Skip to product information
1 of 1

NWSPEC

Compact 160 L Laboratory Glassware Washer

Compact 160 L Laboratory Glassware Washer

NWSPEC S-SERIES | Laboratory Glassware Washing

VitroWash 160S

Compact 160 L Laboratory Glassware Washer

A compact front-loading laboratory glassware washer with a solid door, standard drying, programmable washing, and application-specific basket configurations for routine laboratory workloads.

Model-Specific Configuration & Quotation

The washing system is configured around your glassware, residues, quantity per cycle, basket requirements, and installation conditions. NWSPEC confirms the final loading system, included items, options, price, and delivery schedule in the written quotation.

160 L
Chamber capacity
Solid
Door configuration
Standard
Drying configuration
8.5 kW
Total power

Key Operating Features

Programmable Washing

A touch panel with LCD provides access to 30 preset programs and 100 user-programmable programs for repeatable laboratory washing routines.

Adjustable Temperature and Drying

Wash temperature is adjustable from ambient to 93 °C in 1 °C increments. Drying time is adjustable from 1 to 300 minutes in 1-minute increments.

Application-Specific Loading

The front-loading chamber uses a drop-down door. Baskets, racks, or injectors are selected according to glassware type, dimensions, quantity, and loading pattern.

Data Transfer and Remote Monitoring

USB supports program updates and record transfer. LAN remote monitoring is included, and an optional printer can be specified in the quotation.

Is VitroWash 160S the Right Fit?

Use these checks as an initial guide. Final model selection depends on glassware dimensions, loading pattern, residue requirements, and the required basket configuration.

01   Routine glassware loads fit within a 160 L chamber.
02   The 1260 mm overall height suits the available installation space.
03   A solid door and standard drying meet the laboratory workflow.
Need another configuration?
Choose the VitroWash 220S for additional capacity with the same door and drying configuration. Choose the 220V or 280V when a vision door and HEPA-filtered drying are required.

VitroWash 160S Specifications

Chamber capacity 160 L
Door Solid
Drying Standard
Dimensions, L×W×H 635×735×1260 mm
Weight 170 kg
Pump flow 2×500 L/min
Washing pump 2×0.9 kW
Total power 8.5 kW
Water consumption 13 L/phase
Electrical supply 220 V AC, 50 Hz
Heating power 4 kW
Drying power 2.5 kW
Power supply cable 3 m; 3 × 4.0 mm²
Programs 30 preset; 100 user-programmable
Control interface Touch panel with LCD
Wash temperature Ambient–93 °C; adjustable in 1 °C increments
Drying time 1–300 min; adjustable in 1 min increments
Shell / main material 304 / 316L stainless steel
Loading configuration Front loading; drop-down door
Basket configuration Selected according to glassware type, size, and loading requirement
Data and service USB program updates and record transfer
Monitoring / options LAN remote monitoring; optional printer

Water consumption is stated per washing phase. Total consumption depends on the selected program. Configuration-specific details remain subject to the final quotation.

How to Order VitroWash 160S

A complete enquiry helps NWSPEC confirm the washer, loading system, installation requirements, and commercial scope.

1
Confirm the Model and Quantity

Select VitroWash 160S with its 160 L chamber, solid door, and standard drying. State the number of washers required.

2
Define Glassware and Basket Requirements

List glassware types, dimensions, quantity per cycle, and residues. Identify narrow-neck, volumetric, delicate, or other items requiring dedicated racks or injectors.

3
Check Installation Conditions

Confirm the available space for 635×735×1260 mm, the 220 V AC / 50 Hz supply, 8.5 kW total power, inlet water, drainage, and ventilation. Check local electrical requirements before ordering.

4
Review the Quotation and Confirm the Order

Provide the delivery destination, accessories, documentation needs, and target schedule. NWSPEC will confirm the final scope, included items, price, lead time, trade terms, and agreed installation or training support in writing.

Information to Include with Your Enquiry

Subject: VitroWash 160S Quotation Enquiry

Company / laboratory:
Contact person and work email:
Delivery country and city:
Required model and quantity: VitroWash 160S / quantity to be confirmed
Glassware types and dimensions:
Quantity per washing cycle:
Residues or application details:
Basket, rack, or injector requirements:
Installation space and utilities:
Optional printer or other accessory requirements:
Required documents, installation, or training:
Target delivery schedule:

Model and Ordering Questions

Does VitroWash 160S include HEPA-filtered drying?
No. The VitroWash 160S has a solid door and standard drying. For a double-glazed vision door and HEPA-filtered drying, consider the VitroWash 220V or 280V.
How are baskets and racks selected?
Baskets are configured according to glassware type, dimensions, quantity per cycle, and loading pattern. Include representative glassware lists or drawings with your enquiry so the loading system can be reviewed before quotation.
How much water does this model use?
The stated water consumption is 13 L/phase. This is consumption per washing phase, not necessarily the total for a complete program. Overall use depends on the selected washing sequence.
What should I confirm before placing the order?
Confirm the model, quantity, glassware and basket schedule, electrical and water services, installation space, delivery destination, required documents, optional accessories, and the agreed installation or training scope. Final specifications and commercial terms should be stated in the written quotation.

Request VitroWash 160S Quotation

Send your glassware list, quantity per cycle, basket requirements, installation conditions, and delivery destination for a configured technical and commercial proposal.

Email: sales@nwspec.com
Address: Xiongan Pilot Free Trade Zone, Hebei, China

NWSPEC VitroWash 160S | Laboratory glassware washing system configured to the confirmed application.

عرض التفاصيل كاملة
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

الأسئلة الشائعة

كيف يمكنني التواصل معك؟

لا تتردد في الاتصال بنا T+86 189-6516-4839
أو أرسل بريدًا إلكترونيًا إلى sales@nwspec.com من أجل:

• تقديم طلب
• طلب عرض أسعار
• أو إذا كان لديك أي أسئلة أخرى

ستتحدث دائمًا مع شخص حقيقي هنا في NWSPEC؛ ليس نظامًا آليًا أبدًا!

نحن مفتوحون من الساعة 6:00 صباحًا حتى 7:00 مساءً بالتوقيت الشرقي، من الاثنين إلى الجمعة.

أين يمكنني العثور على ملاحظات التطبيق؟

إذا كانت لديك أي أسئلة بخصوص ملاحظات التطبيق، أو لم تتمكن من العثور على ما تبحث عنه، يرجى الاتصال بقسم المبيعات على sales@nwspec.com



هل لديكم أدلة إرشادية قابلة للتنزيل لآلاتكم؟

نعم، لدينا كتيبات إرشادية لأدواتنا. يمكن العثور عليها على https://nwspec.com/pages/resource.

إذا لم تجد الكتيب الذي تبحث عنه، يرجى الاتصال على: sales@nwspec.com



نموذج الاتصال

Track Order

Please enter your tracking number below: