Skip to product information
1 of 1

NWSPEC

SR40 Versatile Miniature Fiber Optic Spectrometer | 200–1100 nm

SR40 Versatile Miniature Fiber Optic Spectrometer | 200–1100 nm

SR40 Micro Optical Fiber Spectrometer

Application Order Guide

Plug-and-play compact spectrometer for water analysis, biomedical, environmental, and industrial testing. Wide spectral range with high UV sensitivity.

SR40 Key Advantages

Wide Range 200-1100nm coverage with high UV sensitivity for comprehensive analysis.
Low Temperature Drift 0.1 pixel/°C stability. Auto dark correction for reliable measurements.
Low Noise <50RMS (ADmax=65535). SNR: 430:1. Ideal for weak signal detection.
Multi-Communication USB 2.0, RS232, RS485. 16-pin extended port with external trigger.
1
Select Application Type

Match your measurement need to the recommended system configuration

Water Analysis / Quality
Ultramicro spectrophotometry for water quality monitoring, COD, and pollutant detection in laboratory and field.
High UV sensitivity for organic detectionApplications: Drinking water, wastewater, environmentalRecommended: UV-Vis + D2/W + 4-Way Cuvette Holder
Smoke / Flue Gas Detection
Optical gas cell configuration for industrial exhaust, combustion analysis, and atmospheric monitoring.
Long pathlength gas cell for ppm sensitivityApplications: Power plants, automotive exhaust, industrial stacksRecommended: UV-NIR + D2/W + Optical Gas Cell
Biomedical / Life Science
DNA/RNA quantification, protein analysis, and pharmaceutical testing with high precision and repeatability.
Low noise: <50RMS for weak signal detectionApplications: Biotech, drug development, clinical labsRecommended: UV-Vis + D2/W + Cuvette Holder + Advanced Software
Education / Research
Teaching and research platform for universities. Complete with standard solutions and flexible configurations.
Plug-and-play operation. Multiple communication optionsApplications: Teaching labs, method developmentRecommended: UV-Vis + D2/W + Cuvette Holder + Basic Software
Food / Pharmaceutical
Quality control and composition analysis for food safety, drug purity, and additive detection.
High sensitivity for trace component detectionApplications: Food safety, pharma QC, additive analysisRecommended: UV-Vis + D2/W + 4-Way Cuvette + Advanced Software
Reflection / Transmission Testing
Optical property measurement for coatings, filters, lenses, and materials across UV-Vis-NIR.
Transmission test bracket + reflection test bracketApplications: Optical coatings, glass, plastic filmsRecommended: UV-NIR + D2/W + Transmission Bracket + Reflection Bracket
Lens / Optical Component Testing
Spectral transmission and reflectance measurement for lenses, filters, and optical devices.
Precision positioning with motor controlApplications: Eyewear, camera lenses, optical filtersRecommended: UV-Vis + D2/W + Motor Control + Transmission Bracket
Automotive Exhaust Detection
Emission monitoring for vehicle testing stations and engine development labs.
Fast response for real-time exhaust analysisApplications: Vehicle inspection, engine R&DRecommended: UV-NIR + D2/W + Optical Gas Cell + Trigger Control
2
Select Spectrometer Core

Detector type and wavelength range

Configuration Specifications Code Best For
UV-Vis (200-850nm) 2048-pixel CMOS linear sensor. Resolution ~0.8nm FWHM. Integration: 0.4ms-1000ms. SNR: 430:1. Dynamic range: 1000:1. UVV Water analysis, biomedical, education
UV-NIR (200-1100nm) 2048-pixel CMOS linear sensor. Resolution ~1.2nm FWHM. Extended NIR sensitivity. Integration: 0.4ms-1000ms. UVN Full-range analysis, smoke, automotive exhaust
High Resolution (UV-Vis) 2048-pixel CMOS with enhanced resolution. ~0.17nm wavelength resolution. ~0.8nm optical resolution. Maximum precision. HRS Lens testing, precision research, laser characterization
Optical Platform Note All configurations use F/4 crossed Czerny-Turner optical path. Focal length options: 70mm or 90mm. Standard slit: 60μm (customizable). Fiber interface: SMA905, 0.22NA. Low temperature drift: 0.1 pixel/°C.
3
Select Light Source

Illumination matched to your wavelength range and application

Source Specifications Code Best For
Deuterium + Tungsten (D2/W) Full UV-Vis-NIR coverage: 200-1100nm. Output stability: ±0.5%. Combined broad-spectrum output for transmission/absorbance. D2W Water analysis, biomedical, general spectroscopy
Xenon Source (Pulsed) High-intensity UV-Vis pulsed output. Ideal for fluorescence, time-resolved, and weak signal measurements. XEN Fluorescence, flash photolysis, biomedical research
LED Source (Visible) Stable visible output: 400-700nm. Lifetime: >50,000 hours. Low power consumption. Fast warm-up. LED Colorimetry, portable systems, teaching labs
Tungsten-Halogen (Vis-NIR) Economical visible to NIR: 350-2500nm. High output in NIR region. Stable thermal output for reflectance. THL Reflectance, NIR analysis, transmission testing
4
Select Fiber & Sampling Accessories

