Skip to product information
1 of 5

NWSPEC

HPLC Consumables & Parts

HPLC Consumables & Parts

NWSPEC HPLC Consumables & Parts

High-Performance Liquid Chromatography — Accessories, Columns, and Replacement Components

Compatible with: Agilent Waters Thermo Fisher Shimadzu PerkinElmer
Direct-equivalent performance to major OEM brands. Request a quote for distributor pricing, bulk orders, or OEM cross-reference verification. No minimum order quantities.
Product / Specification / OEM Cross-Reference NWSPEC PN Replaces OEM P/N

Tubing & Connections

Biocompatible PEEK and high-pressure stainless steel
PEEK Tubing Assembly
Column-to-detector connection. ID 0.13mm, length 1m. Includes two integrated finger-tight fittings. Biocompatible, metal-free flow path.
Compatible: Agilent 1290/1260 Infinity II, Waters Alliance/e2695, Thermo Vanquish, Shimadzu Nexera
803-822-1
Agilent 5067-4781
Waters WAT005996
Thermo 6040.2365
Silicone Waste Tubing Assembly
Waste drainage connection from drip tray to waste container. Flexible chemical-resistant silicone. 1.6mm ID, 2m length with fittings.
Compatible: Universal fit — Agilent, Waters, Shimadzu, Thermo standard waste ports
803-822-2
Agilent 5062-2463
Waters WAT005997
Shimadzu 228-18881-91
SS High-Pressure Tubing — 0.25mm ID
Stainless steel quick-connect assembly. ID×L 0.25×500mm. Connects solvent delivery pump to autosampler. Includes pressure screw and ferrule set. Rated 600 bar.
Compatible: Agilent 1290/1260, Waters Alliance, Thermo UltiMate 3000, Shimadzu Prominence
803-822-3
Agilent 5067-4783
Waters 700002636
Thermo 6041.2300
SS High-Pressure Tubing — 0.13mm ID
Stainless steel quick-connect assembly. ID×L 0.13×500mm. Connects autosampler to analytical column. Includes pressure screw and ferrule set. Rated 600 bar.
Compatible: Agilent 1290/1260, Waters Alliance, Thermo Vanquish, Shimadzu Nexera
803-822-4
Agilent 5067-4784
Waters 700002637
Thermo 6041.2310

Detector Light Sources

Deuterium and tungsten-halogen lamps
Deuterium Lamp — R9500 Series
High-intensity UV detector lamp with pre-aligned socket. 2000+ hour lifetime. Stable spectral output 190-600nm. Direct-fit replacement for R9500 detector modules.
Compatible: Agilent G1314D/G1314E (VWD), Waters 2489/2998, Thermo VWD-3000/3400
823-802-1
Agilent 2140-0820
Waters 201000281
Thermo 6074.2000
Shimadzu 228-37401-91

Solvent Inlet Filtration

Glass and stainless steel filter assemblies
10μm Solvent Inlet Filter
Stainless steel filter head with 10μm porosity frit. Connects to solvent delivery tubing inside reservoir. Prevents particulate contamination of pump and column. 1/8" OD tubing connection.
Compatible: Agilent 1260/1290, Waters Alliance, Thermo UltiMate, Shimadzu Prominence/Nexera
803-823
Agilent 5041-2168
Waters WAT005998
Thermo 6040.5100
Shimadzu 228-35601-91

Autosampler Injection Systems

Needle, seat, and seal assemblies
HPLC Needle Assembly — Sco Type
Standard-flow injection needle with integrated seat and seal. For conventional HPLC autosamplers (≤400 bar). Precision-ground stainless steel needle with PEEK seal. Includes alignment tool.
Compatible: Agilent 1260/1290 standard autosampler, Waters 717/2695, Shimadzu SIL-20A
803-825-1
Agilent G1313-87201
Waters WAT005999
Shimadzu 228-41001-91
UHPLC Needle Assembly — Leo Type
Small-bore injection needle for ultra-high-pressure autosamplers (≤1300 bar). Hardened stainless steel with reinforced PEEK seal. Optimized for low-dispersion, high-throughput workflows. Includes alignment tool.
Compatible: Agilent 1290 Infinity II, Waters ACQUITY UPLC, Thermo Vanquish, Shimadzu Nexera X2/X3
803-825-2
Agilent G4226-87201
Waters 700002654
Thermo 6040.2405
Shimadzu 228-41002-92

Cetus C18 P Reversed-Phase Columns

Analytical to preparative · High-purity silica · USP L1
Cetus C18 P — 5μm, 4.6×250mm
Standard analytical column. High-purity spherical silica, monomeric C18 bonding, endcapped. 120Å pore size, 15% carbon load. Ideal for method development and routine pharmaceutical QC.
Equivalent to: Agilent ZORBAX Eclipse Plus C18, Waters XBridge C18, Thermo Hypersil GOLD, Shimadzu Shim-pack VP-ODS
803-815-6
Agilent 959990-902
Waters 186003113
Thermo 25005-254630
Shimadzu 228-34937-91
Cetus C18 P — 5μm, 4.6×150mm
Standard analytical column. Shorter format for faster analysis with maintained resolution. Same bonding chemistry as 250mm version. For high-throughput screening where full resolution is not required.
Equivalent to: Agilent ZORBAX Eclipse Plus C18, Waters XBridge C18, Thermo Hypersil GOLD
803-815-7
Agilent 959993-902
Waters 186003114
Thermo 25005-154630
Cetus C18 P — 3μm, 4.6×150mm
Higher efficiency analytical column. 3μm spherical silica for improved plate count and resolution. For complex sample matrices — herbal medicines, food safety, environmental extracts.
Equivalent to: Agilent ZORBAX SB-C18, Waters XSelect CSH C18, Thermo Accucore C18
803-815-8
Agilent 883975-902
Waters 186005292
Thermo 17326-154630
Cetus C18 P — 3μm, 4.6×100mm
Fast analysis column. 3μm particles in short format for high-throughput screening with maintained resolution. 50% faster run times vs. 150mm with 85% resolution retention.
Equivalent to: Agilent Poroshell 120 EC-C18, Waters XSelect CSH C18, Thermo Accucore XL C18
803-815-9
Agilent 699975-902
Waters 186005293
Thermo 17326-104630
Cetus C18 P — 1.8μm, 2.1×100mm
UHPLC column. Sub-2μm fully porous silica. 2.1mm narrow bore for MS-compatible flow rates (0.2-0.5 mL/min). Maximum efficiency for complex separations — proteomics, metabolomics, impurity profiling.
Equivalent to: Agilent ZORBAX RRHD Eclipse Plus, Waters ACQUITY BEH C18, Thermo Accucore Vanquish
803-815-10
Agilent 959758-902
Waters 186002352
Thermo 27103-102130
Cetus C18 P — 1.8μm, 2.1×50mm
Ultra-short UHPLC column. 1.8μm particles for rapid analysis (< 3 min run times). Ideal for fast QC screening, stability-indicating assays, and high-throughput method transfer.
Equivalent to: Agilent Poroshell 120 SB-C18, Waters ACQUITY BEH C18, Thermo Accucore Vanquish
803-815-11
Agilent 857700-902
Waters 186002353
Thermo 27103-052130
Cetus C18 P — 1.8μm, 2.1×150mm
Extended UHPLC column. Maximum resolution for demanding separations. Highest peak capacity in Cetus line. For complex natural products, peptide mapping, and forced degradation studies.
Equivalent to: Agilent ZORBAX RRHD Eclipse Plus, Waters ACQUITY BEH C18, Thermo Accucore Vanquish
803-815-12
Agilent 959759-902
Waters 186002354
Thermo 27103-152130
Cetus C18 P — 5μm, 19×250mm
Semi-preparative column. 19mm ID for 10-50 mg sample loading. High-purity silica with same bonding chemistry as analytical scale. For compound isolation and purification workflows.
Equivalent to: Agilent Prep-C18, Waters XBridge Prep C18, Thermo Hypersil Prep
803-815-13
Agilent 977250-102
Waters 186002477
Thermo 31105-254019
Cetus C18 P — 10μm, 19×250mm
Preparative column. Large 10μm particles for lower backpressure at high flow rates. 100-500 mg loading capacity. For initial crude separations and flash-to-prep scale-up.
Equivalent to: Agilent Prep-C18, Waters XBridge Prep C18, Shimadzu Shim-pack Prep-ODS
803-815-14
Agilent 977251-102
Waters 186002478
Shimadzu 228-34951-91
Cetus C18 P — 3μm, 10×250mm
High-efficiency preparative column. 3μm particles balance resolution and loading capacity. 20-100 mg sample load. For purified fraction collection and intermediate-scale isolation.
Equivalent to: Agilent PrepHT C18, Waters XSelect Prep CSH C18, Thermo Hypersil GOLD Prep
803-815-15
Agilent 977252-102
Waters 186005376
Thermo 31103-254010
NWSPEC Scientific Instrumentation
HPLC  — Compatible with Agilent, Waters, Thermo Fisher, Shimadzu, and PerkinElmer consumables.
×

Request a Quote

PN: 803-822-1

 

عرض التفاصيل كاملة
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

الأسئلة الشائعة

كيف يمكنني التواصل معك؟

لا تتردد في الاتصال بنا T+86 189-6516-4839
أو أرسل بريدًا إلكترونيًا إلى sales@nwspec.com من أجل:

• تقديم طلب
• طلب عرض أسعار
• أو إذا كان لديك أي أسئلة أخرى

ستتحدث دائمًا مع شخص حقيقي هنا في NWSPEC؛ ليس نظامًا آليًا أبدًا!

نحن مفتوحون من الساعة 6:00 صباحًا حتى 7:00 مساءً بالتوقيت الشرقي، من الاثنين إلى الجمعة.

أين يمكنني العثور على ملاحظات التطبيق؟

إذا كانت لديك أي أسئلة بخصوص ملاحظات التطبيق، أو لم تتمكن من العثور على ما تبحث عنه، يرجى الاتصال بقسم المبيعات على sales@nwspec.com



هل لديكم أدلة إرشادية قابلة للتنزيل لآلاتكم؟

نعم، لدينا كتيبات إرشادية لأدواتنا. يمكن العثور عليها على https://nwspec.com/pages/resource.

إذا لم تجد الكتيب الذي تبحث عنه، يرجى الاتصال على: sales@nwspec.com



نموذج الاتصال

Track Order

Please enter your tracking number below: