Skip to product information
1 of 7

NWSPEC

Fully Automated QuEChERS Sample Preparation System

Fully Automated QuEChERS Sample Preparation System

Fully Automated QuEChERS Sample Preparation System

Walkaway automation from sample handling to clean extract collection. Minimize manual transfers, improve workflow consistency, and maintain full process traceability.

48
50 mL sample tube positions
64
Autosampler vial positions
8
Independent nitrogen evaporation channels

Why Automate Your QuEChERS Workflow

Manual QuEChERS workflows involve multiple hands-on steps, including sample preparation, solvent addition, salt dispensing, mixing, centrifugation, extract transfer, dispersive solid-phase extraction, evaporation, filtration, and vial preparation.

Each manual step can introduce variability, contamination risk, and documentation gaps. Automation helps laboratories standardize preparation, reduce repetitive pipetting, and improve workflow traceability.

With automated sample preparation:

Load samples, select the method, start the run, and collect prepared extracts for downstream analysis.

What the System Does

1
Load and Handle Samples

Accommodates up to 48 × 50 mL sample tubes for automated batch processing.

2
Extract

Programmable solvent dispensing and mixing for repeatable extraction workflows.

3
Add Salts and Sorbents

10 independent solid-dosing reservoirs with dosing precision of ≤3 mg.

4
Centrifuge

Processes up to 8 tubes at speeds of up to 10,000 rpm. Refrigerated centrifugation is provided as standard.

5
Clean Up

Automated dispersive solid-phase extraction using configurable sorbent combinations such as PSA, C18, GCB, and Florisil.

6
Evaporate

8 independent nitrogen evaporation channels with near-dry detection at ≤30 μL.

7
Filter and Collect

60 filtration positions with 4-channel simultaneous filtration and clog detection. Prepared extracts are collected in 64 autosampler vial positions.

Key Features and Specifications

Sample capacity 48 × 50 mL tubes
Autosampler vial capacity 64 positions
Solid dosing 10 independent reservoirs, ≤3 mg precision
Centrifugation 8 tubes, up to 10,000 rpm, refrigerated standard
Nitrogen evaporation 8 independent channels, near-dry detection ≤30 μL
Filtration 60 positions, 4-channel simultaneous filtration, clog detection
Workflow control Programmable methods and process parameters
Data export CSV, PDF, and LIMS-compatible formats
MS compatibility Suitable for LC-MS/MS and GC-MS/MS workflows

Applications

Food and Agriculture

Sample preparation for pesticide residue analysis in fruits, vegetables, grains, tea, and other agricultural products.

Environmental Testing

Extraction and cleanup workflows for soil, sediment, water, and other environmental matrices.

Feed Safety

Automated preparation of feed, feed additives, and ingredient samples for multi-residue analysis.

Pharmaceuticals and Botanical Products

Sample preparation for pesticide residue and related analytical workflows involving botanical and pharmaceutical products.

Contract Testing and Research Laboratories

Flexible automation for laboratories processing diverse sample matrices and developing or transferring analytical methods.

Compliance and Data Integrity

  • Audit trail records workflow steps, parameters, and timestamps
  • User access control and event logging
  • CSV, PDF, and LIMS-compatible data export
  • Traceable sample and process identification
  • Touch-screen user interface

Common Questions

What is the sample capacity?
The system accommodates up to 48 × 50 mL sample tubes. It also provides 64 autosampler vial positions for prepared extract collection.
What are the centrifugation capabilities?
The centrifuge processes up to 8 tubes at speeds of up to 10,000 rpm. Refrigerated centrifugation is provided as standard.
How does the solid-dosing system work?
The system uses 10 independent solid-dosing reservoirs with dosing precision of ≤3 mg. This supports flexible salt and sorbent combinations for method development.
What are the filtration specifications?
The filtration module provides 60 positions, 4-channel simultaneous filtration, and clog detection.
Does it work with LC-MS/MS and GC-MS/MS?
Yes. Prepared extracts can be used with LC-MS/MS and GC-MS/MS workflows, subject to instrument compatibility and laboratory-validated methods.
What is the nitrogen evaporation capacity?
Nitrogen evaporation is performed through 8 independent channels with near-dry detection at ≤30 μL.
Can I develop custom methods?
Yes. Programmable workflow parameters and independent solid-dosing reservoirs support method development and customization for different sample matrices.
Important Notice

Performance may depend on the sample matrix, consumables, selected method, instrument configuration, and operating conditions. Each laboratory is responsible for method development, verification, validation, and compliance with applicable local requirements before routine use.

Custom method development and application consulting available.

Compatible with LC-MS/MS and GC-MS/MS analytical workflows.

عرض التفاصيل كاملة
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

الأسئلة الشائعة

كيف يمكنني التواصل معك؟

لا تتردد في الاتصال بنا T+86 189-6516-4839
أو أرسل بريدًا إلكترونيًا إلى sales@nwspec.com من أجل:

• تقديم طلب
• طلب عرض أسعار
• أو إذا كان لديك أي أسئلة أخرى

ستتحدث دائمًا مع شخص حقيقي هنا في NWSPEC؛ ليس نظامًا آليًا أبدًا!

نحن مفتوحون من الساعة 6:00 صباحًا حتى 7:00 مساءً بالتوقيت الشرقي، من الاثنين إلى الجمعة.

أين يمكنني العثور على ملاحظات التطبيق؟

إذا كانت لديك أي أسئلة بخصوص ملاحظات التطبيق، أو لم تتمكن من العثور على ما تبحث عنه، يرجى الاتصال بقسم المبيعات على sales@nwspec.com



هل لديكم أدلة إرشادية قابلة للتنزيل لآلاتكم؟

نعم، لدينا كتيبات إرشادية لأدواتنا. يمكن العثور عليها على https://nwspec.com/pages/resource.

إذا لم تجد الكتيب الذي تبحث عنه، يرجى الاتصال على: sales@nwspec.com



نموذج الاتصال

Track Order

Please enter your tracking number below: