Skip to product information
1 of 2

NWSPEC

Hyperspectral Fluorescence Microscope

Hyperspectral Fluorescence Microscope

RM-10-F Series — Hyperspectral Fluorescence Imaging

RM-10-F Hyperspectral Fluorescence Microscope

High-Speed Spectral Unmixing & Quantitative Multi-Target Phenotyping

The RM-10-F Series integrates a full 400–1000 nm transmission-grating imaging spectrometer with research-grade fluorescence microscopy. Every pixel acquires its complete optical spectrum at <2.3 nm resolution, eliminating emission filter limits and crosstalk while removing tissue autofluorescence quantitatively.

400–1000 nm
Spectral Range
<2.3 nm
Resolution (F/2.4)
≥300
Spectral Bands
72 fps
Full-Spectrum Rate
<1 μm
Spatial Resolution
16-bit
sCMOS Dynamic Range
1 Key Application Scenarios

Designed to resolve severe spectral overlap and autofluorescence challenges

Immuno-Oncology & Pathology
Multiplexed Tumor Microenvironment Phenotyping
Simultaneously detect and quantify 7+ fluorescent markers on a single formalin-fixed tissue section. Mathematical spectral unmixing separates emission spectra with overlapping peaks, enabling detailed spatial profiling of immune checkpoints, T-cells, and tumor margins.
Key Capability: Crosstalk-free 7+ channel unmixing
Recommended Setup: RM-10-FX Automated System with Plan-Apochromat Optics
Histology & Biopsy
Tissue Autofluorescence Elimination & Margin Analysis
Endogenous collagen, elastin, and fixation artifacts produce strong broadband background autofluorescence that obscures weak fluorophores. The RM-10-F isolates and subtracts autofluorescence signatures pixel by pixel, delivering high signal-to-noise detection of low-expression targets.
Key Capability: Quantitative background subtraction
Recommended Setup: RM-10-FM or RM-10-FX with TE-Cooled sCMOS Core
Cell Biology
Multi-Target Fluorescent Protein & Organelle Co-Localization
Differentiate overlapping fluorescent proteins (e.g., GFP, YFP, CFP, and mCherry) and quantum dots in live or fixed cell cultures. Full spectral recording allows retrospective reconstruction of arbitrary virtual emission channels without re-staining or re-imaging.
Key Capability: Post-acquisition virtual channel reconstruction
Recommended Setup: RM-10-FM Upright Biological Microscope
High-Throughput Screening
Automated Whole-Slide Scanning & Drug Discovery
Equipped with a 120-slide automated sample chamber, intelligent autofocus, and motorized channel switching, the system delivers high-throughput continuous screening for drug safety, target binding, and multi-marker tissue microarrays (TMA).
Key Capability: 120-slide smart chamber & unattended auto-focus
Recommended Setup: RM-10-FX with Assist Cameras & Automated Stage
Materials & Nanotechnology
Quantum Dots, Metasurfaces & Microplastics
Analyze spatial spectral shifts in luminescent nanomaterials, carbon dots, 2D semiconductors, and microplastic particulates. Sub-micron spatial resolution paired with <2.3 nm spectral precision tracks local surface plasmon resonance (LSPR) and nanoscale emission shifts.
Key Capability: Sub-micron spatial & 300+ band spectral mapping
Recommended Setup: RM-10-FM / FX with High-Magnification Objectives
Forensic Science
Forensic Document Examination & Trace Evidence
Non-destructive identification of questioned documents, altered inks, and trace biological fluids on fluorescent or patterned textiles. High-resolution continuous hyperspectral cubes distinguish identical-color inks via subtle spectral reflectance and fluorescence differences.
Key Capability: Non-destructive chemical contrast discrimination
Recommended Setup: RM-10-FM with Flexible Manual Stage
2 Select System Configuration

Choose between flexible manual research and unattended high-throughput automation

Configuration Model SKU Hardware Specifications Best For
Standard Research Configuration RM-10-FM Upright biological microscope, manual focus, 118 × 76 mm stage with 4-slide holder, 7-channel manual fluorescence switching Research labs, core facilities, routine multi-target cell and tissue imaging
Automated High-Throughput Configuration RM-10-FX Research-grade optics, intelligent autofocus, 120-slide smart sample chamber, motorized channel switching, dual RGB + grayscale assist cameras High-throughput pathology, tissue microarrays (TMA), clinical trials, and drug screening
3 Select Objective Set & Optical Package

Research-grade infinity-corrected optics engineered for chromatic accuracy

Optics Package Included Objectives & Specifications System Match
Plan-Achromatic Set 4×, 10×, 20×, 40×, 50×; field number F.N 23, 25, or 26.5; <1 μm spatial resolution RM-10-FM (Standard)
Plan-Apochromatic Set 4×, 10×, 20×, 40×, 60×; field number F.N 25 or 26.5; superior chromatic aberration correction across 400–1000 nm RM-10-FX (Automated)
4 Technical Specifications Reference

Performance benchmarks of the shared 400–1000 nm hyperspectral optical core

Spectral Range 400–1000 nm continuous spectrum per pixel
Spectral Resolution Better than 2.3 nm (F/2.4 aperture)
Detector Technology TE-cooled sCMOS sensor, 16-bit dynamic range, 4×4 binning recommended
Spatial Resolution & Bands 512 spatial pixels per line; ≥300 spectral bands; spatial resolution <1 μm
Frame Rate 72 fps full-spectrum acquisition
Fluorescence Channels 7 discrete channels; manual switching (FM) / motorized switching (FX)
Illumination System 6-position reflected fluorescence illuminator; 12V / 100W halogen transmitted illumination
Sample Handling & Focus Manual stage with 4-slide holder (FM) / Intelligent autofocus with 120-slide chamber (FX)
5 Frequently Asked Questions

Common questions regarding hyperspectral unmixing and sample workflows

How does the system eliminate spectral overlap between multiple fluorophores?
Traditional fluorescence microscopy relies on bandpass optical filters that suffer from bleed-through when emission spectra overlap. The RM-10-F measures the complete 400–1000 nm spectrum for each pixel. Dedicated unmixing algorithms mathematically deconvolute overlapping fluorophores and endogenous autofluorescence without filter limitations.
Can autofluorescence be completely removed from formalin-fixed tissue?
Yes. Tissue autofluorescence exhibits a broad, continuous spectral profile distinct from sharp fluorophore peaks. The software treats autofluorescence as an independent component, subtracting it quantitatively to uncover faint immunohistochemical targets.
Can virtual channels and image views be adjusted after data acquisition?
Yes. Because the entire spectral data cube is saved, researchers can reconstruct custom pseudo-color channels, change emission windows, or add new reference spectra at any time without re-staining or re-exposing samples.
When should a laboratory choose RM-10-FX over RM-10-FM?
Choose the RM-10-FM for manual academic research and smaller slide sets. Choose the RM-10-FX when automated throughput is essential: its 120-slide smart carousel, motorized switching, and intelligent autofocus enable overnight, unattended batch scanning.
Customized Spectral Analysis Workflows: NWSPEC analytical specialists calibrate fluorophore reference libraries and spectral unmixing models to your specific fluorochrome panel and tissue preparation prior to delivery.

Request an Application-Specific Technical Quotation

Describe your fluorophore panel, sample types, and daily slide throughput. Our optical instrumentation team will configure the optimal objective set, stage automation, and provide a formal institutional quote.

Request Quotation

View full details
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

Frequently Asked Questions

How can I contact you?

Feel free to call us T+86 189-6516-4839
or email  sales@nwspec.com to:

• Place an order
• Ask for a quote
• Or if you have any other questions

You will always get a live person here at NWSPEC; never an automated system! 

We are open from 6:00AM - 7:00PM Eastern Time, Monday - Friday. 

Where can I find application notes?

If you have any questions regarding the application notes, or can't find the one you are looking for, please contact Sales at sales@nwspec.com



Do you have instructional manuals for your instruments to download?

Yes, we have instructional manuals for our instruments. They can be found on https://nwspec.com/pages/resource .

If you don't see the one you are looking for, please contact: sales@nwspec.com



Contact form

Track Order