Probes, optics, and interfaces for your sample type

Standard Fiber Bundle
General-purpose fiber optic cable for standard laboratory and industrial setups.
Core diameter: 400μm, 600μm, or 1000μmLength: 1m, 2m, or customConnector: SMA905Code: FIB
Reflection / Back Scatter Probe
Y-type probe for diffuse reflectance and back scatter measurements on solid samples.
6-around-1 fiber configurationOptional focusing lens tipBest for: Coatings, powders, solidsCode: RFP
Cuvette Holder
Standard cuvette holder for liquid absorption and transmission measurements.
Pathlength: 10mm standard cuvetteInterface: Fiber-coupledBest for: Water, biochemical, pharmaceuticalCode: CUV
4-Way Cuvette Holder
Multi-position cuvette holder for parallel sample measurement and automated batch analysis.
Capacity: 4 cuvettes simultaneouslyInterface: Fiber-coupled with switchingBest for: High-throughput screening, water batch testingCode: C4W
Transmission Test Bracket
Precision fixture for transmission measurement of filters, lenses, films, and optical components.
Adjustable sample positionCompatible with motor control for automated scanningBest for: Lens testing, filter characterizationCode: TTB
Reflection Test Bracket
Standard white plate and reflection fixture for diffuse reflectance calibration and measurement.
Includes PTFE standard white plateReflectance: >95% across UV-Vis-NIRBest for: Reflectance calibration, color standardsCode: RTB
Optical Gas Cell
Long pathlength gas cell for smoke, exhaust, and atmospheric gas analysis.
Pathlength: Multiple options availableMaterial: Corrosion-resistant housingBest for: Flue gas, automotive exhaust, air qualityCode: OGC
Optical Attenuator
Adjustable neutral density filter for controlling light intensity and preventing detector saturation.
Attenuation: Variable or fixed ND filtersMount: Standard optical mountBest for: High-intensity sources, sensitivity adjustmentCode: ATT
Motor Control System
High-precision motor with control board for automated sample positioning and scanning.
Motor: High-precision stepper motorControl: Motor control board + trigger control boardBest for: Lens scanning, automated testingCode: MOT
Trigger Control Board
External trigger interface for synchronized measurement with external events and devices.
Interface: 16-pin extended portFunction: External trigger input/outputBest for: Automated systems, production line integrationCode: TCB
Integrating Sphere
Uniform light collection for total flux, diffuse reflectance, and color measurements.
Diameter: 38mm or 50mmCoating: PTFE (Spectralon equivalent)Best for: LED testing, color analysis, reflectanceCode: ISP
Immersion / Dip Probe
Submersible probe for direct liquid transmission and online water monitoring.
Pathlength: 2mm, 5mm, or 10mmMaterial: Stainless steel / HastelloyBest for: Online water analysis, process streamsCode: DIP
5
Select Software Package

Control and analysis software level

Package Features Code Best For
Basic Control Real-time spectral display, data acquisition, basic math (smoothing, derivative), export to CSV/TXT/SPC. Auto-dark correction. BAS Standard laboratory use, teaching, basic QC
Advanced Analysis Full chemometrics: PLS, PCA, MLR. Quantitative analysis. Custom method builder. Report generation. Multi-communication support. ADV Water analysis, biomedical, pharmaceutical QC
SDK / API Full hardware control API. Cross-platform: C++, C#, Python, LabVIEW. Example code and documentation included. OEM licensing. 16-pin extended port with trigger control. SDK System integrators, OEM partners, automated systems
Operating System Support Software compatible with Windows, Android, Linux, and Wince. Communication interfaces: USB 2.0, RS232, RS485. Extended 16-pin port with external trigger capability. Auto dark correction standard.
6
Model Naming Reference

How to construct your complete order code

Position Component Available Codes
Base Platform SR40
1 Application Type WAT / SMK / BIO / EDU / FPH / RFT / LEN / AEX
2 Spectrometer UVV / UVN / HRS
3 Light Source D2W / XEN / LED / THL
4 Fiber / Accessory FIB / RFP / CUV / C4W / TTB / RTB / OGC / ATT / MOT / TCB / ISP / DIP
5 Software BAS / ADV / SDK
EXAMPLE CONFIGURATION
SR40-WAT-UVV-D2W-C4W-ADV
Water analysis — UV-Vis spectrometer — Deuterium/Tungsten source — 4-Way Cuvette Holder — Advanced analysis software
EXAMPLE CONFIGURATION
SR40-SMK-UVN-D2W-OGC-SDK
Smoke detection — UV-NIR spectrometer — Deuterium/Tungsten source — Optical Gas Cell — SDK for system integration
EXAMPLE CONFIGURATION
SR40-LEN-HRS-D2W-TTB-MOT-ADV
Lens testing — High-Resolution spectrometer — Deuterium/Tungsten source — Transmission Test Bracket + Motor Control — Advanced software
Lead Time Standard configurations: 2 weeks from order confirmation. Custom builds and OEM projects may require additional time — confirm with sales when ordering.
Customization & OEM Services Special wavelength ranges, resolution requirements, mechanical configurations, and private labeling are available upon request. Contact our technical team to discuss custom builds and OEM integration support.
Technical Support Not sure which configuration matches your application? Send your measurement requirements (sample type, wavelength range, environment) to our team for a recommended build.

Request a Quotation

Provide your configuration code or application requirements. Our team will confirm specifications, pricing, and lead time (typically 2 weeks) within 24 hours.

Contact Sales

View full details
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

Frequently Asked Questions

How can I contact you?

Feel free to call us T+86 189-6516-4839
or email  sales@nwspec.com to:

• Place an order
• Ask for a quote
• Or if you have any other questions

You will always get a live person here at NWSPEC; never an automated system! 

We are open from 6:00AM - 7:00PM Eastern Time, Monday - Friday. 

Where can I find application notes?

If you have any questions regarding the application notes, or can't find the one you are looking for, please contact Sales at sales@nwspec.com



Do you have instructional manuals for your instruments to download?

Yes, we have instructional manuals for our instruments. They can be found on https://nwspec.com/pages/resource .

If you don't see the one you are looking for, please contact: sales@nwspec.com



Contact form

Track Order

Please enter your tracking number below: