Skip to product information
1 of 1

NWSPEC

ICP-10 ICP-OES Spectrometer | Multi-Element Analysis System

ICP-10 ICP-OES Spectrometer | Multi-Element Analysis System

ICP-10 Spectrometer

Multi-Element Analysis System — Configuration & Selection Guide

15 Elements
Per Minute
2-6 Min
Per Sample
7-16 pm
Resolution
ppb Detection
Limits

Why ICP-10

Dual Analysis Modes

Choose between 2-minute rapid screening or 6-minute comprehensive analysis. Full-spectrum direct reading capability delivers complete elemental profiles in a single run.

Compact Integration

Smaller footprint than conventional ICP systems while maintaining 1-meter optical path. Optimized integration design maximizes laboratory space efficiency.

Configurable Optics

Four holographic grating options (2400-4320 lines/mm) let you optimize resolution versus range. Match the instrument to your element requirements, not the other way around.

Environmental Protection

New inflation device for optical chamber prevents moisture damage to precision components. High corrosion-resistant materials ensure long-term stability in demanding environments.

Select Your Configuration

Configuration Wavelength Range Resolution Best For
ICP-10-2400 160 – 800 nm 16 pm
  • Full spectrum coverage including K, Na
  • Environmental monitoring (alkali metals)
  • Food safety applications
ICP-10-3600 160 – 530 nm 9 pm
  • Metal smelting analysis
  • Mineral analysis (no alkali needs)
  • Enhanced resolution for transition metals
ICP-10-4320 160 – 442.5 nm 7 pm
  • Maximum resolution requirements
  • Complex geological matrices
  • Research and method development
Resolution Selection Principle Higher grating line density improves resolution but narrows wavelength coverage. ICP-10 lets you configure this trade-off precisely: 4320 lines/mm delivers 7 pm resolution for line-rich spectra, while 2400 lines/mm provides full 160-800 nm coverage for comprehensive screening.

Three-Step Selection Guide

1

Define Your Element Requirements

Do you need Alkali Metals (K, Na) or Long-Wave Elements?

If YES → Select ICP-10-2400 (160-800 nm). These elements emit beyond 530 nm and require full-spectrum coverage.

If NO (transition metals only: Fe, Cu, Mn, Cr, Ni, Zn) → Proceed to Step 2.

2

Assess Matrix Complexity

Simple matrices (aqueous solutions, clean minerals) → ICP-10-3600 (9 pm resolution) provides optimal performance.

Complex matrices (heavy industrial samples, rare earth mixtures, high spectral interference) → ICP-10-4320 (7 pm resolution) for maximum separation capability.

3

Select Sample Introduction Kit

KIT-AQUEOUS — Standard solutions, environmental water, food digests. General-purpose concentric nebulizer.

KIT-HIGH-SOLIDS — Mineral digests, metallurgical samples with high dissolved solids. Enhanced tolerance design.

KIT-ORGANIC — Organic solvents, oil analysis, chemical industry samples. Cooled spray chamber and specialized nebulizer.

Recommended Configuration

ICP-10-3600 + KIT-AQUEOUS

Optimized for general industrial and environmental laboratories. The 160-530 nm range covers all common metallic elements (Fe, Cu, Mn, Cr, Ni, Zn, Pb, Cd) with 9 pm resolution sufficient for most regulatory compliance testing. 2-minute rapid analysis mode supports high sample throughput for routine monitoring.

Application-Specific Recommendations

Environmental Monitoring

ICP-10-2400 + KIT-AQUEOUS

Full spectrum coverage for EPA methods requiring alkali metal detection (Na, K in water). 16 pm resolution adequate for diluted environmental matrices. Rapid 2-minute screening for high-volume monitoring stations.

Metal Smelting & Alloys

ICP-10-3600 + KIT-HIGH-SOLIDS

Enhanced resolution for precise alloy composition verification. High-solids kit handles concentrated acid digests. Wide dynamic range covers major constituents to trace impurities simultaneously.

Mineral Analysis

ICP-10-4320 + KIT-HIGH-SOLIDS

Maximum 7 pm resolution for complex geological matrices with line-rich spectra. Handles rare earth elements and refractory minerals with superior spectral separation.

Food Safety & Agriculture

ICP-10-2400 + KIT-AQUEOUS

Full spectrum for nutritional labeling (Na, K, Ca, Mg) and toxic metal screening (Pb, Cd, As). Automated control reduces operator variability for compliance testing.

Technical Specifications Summary

Parameter Specification Benefit
Analysis Speed 15 elements/minute; 2 or 6 min/sample Rapid screening or comprehensive analysis modes
Optical System 1-m Czerny-Turner, argon purged, thermostated High resolution with thermal stability
Grating Options 2400 / 3600 / 4320 lines/mm holographic Configurable resolution: 7-16 pm
Wavelength Precision ±0.03 nm indication, ≤0.003 nm reproducibility Accurate peak location for reliable quantification
Detector Photomultiplier Tube (PMT), single channel Proven sensitivity for trace analysis
RF Generator 40.68 MHz, 4000-5500 W, vacuum tube Stable plasma generation for all matrices
Stability Short-term ≤1.5% RSD, Long-term ≤2.0% RSD Consistent performance over extended runs
Sensitivity ppb level detection (e.g., Mn ≤0.002 mg/L) Trace element capability for regulatory limits
Dimensions 150 × 50 × 107 cm (W×D×H), 235 kg Compact footprint for laboratory efficiency
Software Windows 7/10/11 compatible, automated control Modern OS support with intelligent operation
Automated Operation Advantage ICP-10 features integrated intelligent control that automatically adjusts gas flows, RF power, and sample introduction parameters. This reduces manual intervention, improves reproducibility between operators, and enables less experienced staff to perform high-quality analyses.

Configuration Codes

Base Model Grating Code Kit Code Full Example
ICP-10 -2400 / -3600 / -4320 + KIT-AQUEOUS ICP-10-3600+KIT-AQUEOUS
ICP-10 -2400 / -3600 / -4320 + KIT-HIGH-SOLIDS ICP-10-3600+KIT-HIGH-SOLIDS
ICP-10 -2400 / -3600 / -4320 + KIT-ORGANIC ICP-10-2400+KIT-ORGANIC

Configure Your ICP-10

Contact our applications team with your sample types and regulatory requirements. We'll recommend the optimal grating and sample kit configuration for your analytical workflow.

Request Configuration Support

View full details
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

Frequently Asked Questions

How can I contact you?

Feel free to call us T+86 189-6516-4839
or email  sales@nwspec.com to:

• Place an order
• Ask for a quote
• Or if you have any other questions

You will always get a live person here at NWSPEC; never an automated system! 

We are open from 6:00AM - 7:00PM Eastern Time, Monday - Friday. 

Where can I find application notes?

If you have any questions regarding the application notes, or can't find the one you are looking for, please contact Sales at sales@nwspec.com



Do you have instructional manuals for your instruments to download?

Yes, we have instructional manuals for our instruments. They can be found on https://nwspec.com/pages/resource .

If you don't see the one you are looking for, please contact: sales@nwspec.com



Contact form

Track Order