporators or PrepV parallel vacuum evaporators for complete sample extraction, cleanup, and concentration.
Are immunoaffinity columns supported? +
Yes. Immunoaffinity column support is standard on PrepS 2, PrepS 4, PrepS 6, and PrepS 8. Select the matching column rack and accessories during configuration.

Custom method development and application consulting available.

Compatible with LC-MS/MS and GC-MS/MS analytical platforms

View full details
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

Frequently Asked Questions

How can I contact you?

Feel free to call us T+86 189-6516-4839
or email  sales@nwspec.com to:

• Place an order
• Ask for a quote
• Or if you have any other questions

You will always get a live person here at NWSPEC; never an automated system! 

We are open from 6:00AM - 7:00PM Eastern Time, Monday - Friday. 

Where can I find application notes?

If you have any questions regarding the application notes, or can't find the one you are looking for, please contact Sales at sales@nwspec.com



Do you have instructional manuals for your instruments to download?

Yes, we have instructional manuals for our instruments. They can be found on https://nwspec.com/pages/resource .

If you don't see the one you are looking for, please contact: sales@nwspec.com



Contact form

Track Order

Please enter your tracking number below: