Skip to product information
1 of 1

NWSPEC

RamPalm1064 Handheld Raman Spectrometer | OEM/ODM | NWSPEC

RamPalm1064 Handheld Raman Spectrometer | OEM/ODM | NWSPEC

RamPalm1064 Handheld Raman Spectrometer

1064 nm handheld identification for high-fluorescence samples: pharmaceuticals, security screening, petrochemicals, archaeology, and chemical-agent detection. Available for standard deployment and custom OEM/ODM integration.

Why 1064 nm Excitation?

Most handheld Raman analyzers utilize 785 nm lasers, which often saturate from sample fluorescence when analyzing colored, dark, or impure chemicals. The RamPalm1064 features a narrow-linewidth 1064 nm laser (0.10 nm) that minimizes fluorescence excitation. Paired with a deep-cooled InGaAs detector (TEC down to −20 °C), it maintains high sensitivity and delivers crisp, conclusive spectra where standard 785 nm instruments fail.

How to Order — 3 Steps

Step 1 — Detection Mode: Routine or Trace

Mode What It Covers Choose If
Routine Identification (Standard) Hazardous chemicals, toxic compounds, drug precursors, and energetic materials in solid, powder, or liquid forms. Your primary targets are bulk or macro quantities.
Trace Detection (+ SERS Chips) Ultra-trace detection of toxic and hazardous liquids via Surface-Enhanced Raman Spectroscopy (SERS) test chips. You require detection of minute chemical residues at security checkpoints or forensics sites.

Step 2 — Target Spectral Library Packages

  • Public Security & Law Enforcement: Illicit narcotics, explosives, hazardous chemicals, and precursor substances.
  • Pharmaceutical Industry: Raw material identification, incoming excipient verification, and QA/QC release testing.
  • Petrochemical: Fuel classification, lubricants, additives, and solvent purity screening.
  • Custom Libraries: Proprietary compound database expansion created directly from your provided reference standards.

Step 3 — Connectivity & Workflow Capabilities

Standard integrated features include automated reporting in PDF, TXT, and EXCEL formats via removable storage or USB cable; dual-band Wi-Fi, Bluetooth, and USB 2.0 connectivity; USB Type-C rapid charging; and over 2 hours of continuous field operation per charge (−20 °C to 40 °C ambient range).

Recommended Deployment Example: RamPalm1064 + Trace Detection (SERS Chips) + Public Security Library + Automated PDF/EXCEL Reporting for airport and border security screening of suspect liquids, powders, and fluorescence-active dyed samples.

OEM & ODM Customization Services

Capability Customization Scope
Hardware & Enclosure Custom exterior chassis colors, private-label silk screening, custom optical sampling probes, and ruggedized carrying cases.
Software & SDK White-label GUI firmware, customized boot screens, and full API / communication SDK access for seamless system integration.
Proprietary Databases Factory pre-installation of client-specified Raman spectral databases with on-device hardware encryption.

Key Specifications

Model Designation RamPalm1064
Laser Excitation 1064 nm narrow-linewidth laser (0.10 nm); stability ≤ ±1%/60 min; 0–600 mW software-adjustable
Spectral Range 127–2000 cm⁻¹
Spectral Resolution 9–15 cm⁻¹
Detector Deep-cooled InGaAs detector (TEC cooled to −20 °C), high-throughput spectrograph
Supported Sample Forms Solid, powder, liquid, and SERS test chips
Manufacturing Services Standard direct supply, OEM white-labeling, and custom ODM hardware/software engineering
Battery Runtime ≥ 2 hours continuous operation; USB Type-C charging
Interfaces & Data Export Wi-Fi, Bluetooth, USB 2.0; export formats: PDF, TXT, EXCEL
Dimensions & Weight 221 × 113 × 46 mm · 2.5 kg
Operating Temperature −20 °C to 40 °C

Frequently Asked Questions

My sample is heavily colored or dark and fluoresces — will it work?

Yes. The 1064 nm excitation laser wavelength significantly suppresses fluorescence background, allowing clear identification of dark or dyed substances.

How does trace liquid detection work?

Select the trace mode with SERS chips. Applying a small droplet of liquid to the surface-enhanced chip amplifies the Raman signal by orders of magnitude for ultra-trace identification.

Can NWSPEC provide OEM branding or white-label units?

Yes. We offer complete OEM services including custom chassis colors, silk-screened logos, white-label UI firmware, and communication SDKs for industrial integrators.

Is the unit ruggedized for harsh field conditions?

Yes. Built to operate from −20 °C to 40 °C with battery life exceeding 2 hours, on-board reporting, and USB Type-C field charging.

Request an OEM/ODM Quote — RamPalm1064

Contact our engineering team to evaluate technical requirements, request volume pricing, or discuss customized OEM/ODM production and private-label integration.

عرض التفاصيل كاملة
Since 1993 30+ Years of Instrument Expertise
Reliable Manufacturer Manufacturing & Services
Ph.D. Founded Dr. Pingxin Wang, UT Austin
Advantages Price · Service · Speed · Technical · Data
Fast Shipping In-Stock Orders Ship Same Day

الأسئلة الشائعة

كيف يمكنني التواصل معك؟

لا تتردد في الاتصال بنا T+86 189-6516-4839
أو أرسل بريدًا إلكترونيًا إلى sales@nwspec.com من أجل:

• تقديم طلب
• طلب عرض أسعار
• أو إذا كان لديك أي أسئلة أخرى

ستتحدث دائمًا مع شخص حقيقي هنا في NWSPEC؛ ليس نظامًا آليًا أبدًا!

نحن مفتوحون من الساعة 6:00 صباحًا حتى 7:00 مساءً بالتوقيت الشرقي، من الاثنين إلى الجمعة.

أين يمكنني العثور على ملاحظات التطبيق؟

إذا كانت لديك أي أسئلة بخصوص ملاحظات التطبيق، أو لم تتمكن من العثور على ما تبحث عنه، يرجى الاتصال بقسم المبيعات على sales@nwspec.com



هل لديكم أدلة إرشادية قابلة للتنزيل لآلاتكم؟

نعم، لدينا كتيبات إرشادية لأدواتنا. يمكن العثور عليها على https://nwspec.com/pages/resource.

إذا لم تجد الكتيب الذي تبحث عنه، يرجى الاتصال على: sales@nwspec.com



نموذج الاتصال

Track Order

Please enter your tracking number below: