Skip to product information
1 of 3

NWSPEC

NIR10 Near Infrared Spectrometer (700-2500 nm) | NWSPEC

NIR10 Near Infrared Spectrometer (700-2500 nm) | NWSPEC

NIR10 Near Infrared Spectrometer

High-Performance Grating NIR Analyzer with Integrating Sphere | 700–2500 nm

Industry Applications & Use Cases

Engineered for rapid at-line process control, raw-material intake screening, and QA/QC laboratory analysis across diverse industries:

🌾

Animal Feed & Milling

Target Samples: Raw grain meals (soybean, corn, DDGS) and compound feeds.
Operational Value: Rapid gatekeeping at raw-material intake and real-time batch release to prevent off-spec production and optimize formulation costs.

🐄

Forage & Dairy Livestock

Target Samples: Silage, alfalfa, fresh forage, hay, and Total Mixed Ration (TMR).
Operational Value: Non-destructive nutritional evaluation and digestibility profiling to support precise dairy herd ration formulation and harvest timing.

🐾

Pet Food Manufacturing

Target Samples: Extruded dry kibble, slurries, and specialty meat meals.
Operational Value: Real-time monitoring of fat coating uniformity and core nutrient levels to ensure regulatory label guarantee and batch-to-batch consistency.

🌽

Grain & Flour Processing

Target Samples: Whole kernel wheat, corn, oilseeds, and milled flours.
Operational Value: Fast intake silo binning by protein/moisture grades and optimal flour stream blending without time-consuming wet chemistry.

🧬

Seed Breeding & Agronomy

Target Samples: Single seeds and bulk seed lots (canola, wheat, corn, soybeans).
Operational Value: High-throughput, non-destructive genetic trait screening preserving 100% seed viability for subsequent replanting.

🍺

Brewing & Fermentation

Target Samples: Malting barley, wort, fermentation broth, distillates, and wine.
Operational Value: In-process tracking of fermentation kinetics, attenuation, and alcohol accumulation for consistent beverage flavor profiles.

🌿

Tobacco Processing

Target Samples: Green leaf, cured whole leaf, threshed strips, and cut rag.
Operational Value: Automated grading and accurate chemical ratio monitoring (sugar/nicotine) across threshing and secondary processing lines.

🍬

Sugar & Sweeteners

Target Samples: Cane/beet juices, syrups, massecuite, and refined crystalline sugar.
Operational Value: Continuous purity and polarization monitoring from cane intake to crystallization with zero clarifying chemicals.

🌱

Natural Products & Botanicals

Target Samples: Herbal powders, dried botanical extracts, and natural oils.
Operational Value: Rapid screening for active botanical markers and qualitative discrimination against counterfeit or adulterated raw materials.

🌍

Soil & Organic Fertilizers

Target Samples: Agricultural soils, compost, and organic fertilizer granules.
Operational Value: High-throughput fertility profiling and organic carbon quantification for precision agriculture and soil carbon credits.

🧪

Polymers & Chemical QA/QC

Target Samples: Resins, polyols, polymers, and liquid chemical intermediates.
Operational Value: Fast identity verification and hydroxyl/acid number tracking to control polymerization reactions and incoming raw material purity.

🔬

R&D & Chemometrics

Target Samples: Diverse liquid, solid, and powder research matrices.
Operational Value: Robust chemometric modeling (PLS/DPLS), inter-instrument model transfer studies, and direct reference-method correlation.

Key Performance Features

  • Full NIR Spectral Range (700–2500 nm / 14,000–4,000 cm⁻¹): Covers fundamental overtones and combination vibrational bands for C-H, N-H, O-H, and S-H functional groups.
  • High-Speed Multi-Parameter Testing: Delivers simultaneous quantitative analysis for all key constituents in under 60 seconds per sample.
  • Integrating Sphere Diffuse Reflectance: Engineered with a motorized rotating sample stage and large illumination beam spot for representative, non-destructive sampling of heterogeneous materials.
  • Thermally Stabilized Front-End Optics: Optical chamber isolates environmental temperature fluctuations to eliminate thermal drift and ensure long-term repeatability.
  • NIST-Traceable Automatic Calibration: Features integrated PTFE standard tiles and polystyrene reference filters for automated zero-baseline adjustment and continuous wavelength verification.
  • Seamless Inter-Instrument Model Transfer: High optical consistency across manufacturing lots allows direct sharing and deployment of chemometric calibration models without expensive retraining.
  • Versatile Sampling Cup Ecosystem: Accommodates standard powder/granule cups, oversized cups for coarse forage/pellets, and specialized liquid/paste cuvettes.
  • Intuitive Software & Audit Trail: One-click operation interface with multi-level role-based access control, electronic signatures, and tamper-proof audit trail logs.
  • Comprehensive Chemometrics Suite: Supports quantitative calibration modeling (PLS, Local PLS) and qualitative discriminant classification (DPLS) with continuous validation routines.
  • Compact, Industrial-Grade Benchtop Chassis: Space-saving footprint (365 × 295 × 157 mm, 18 kg) designed for demanding QA/QC laboratory benches and at-line plant environments.

Advanced Modeling & Calibration Capabilities

  • Multiple Regression Algorithms in One Platform: Full-spectrum PLS, Local PLS (LPLS), PCR, MLR, and ANN/SVM hybrid engines — automatically select the best algorithm per analyte to maximize accuracy across moisture, protein, fat, fiber, and trace components.
  • Qualitative Discrimination Models (DPLS / SIMCA-Style): Build one-class and multi-class classifiers for raw material identity verification, origin discrimination, adulteration screening, and pass/fail raw-material intake control.
  • Built-In Spectral Preprocessing Toolkit: One-click SNV, MSC, detrending, baseline offset, Savitzky–Golay smoothing (1st/2nd derivative), Norris gap derivatives, and wavelet denoising to remove particle-size and scattering effects on unground samples.
  • Robust Model Validation Workflows: Automatic K-fold cross-validation, blind external validation sets, and live performance reports — RMSEC, RMSEP, R², bias, slope, SECV, and outlier diagnostics (Mahalanobis distance, spectral residual F-test).
  • Inter-Instrument Model Transfer (Slope/Bias + DS): Built-in standardization routines (slope/bias correction, direct standardization) plus factory-matched optics let calibration models deploy across multiple NIR10 units with minimal recalibration cost.
  • Calibration Library Ready-to-Use: Pre-developed starter models for feed, grain, flour, oilseed, forage, pet food, and tobacco — from day one, users get results while refining local models with their own reference data.
  • Outlier & Drift Auto-Monitoring: Real-time spectral qualification flags abnormal scans, instrument drift, or unexpected samples before they contaminate results or calibration databases.
  • Audit-Ready Model Lifecycle Management: Version-controlled model files, electronic signatures, change history, and locked production models — compliant with GLP, ISO 12099, and GMP data-integrity expectations.

Measured Parameters Matrix by Industry

Comprehensive list of constituents and quality indicators measurable simultaneously within 60 seconds:

Industry / Application Core Quantitative Parameters Specialized & Quality Indices
Animal Feed & Milling Moisture, Crude Protein, Crude Fat, Crude Fiber, Total Starch, Ash, Total Sugars ADF, NDF, Amino Acids (Lysine, Methionine, Threonine), Salt (NaCl), Ca, P, Urease Activity, Pepsin Digestibility, Gross Energy
Forage, Silage & Dairy TMR Dry Matter (DM), Crude Protein (CP), Crude Fat, Ash, Starch ADF, NDF, Lignin (ADL), Organic Acids (Lactic, Acetic, Butyric), NH₃-N, 24h/48h IVDMD, NDFD, RFV, RFQ
Pet Food Manufacturing Moisture, Crude Protein, Crude Fat, Crude Fiber, Ash, Starch Fatty Acid Profile (Omega-3 / Omega-6, EPA/DHA), Peroxide Value, Acid Value, Dextrose Equivalence, Kibble Density Correlation
Grain, Flour & Oilseeds Moisture, Protein (as-is & 12.5% mb), Oil Content, Ash, Starch Wet/Dry Gluten, Gluten Index, Hagberg Falling Number, Zeleny Index, Oleic/Linoleic Ratio, Free Fatty Acids (FFA), Iodine Value
Seed Breeding & Agronomy Protein, Oil Content, Starch, Moisture Glucosinolates (Canola), Gossypol (Cottonseed), Kernel Hardness, Single-Seed Trait Screening, Thousand-Kernel Weight Proxy
Brewing, Wine & Fermentation Alcohol by Volume (ABV), Extract, Original Gravity, Moisture, Total Protein Diastatic Power, α-Amylase, β-Glucan, Kolbach Index, Attenuation, Residual Sugars, Total Acidity, Esters, Polyphenols, Free SO₂
Tobacco Processing Moisture, Total Sugars, Reducing Sugars, Nicotine, Total Nitrogen Potassium (K), Chloride (Cl), Sugar/Nicotine Ratio, Petroleum Ether Extract, Filling Value, Qualitative Curing Grade
Sugar, Starch & Sweeteners Brix, Polarity (Pol), Purity, Moisture, Total Starch Reducing Sugars, Dextran, Color Value, Sucrose/Glucose/Fructose Ratios, Starch Lipids, Whiteness
Herbal Extracts & Botanicals Moisture, Total Extractives, Ash Active Marker Content (Polyphenols, Flavonoids, Alkaloids, Essential Oils), Adulterant Screening & Origin Discrimination
Soil & Organic Fertilizers Soil Organic Matter (SOM), Total Nitrogen, Moisture C/N Ratio, Available N-P-K Indices, Humic Acid Content, Compost Maturity & Stability
Polymers & Chemical QA/QC Hydroxyl Number (OHV), Acid Value, Iodine Value, Moisture Monomer Content, Residual Solvent, Antioxidant Additive Levels, Copolymer Ratio, Density/Viscosity Correlation
R&D & Chemometrics Full Raw Spectral Data Export (700–2500 nm in JCAMP-DX / CSV) Custom PLS/LPLS/SVM Method Development, Inter-Instrument Calibration Transfer, Wet Chemistry Correlation (Kjeldahl, Soxhlet, HPLC)

Technical Specifications

Model NIR10
Optical System Scanning grating spectrometer with integrating sphere diffuse reflectance
Wavelength Range 700–2500 nm (14,000–4,000 cm⁻¹)
Spectral Bandwidth 12 nm (nominal)
Wavelength Accuracy < 0.05 nm
Wavelength Repeatability < 0.005 nm
Stray Light ≤ 0.1%
Photometric Noise < 20 µAU (RMS)
Measurement Time < 60 seconds (user-configurable)
Light Source Lifetime > 5,000 hours (pre-aligned tungsten-halogen source)
Sample Presentation Rotating sample stage; standard powder cup, large-volume cup (forage/pellets), liquid cuvette (30–100 g capacity)
Chemometrics Algorithms Quantitative: PLS / LPLS (Local Partial Least Squares); Qualitative: DPLS (Discriminant Partial Least Squares)
Dimensions (W × D × H) 365 × 295 × 157 mm
Chassis Weight Approx. 18 kg
Data Interfaces & Networking USB / Ethernet; supports real-time remote monitoring, cloud backup, and enterprise LIMS/ERP integration

Enterprise System Integration: Centralized networking software enables automatic spectral uploading, cloud model updates, and fleet-wide instrument diagnostics. Direct API interfaces are readily available for integration into enterprise LIMS, ERP, and SAP environments.

View full details
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

Frequently Asked Questions

How can I contact you?

Feel free to call us T+86 189-6516-4839
or email  sales@nwspec.com to:

• Place an order
• Ask for a quote
• Or if you have any other questions

You will always get a live person here at NWSPEC; never an automated system! 

We are open from 6:00AM - 7:00PM Eastern Time, Monday - Friday. 

Where can I find application notes?

If you have any questions regarding the application notes, or can't find the one you are looking for, please contact Sales at sales@nwspec.com



Do you have instructional manuals for your instruments to download?

Yes, we have instructional manuals for our instruments. They can be found on https://nwspec.com/pages/resource .

If you don't see the one you are looking for, please contact: sales@nwspec.com



Contact form

Track Order

Please enter your tracking number below: