Skip to product information
1 of 1

NWSPEC

Research Confocal Raman Microscope

Research Confocal Raman Microscope

Ram-M400 / Ram-M800 Research Confocal Raman Microscope

Flagship confocal Raman platform for materials research, 2D materials and phonon physics, pharmaceutical polymorphism, operando batteries, label-free bio-imaging, and cultural-heritage analysis.

Spectral Resolution
< 0.5 cm⁻¹
0.02 cm⁻¹ repeatability (M800)
Excitation Lasers
Up to 4 Lasers
213–1064 nm auto-switching
Low-Wavenumber Cutoff
±5 cm⁻¹
Simultaneous Stokes / Anti-Stokes
Confocal Optics
True Pinhole + Slit
15–2000 µm continuous control

Real-World Application Scenarios

Scenario What You Are Trying to Do How Ram-M400 / M800 Solves It
2D materials & strain engineering Resolve adjacent phonon modes in graphene, MoS₂, h-BN; map strain at sub-cm⁻¹ level. 0.5 cm⁻¹ class resolution (M800) with 0.02 cm⁻¹ repeatability separates peaks that ordinary microscopes merge.
Lattice / low-frequency modes Measure shear and breathing modes close to the laser line. Ultra-low wavenumber module records Stokes / anti-Stokes simultaneously down to a ±5 cm⁻¹ cutoff.
Pharmaceutical polymorphism Distinguish crystal forms, confirm salt formation, check tablet uniformity. True confocal pinhole + slit (15–2000 µm) isolates pure material; Raman / fluorescence / absorption imaging maps the whole surface.
Operando batteries & electrochemistry Watch electrodes and SEI evolve inside a working cell. 3-electrode electrochemical cell (upright / vertical) plus heating-cooling stage (−15 to +55 °C) for in-situ Raman.
TERS & nanoscale Raman Push below the diffraction limit with an AFM tip. Detachable fiber TERS probe with built-in coaxial video couples to mainstream AFMs; platform is TERS-ready by design.
Fluorescent / coloured samples Get clean Raman from samples that swamp 532 nm systems. Up to 4 lasers chosen from 213–1064 nm with automatic filter switching — pick 633/785/1064 nm to defeat fluorescence.

Why It Fits Your Laboratory

The Ram-M400 and Ram-M800 represent NWSPEC's research-flagship tier: longer focal length, more lasers, deeper detector cooling, and a true pinhole + slit confocal path. Choose Ram-M400 for <0.8 cm⁻¹ resolution on a standard optical bench, or Ram-M800 when only <0.5 cm⁻¹ ultra-high resolution satisfies advanced phonon physics. Both share the same software, stages, and extension modules so accessories transfer across your laboratory.

Build Your Configuration — 3 Key Decisions

Decision 1 — Spectrometer Base: M400 vs. M800

Model Focal Length Resolution Recommended For
Ram-M400 400 mm < 0.8 cm⁻¹ Pharmaceutical, polymer and standard materials QC
Ram-M800 800 mm < 0.5 cm⁻¹ 2D materials, phonon physics, closely spaced vibrational peaks

Decision 2 — Laser Bay (Up to 4 Lasers)

Select up to 4 ultra-narrow-linewidth lasers from 213, 244, 257, 355, 405, 488, 532, 633, 785, 830, 850, and 1064 nm. Edge-filter sets switch automatically in software without manual optical alignment.

  • Materials & 2D: 532 nm + 633 nm (add 785 nm for fluorescent substrates)
  • Pharma & Biological: 785 nm (fluorescence suppression) + 532 nm reference
  • UV Photoluminescence: 355 nm or 405 nm UV configuration

Decision 3 — Detector Cooling & Specialized Modules

Choose deep-cooled TEC CCD at −70 °C (air-cooled) or −100 °C (water-cooled) for ultra-low dark noise. Add optional extensions: ultra-low wavenumber module (±5 cm⁻¹ cutoff), operando 3-electrode electrochemical cell, heating/cooling stage (−15 to +55 °C), or fiber TERS probe for AFM integration.

Key Specifications

Focal length Ram-M400: 400 mm · Ram-M800: 800 mm
Spectral resolution < 0.8 cm⁻¹ (M400) · < 0.5 cm⁻¹ (M800); repeatability 0.02 cm⁻¹
Gratings Up to 4 mounted, 150–4964 g/mm options, motorized switching
Spectral range Raman shift 50–9700 cm⁻¹; detector response 200–1100 nm
Ultra-low wavenumber Stokes / anti-Stokes simultaneous, down to ±5 cm⁻¹
Excitation lasers Up to 4 narrow-linewidth lasers (213–1064 nm); stability ≤0.24% RMS / 4h
Confocal optics True confocal pinhole + entrance slit, 15–2000 µm continuously adjustable
Detector TEC deep-cooled CCD (−70 °C air / −100 °C water); Si 3rd-order SNR >30:1
Sample stage Motorized XYZ, 75 × 50 × 30 mm, 0.5 µm repeatability, 50 nm step, auto-focus
Microscope Upright reflected brightfield; 5× / 10× / 20× / 50× LWD / 100× plan-achromatic
Software Raman/fluorescence/absorption imaging, auto-baseline removal, spectral library search

Frequently Asked Questions

Which model do I need — Ram-M400 or Ram-M800?

For routine high-resolution work (polymorph ID, materials QC), the M400 is ideal. If you analyze 2D materials, strain, or phonon physics where peaks sit less than 1 cm⁻¹ apart, choose the M800 for its 800 mm focal length and <0.5 cm⁻¹ resolution.

How many lasers can be installed, and can I add more later?

The optical bay accepts up to 4 lasers selected from 12 wavelengths, with automated software switching. The laser package is pre-configured during manufacturing to ensure perfect optical alignment.

How low in wavenumber can the system measure?

With the ultra-low wavenumber filter module, the system records Stokes and anti-Stokes scattering simultaneously down to a ±5 cm⁻¹ cutoff, ideal for lattice, shear, and breathing modes.

Can it support in-situ electrochemistry or AFM-TERS?

Yes. A 3-electrode upright/vertical electrochemical cell with temperature control (−15 to +55 °C) supports operando battery research, and a detachable fiber TERS probe connects directly to mainstream AFMs.

Get a Configuration Recommendation & Quote

Tell us your research application, laser wavelengths (from 213–1064 nm) and extension modules. NWSPEC will configure your Ram-M400 or Ram-M800 platform and provide a comprehensive quotation.

عرض التفاصيل كاملة
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

الأسئلة الشائعة

كيف يمكنني التواصل معك؟

لا تتردد في الاتصال بنا T+86 189-6516-4839
أو أرسل بريدًا إلكترونيًا إلى sales@nwspec.com من أجل:

• تقديم طلب
• طلب عرض أسعار
• أو إذا كان لديك أي أسئلة أخرى

ستتحدث دائمًا مع شخص حقيقي هنا في NWSPEC؛ ليس نظامًا آليًا أبدًا!

نحن مفتوحون من الساعة 6:00 صباحًا حتى 7:00 مساءً بالتوقيت الشرقي، من الاثنين إلى الجمعة.

أين يمكنني العثور على ملاحظات التطبيق؟

إذا كانت لديك أي أسئلة بخصوص ملاحظات التطبيق، أو لم تتمكن من العثور على ما تبحث عنه، يرجى الاتصال بقسم المبيعات على sales@nwspec.com



هل لديكم أدلة إرشادية قابلة للتنزيل لآلاتكم؟

نعم، لدينا كتيبات إرشادية لأدواتنا. يمكن العثور عليها على https://nwspec.com/pages/resource.

إذا لم تجد الكتيب الذي تبحث عنه، يرجى الاتصال على: sales@nwspec.com



نموذج الاتصال

Track Order

Please enter your tracking number below: